Category
- Uncategorized
- Access Control and Time Attendance System
- Accessories
- Addressable base
- Audio
- Cable
- Call Point
- Cameras
- Closed Circuit Television System (CCTV)
- Computer & Laptop
- Door controller
- Fire Alarm System
- Home Appliances
- Manual Callpoints
- Metal Detector
- Naso mask
- New Arrival
- Night Vision
- On Sale
- Security Alarm System
Popular
-
C-Tec FP 8 Zone Conventional Fire Alarm Panel-Ff388-2
₦125,000.00₦120,000.00 -
SOCA SL-130 Dead Bolt Lock ( All purpose type )
₦15,000.00₦13,000.00 -
SOCA SL-100D Dead Bolt Lock ( for automatic door)
₦18,000.00₦15,000.00 - SOCA SL 100A Dead Bolt ₦15,000.00
- Soca SD-30 Armored Door Loop
Tag Clouds
APOLLO AlarmSense Relay Module Part No. 55000-835APO
- Allows devices such as vibrating pillow alarms or vibrating radio/paging devices to be connected to an AlarmSense system.
- Can also be used to monitor and switch conventional sounders and visual indicators.
- Allows devices such as vibrating pillow alarms or vibrating radio/paging devices to be connected to an AlarmSense system.
- Can also be used to monitor and switch conventional sounders and visual indicators.
- Suitable for use with C-TEC’s CFP AlarmSense range of 2-8 Zone Two-Wire Fire Panels.
- Operates in three configurations:-
- (1) relay activation places the AlarmSense Zone voltage across the output terminals.
- (2) relay activation reverses the polarity of the AlarmSense Zone voltage across the output terminals (to allow the use of monitored conventional sounders fitted with series diodes).
- (3) Two sets of volt-free contacts for use with door closure units, etc.
- Relay can be set to priority or non-priority by means of a DIL switch.
Protocol/compatibility | Suitable for use with C-TEC’s CFP AlarmSense range of 2-8 Zone Two-Wire Fire Panels. |
Supply/operating voltage | 9 to 33V DC. (Relay operation voltage less than 18V; Relay reset voltage less than 15V). |
Quiescent current | 20µA. |
Product dimensions (mm) | 65 W x 45 H x 25 D mm. |
IP Rating | TBC. |
Weight | 35g. |
Properties | Relay contact ratings 1A @ 30VDC. |
Operating conditions/temperature | -40ºC to +70ºC. |
Notes | Alarm relay resets on silence. |
Dimensions | 2.5 × 6.5 × 4.5 cm |
---|
Related products
-
APOLLO AlarmSense Base Sounder/Visual Indicator Part No. 45681-509APO
Read more- Will accept any AlarmSense fire detector to provide fire detection and an audible AND visual alarm warning signal at the same point.
- 70d-87dB(A) sound output (visual indicator activates with sounder).
- Certified to EN54-3 by UL International (UK) Limited.
- Suitable for use with C-TEC’s CFP AlarmSense range of 2-8 Zone Two-Wire Fire Panels.
- AlarmSense priority/non priority signal recognition
- Detects the removal of a detector head and reports a fault
- Continues to work during unauthorised removal of detector.
- High and low volume ranges.
- Red and white caps available for stand-alone use.
- Can also be purchased as part of a detector/sounder visual indicator base combination (see Combination AlarmSense Devices section below).
-
Gent 4 ZONE CONVENTIONAL PANEL, EN54 LESS BATTERIES (13270-04LB)
₦259,000.00₦235,500.00Add to cartDESCRIPTION
Gent 13270-04LB 4 Zone Conventional Xenex Fire Panel
BSI approved to EN54: Parts 2 & 4, the Xenex control panel can be used on installations meeting BS 5839:Part1. Control panel options for 2-8 zones can be specified.
Designed to simplify system installation, each Xenex panel contains an integral power supply and battery support to drive up to 8 alarm sounder circuits, 2 auxiliary relay contacts, a zone disablement facility and also one-man test and commissioning features.
-
Zeta Infinity 8 Conventional 1 Zone Fire Alarm Panel IN1
₦139,000.00₦127,000.00Add to cartDESCRIPTION
The Infinity 8 control panel is housed in the
most attractive, modern designed, flame
retardent ABS enclosure, utilising a switch
mode power supply. It has a fully removable
front cover which improves ease of access for
cable installations.
The Infinity 8 panel can also be ordered with a metal back
box facilitating upto 7ah batteries to fit within the panel
housing. To order this version add “/M” to the end of the
model number (i.e. IN1/M, IN2/M, etc.) -
C-TEC ActiV Conventional Hi-Output W-2.75-9 Wall VAD c/w 100dB(A) Sounder (shallow base) Part No. BF433C/CC/SR
Read more- Third-party certified to EN54-3 (Sounders) and EN54-23 (VADs).
- Provides ‘W-2.75-9’ rated light distribution when wall mounted (min. 0.4 lux over a 2.75 x 9m cuboid area). Also rated as a W-4-4 VAD.
- Impressive 100dB(A) sound output @ 1m.
- Includes 31 selectable primary tones and an optional secondary tone.
- Two volume levels (high and low)
- Three selectable VAD flash rates (0.5Hz, 1Hz, OFF)
- Alarm Current at 30Vdc = 12.2mA (0.5Hz) or 19.5mA (1Hz)
- Alarm Current at 18Vdc = 14.5mA (0.5Hz) or 25mA (1Hz)
- IP21C rated.
- Manufactured in the UK by C-TEC.
Popular Tags
Best offers
Join Risk Free
30 days refund
100% Safe
Secure Shopping
24x7 Support
Online 24 hours
Best Offers
Grab Now
Free Shiping
On all order over
Know Us
Safetech.hub is the newest online platform envisioned to provide 24/7 online platform for integrators, installers, and end users of Extra Low Voltage (ELV) systems in Nigeria
Read More
Reviews
There are no reviews yet.