Category
- Uncategorized
- Access Control and Time Attendance System
- Accessories
- Addressable base
- Audio
- Cable
- Call Point
- Cameras
- Closed Circuit Television System (CCTV)
- Computer & Laptop
- Door controller
- Fire Alarm System
- Home Appliances
- Manual Callpoints
- Metal Detector
- Naso mask
- New Arrival
- Night Vision
- On Sale
- Security Alarm System
Popular
-
C-Tec FP 8 Zone Conventional Fire Alarm Panel-Ff388-2
₦125,000.00₦120,000.00 -
SOCA SL-130 Dead Bolt Lock ( All purpose type )
₦15,000.00₦13,000.00 -
SOCA SL-100D Dead Bolt Lock ( for automatic door)
₦18,000.00₦15,000.00 - SOCA SL 100A Dead Bolt ₦15,000.00
- Soca SD-30 Armored Door Loop
Tag Clouds
C-TEC CFP Standard 4 Zone Conventional Fire Alarm Panel Part No. CFP704-4
₦73,000.00
- Third-party certified to EN54 parts 2 and 4 by the Loss Prevention Certification Board (LPCB)
- Intuitive user-friendly interface with colour-coded buttons and combined keypad/keyswitch entry
- Manufactured by C-TEC in the UK
- Eight detector zone circuits
- Four conventional sounder circuits
- Integral 1.5A EN54-4/A2 compliant switch mode PSU
- Wide range of test and fault-finding facilities
- Four open-collector outputs (Fire, Fault, Remote and Reset)
- ‘Class change’ and alert inputs
- Installer-friendly design
- Attractive flush or surface mountable plastic lid and enclosure – no bezel required
- Low 25mA quiescent current
- Multiple indicators
- No system expansion connections
- Fully compatible with C-TEC’s ActiV range of conventional fire detectors
LPCB certified to EN54-2/4, C-TEC’s CFP 8Â zone economy fire alarm panel offers an array of user and installer-friendly features at a very competitive price.
Supplied in an attractive flush or surface mountable plastic enclosure, it includes eight detector zones, four conventional sounder circuits, class change and alert inputs, four open collector outputs (fire, fault, reset and remote) and combined keypad/keyswitch entry.
Unlike our Standard CFP fire panel, the CFP708E-2 is NOT compatible with CFP repeaters, relay expansion boards or EN54-13 interface cards. It also has limited engineering functions.
-
-
Approvals/certifications Certified to EN54-2 & 4 by the LPCB. Mains supply 230V 50/60Hz. Mains rated current 350mA maximum. Internal power supply 19V-28.5V (27V nominal). Ripple 7V maximum (battery fault). Total output current limited to 1.5A @ 230Vac (ImaxA eq 146mA). Quiescent current 25mA (mains failed, internal sounder active, PSU & gen fault LED lit). Max battery size and type 2 x 12V 3.2Ah VRLA connected in series. Min. battery size 1.2Ah. No. of detector zone circuits 4 (Max. length per circuit is 500m). Call point resistor value 470 to 680Ω. Max. devices per detector zone 25 detectors (or 32 detectors/manual call points combined). No. of conventional sounder circuits 4 (Max. length per circuit is 500m). EOL resistor value 6800Ω 5% Tol. 0/25W (blue, grey, red, gold). Alarm voltage 27V max, 20V min (final battery voltage). Max. sounder output current 4 x 200mA (800mA total). Auxiliary relays Two: (1) Aux. Fire; (2) Fault. Volt free single pole changeover. Max. switch current 1A; Max. switch voltage 30Vdc. Open collector outputs Two: (1) Reset (Active during reset cycle); (2) Remote (Active during any unsilenced fire condition provided all relevant delays have expired). Max. sink current 30mA, Max. open circuit voltage 27Vdc). Other outputs 24V Aux. Power (Protected by a resettable fuse. 100mA min. hold current. Resets when fault removed). Auxiliary inputs Two: (1) ‘Class Change’ (constant sounders); (2) Alert (pulsed sounders). Connect to 0V to trigger, Max. input voltage 27V (non-latching). Engineer (AL3) functions Program coincidence (double knock); Invoke One Man Walk Test; Program delays; Set up zones for non-latching operation; Program sounders to resound (or not resound) when a new zone enters alarm; Enter fault diagnostic facilities. Expansion connections Yes – for optional network driver cards (one required per repeater system), relay output cards and EN54-13 sounder circuit interface boards. Product dimensions (mm) 380 W x 235 H x D 96mm. Construction & finish Plastic lid and base; RAL7035 textured. IP Rating IP30. Weight 1.75kg (without batteries). Operating conditions/temperature -5ºC to +40ºC. Max relative humidity: 95%
-
Weight | 1.75 kg |
---|---|
Dimensions | 380 × 235 × 96 cm |
Related products
-
APOLLO AlarmSense Base Sounder/Visual Indicator Part No. 45681-509APO
Read more- Will accept any AlarmSense fire detector to provide fire detection and an audible AND visual alarm warning signal at the same point.
