Category
- Uncategorized
- Access Control and Time Attendance System
- Accessories
- Addressable base
- Audio
- Cable
- Call Point
- Cameras
- Closed Circuit Television System (CCTV)
- Computer & Laptop
- Door controller
- Fire Alarm System
- Home Appliances
- Manual Callpoints
- Metal Detector
- Naso mask
- New Arrival
- Night Vision
- On Sale
- Security Alarm System
Popular
-
C-Tec FP 8 Zone Conventional Fire Alarm Panel-Ff388-2
₦125,000.00₦120,000.00 -
SOCA SL-130 Dead Bolt Lock ( All purpose type )
₦15,000.00₦13,000.00 -
SOCA SL-100D Dead Bolt Lock ( for automatic door)
₦18,000.00₦15,000.00 - SOCA SL 100A Dead Bolt ₦15,000.00
- Soca SD-30 Armored Door Loop
Tag Clouds
C-TEC CFP Relay Output Card (Reset, Fault, Aux. & Remote & 8 Output Per Zone Relays) CFP763
- An optional system expansion device for use with CFP Standard 2-8 Zone Fire Panels or CFP AlarmSense 2-8 Zone Fire Panels.
- Provides four panel-controlled volt free relay outputs (reset, fault, aux. fire and remote) and eight output per zone relays.
- PCB mounts inside the CFP fire panel.
CFP Relay Output Card (Reset, Fault, Aux. & Remote & 8 Output Per Zone Relays)
CFP763
- An optional system expansion device for use with CFP Standard 2-8 Zone Fire Panels or CFP AlarmSense 2-8 Zone Fire Panels.
- Provides four panel-controlled volt free relay outputs (reset, fault, aux. fire and remote) and eight output per zone relays.
- PCB mounts inside the CFP fire panel.
- Reset relay is active during the panel’s reset cycle.
- Fault relay is active in any fault condition. This relay is failsafe and normally energised – if power is removed from the panel the relay will changeover to produce a fault signal.
- Aux. fire relay is active in an alarm condition provided all relevant delays have expired.
- Remote relay is active during any Alarm Condition provided all relevant delays have expired.
- Output per zone relays will changeover when the corresponding zone is in alarm (subject to certain conditions – for full details refer to the instructions, downloadable below).
- Outputs are NOT designed to switch mains voltages.
Dimensions | 8.2 × 12.5 cm |
---|
Related products
-
Gent Surface MCP (XENS-805) 470 Ohms Re-settable
₦12,000.00₦10,000.00Add to cartGent XENS-805 Surface MCP 470 Ohms Re-settable Gent Surface MCP (XENS-805) 470 Ohms Re-settable requires no hammer and is easy and safe to operate. Gent’s conventional manual call points are designed to provide a manual alarm interface to conventional fire alarm control panels. All call points are supplied in the standard red colour and are …
-
Gent Flush Manual Call Point (XENS-850) 470 Ohms Glass
Read moreGent XENS-850 Flush Manual Call Point 470 Ohms Glass
Gent Flush Manual Call Point are designed to provide a manual alarm interface to conventional fire alarm control panels. All call points are supplied in the standard red colour and are available in semi-flush mounting or surface mounting options. The manual call points are all with a 470 Ohm resistor and Normally Open contact, complete with glass.
Both break glass, and resettable operating elements can be used in the standard unit by a yellow strip on the element which becomes visible when activated.
With the addition of a hinged transparent cover the element may be protected against accidental operation.
A specialist test key may be inserted into the bottom of the unit to lower the glass and release the micro-switch and thus a full functional test is achieved.
-
Gent by Honeywell VESDA-E VEA(VER-A40-40-STX)
Read moreDESCRIPTION
The VESDA-E VEA series of detectors
combine VESDA reliability and early warning smoke detection with pinpoint addressability and a variety of annunciation options that truly surpass traditional spot detectors.COLOUR LCD DISPLAY
The VEA-040-A10 detector features a 3.5” colour LCD display which provides a range of status information including alarm and fault conditions as well as smoke level. Screens for each type of information are available using a simple navigation system.
VESDAnet™
VESDA detectors and devices communicate on VESDAnet which provides a
robust bi-directional communication network allowing continued redundant operation even during single point wiring failures. VESDAnet enables primary reporting, centralized configuration, control, maintenance and monitoring.
ETHERNET AND WIFI CONNECTIVITY
VESDA-E detectors offer Ethernet and WiFi connectivity as standard features. The detector can be added to a corporate network, allowing WiFi enabled tablet devices and laptops installed with Xtralis configuration software to connect
wirelessly to the detector via the network.
The VESDA-E VEA series of detectors
combine VESDA reliability and early warning smoke detection with pinpoint addressability and a variety of annunciation options that truly surpass traditional spot detectors -
Zeta Fyreye MkII Conventional Heat Detectors MKII-HF C/W Base
₦17,000.00₦15,000.00Add to cartDESCRIPTION
The Fyreye fixed heat detector (MKII-HF) has a
single thermistor arrangement that gives an alarm at a
temperature of 57°C.
There are 4 types of mounting base available; standard
or deep and with or without diode.
Popular Tags
Best offers
Join Risk Free
30 days refund
100% Safe
Secure Shopping
24x7 Support
Online 24 hours
Best Offers
Grab Now
Free Shiping
On all order over
Know Us
Safetech.hub is the newest online platform envisioned to provide 24/7 online platform for integrators, installers, and end users of Extra Low Voltage (ELV) systems in Nigeria
Read More
Reviews
There are no reviews yet.