Category
- Uncategorized
- Access Control and Time Attendance System
- Accessories
- Addressable base
- Audio
- Cable
- Call Point
- Cameras
- Closed Circuit Television System (CCTV)
- Computer & Laptop
- Door controller
- Fire Alarm System
- Home Appliances
- Manual Callpoints
- Metal Detector
- Naso mask
- New Arrival
- Night Vision
- On Sale
- Security Alarm System
Popular
-
C-Tec FP 8 Zone Conventional Fire Alarm Panel-Ff388-2
₦125,000.00₦120,000.00 -
SOCA SL-130 Dead Bolt Lock ( All purpose type )
₦15,000.00₦13,000.00 -
SOCA SL-100D Dead Bolt Lock ( for automatic door)
₦18,000.00₦15,000.00 - SOCA SL 100A Dead Bolt ₦15,000.00
- Soca SD-30 Armored Door Loop
Tag Clouds
Gent VIG-LPC-EN Vigilon Loop Card (EN54) (2Km) for VIG1-24 and VIG1-72 Fire Alarm Control Panel
₦155,000.00
DESCRIPTION
Gent VIG-LPC-EN Vigilon Loop Card (EN54)
The VIG-LPC-EN is an additional Loop Card for Gent Vigilon Panels.
The new Loop Card is designed to fully comply with EN54-23 and is available on EN54 versions of the Vigilon range of panels. The increased power allows for up to 100 EN54-23 sensor-sounder-strobes on a 2km loop, managing up to 200 devices in total.
Gent VIG-LPC-EN Vigilon Loop Card
The Gent VIG-LPC-EN Vigilon Loop Card complies with EN54-23 fully and it is available on EN54 versions of the Vigilon range of panels. The increased power allows for up to 100 EN54-23 sensor-sounder-strobes on a 2km loop, managing up to 200 devices.
Benefits
- Improved efficiency with 2 times more alarm power with no loss of standby
- Supports up to 100 S-Quad Sensor-Sounder-VADs certified to EN54-23
- Supports the upgrade of existing Vigilon installations
FEATURES AND BENEFITS
Loop alarm current
The new loop card supports a higher loop load in alarm and delivers a higher capacity for EN54-23 compliant visual alarms devices. The maximum alarm load of 800mA is available ONLY with the new range of alarm devices. With any of the old range of alarm devices (S-Quad, S-Cubed) the maximum alarm load is limited to 400mA per loop.
Loop length
The loop card is capable of supporting loops in excess of 1km with a maximum length of 2km with 1.5mm2 cable. This is subject to loop population and distribution of sounders and visual alarm devices.
Alarm device distribution
A key factor affecting the loop length and alarm current capability of the loop card is the distribution of alarm devices on the loop. In some circumstances the new loop card may support fewer devices or loop lengths less than 2km. Reference should be made to the loop load calculations in the installation instructions and
by use of the Battery Standby and Loop Load Calculator Tool.
Validating loop length
The loop card will automatically measure (and display on the panel) the loop resistance of each loop on allocation. This will allow engineers to easily fulfil one of the required tasks for commissioning the system. If the resistance exceeds a safe limit it will indicate a fault.
Datasheet for Vigilon Loop Card
Similar Products:
Weight | 1 kg |
---|
Related products
-
Gent by Honeywell VESDA-E VEA(VER-A40-40-STX)
Read moreDESCRIPTION
The VESDA-E VEA series of detectors
combine VESDA reliability and early warning smoke detection with pinpoint addressability and a variety of annunciation options that truly surpass traditional spot detectors.COLOUR LCD DISPLAY
The VEA-040-A10 detector features a 3.5” colour LCD display which provides a range of status information including alarm and fault conditions as well as smoke level. Screens for each type of information are available using a simple navigation system.
VESDAnet™
VESDA detectors and devices communicate on VESDAnet which provides a
robust bi-directional communication network allowing continued redundant operation even during single point wiring failures. VESDAnet enables primary reporting, centralized configuration, control, maintenance and monitoring.
ETHERNET AND WIFI CONNECTIVITY
VESDA-E detectors offer Ethernet and WiFi connectivity as standard features. The detector can be added to a corporate network, allowing WiFi enabled tablet devices and laptops installed with Xtralis configuration software to connect
wirelessly to the detector via the network.
The VESDA-E VEA series of detectors
combine VESDA reliability and early warning smoke detection with pinpoint addressability and a variety of annunciation options that truly surpass traditional spot detectors -
Gent Conventional Optical Smoke Detector : Eco 1003
₦15,000.00₦13,500.00Add to cartPhoto-thermal model
Laser-based remote test unit
EN 54 Certified (2000 edition)
Photoelectric, photo-thermal and thermal detectors
Improved chamber design
Compatible with fire and security systems
-20 to +60ºC operating temperature range
Choice of bases (including a 12V relay version)
Photoelectric model with integral piezoelectric sounder
(availability subject to further announcement) -
Zeta Fyreye MkII Conventional Heat Detectors MKII-HF/CS90
₦9,500.00Add to cartDESCRIPTION
The Fyreye Rate of Rise heat detectors (MKII-HFCS90) use a thermistor arrangement to sense a quick rise in
temperature and also a final threshold temperature of 90°C. The Fyreye fixed heat detector (MKII-HF/CS90) has a single thermistor arrangement that gives an alarm at a temperature of 90°C.
There are 4 types of mounting base available; standard or deep and with or without diode. -
Zeta Fyreye MKII Diode Base
₦1,500.00Add to cartDESCRIPTION
Fyreye MKII Diode Base
Low profile or deep diode mounting base for the Fyreye MKII range of conventional detectors.
Popular Tags
Best offers
Join Risk Free
30 days refund
100% Safe
Secure Shopping
24x7 Support
Online 24 hours
Best Offers
Grab Now
Free Shiping
On all order over
Know Us
Safetech.hub is the newest online platform envisioned to provide 24/7 online platform for integrators, installers, and end users of Extra Low Voltage (ELV) systems in Nigeria
Read More
Reviews
There are no reviews yet.