- 70d-87dB(A) sound output (visual indicator activates with sounder).
- Certified to EN54-3Â by UL International (UK) Limited.
- Suitable for use with C-TEC’s CFP AlarmSense range of 2-8 Zone Two-Wire Fire Panels.
- AlarmSense priority/non priority signal recognition
- Detects the removal of a detector head and reports a fault
- Continues to work during unauthorised removal of detector.
- High and low volume ranges.
- Red and white caps available for stand-alone use.
- Can also be purchased as part of a detector/sounder visual indicator base combination (see Combination AlarmSense Devices section below).
-
C-TEC ActiV Conventional Hi-Output W-2.75-9 Wall VAD c/w 100dB(A) Sounder (shallow base) Part No. BF433C/CC/SR
Read more- Third-party certified to EN54-3 (Sounders) and EN54-23 (VADs).
- Provides ‘W-2.75-9’ rated light distribution when wall mounted (min. 0.4 lux over a 2.75Â x 9m cuboid area). Also rated as a W-4-4 VAD.
- Impressive 100dB(A) sound output @ 1m.
- Includes 31 selectable primary tones and an optional secondary tone.
- Two volume levels (high and low)
- Three selectable VAD flash rates (0.5Hz, 1Hz, OFF)
- Alarm Current at 30Vdc =Â 12.2mA (0.5Hz) or 19.5mA (1Hz)
- Alarm Current at 18Vdc =Â 14.5mA (0.5Hz) or 25mA (1Hz)
- IP21C rated.
- Manufactured in the UK by C-TEC.
-
HORING LIH AH-0621 UL Photoelectric Smoke Detector
Read more- UL Listed.
- The standard detector is 2-wire or 3-wire with base.
- For 4-wire type just add one relay output module on 3-wire base. Simple and easy module placement enables wider application.
- Twin-color LED display enables viewer to easily identify the current status of detector.
- Contacts material is highly acid-resistant and rust-resistant.
- Detector is made of high endurance, solid and colorfast Fire-proof plastic.
- Non-loosening screws on base terminal for easy installation.
- Detector has passed strict EMC test, which greatly eliminates false alarms caused by interference from nearby sources.
-
C-TEC ActiV Conventional Base Voice Sounder Part No. BF454C/CC/W
Read more-
-
- Superb sound intelligibility.
- Choose from two evacuation voice messages and four evacuation alarm tones (your selected evacuation message will be preceded by the selected tone).
- Alarm Current at 30Vdc = 10mA.
- Alarm Current at 18Vdc = 8mA.
- Optional BF330CTLIDW white or BF330CTLIDR red cap available for stand-alone use.
- Supplied with a BF431QCP quick connect plate and detector spur wires.
- IP21C rated.
-
-
Popular Tags
Best offers
Join Risk Free
30 days refund
100% Safe
Secure Shopping
24x7 Support
Online 24 hours
Best Offers
Grab Now
Free Shiping
On all order over
Know Us
Safetech.hub is the newest online platform envisioned to provide 24/7 online platform for integrators, installers, and end users of Extra Low Voltage (ELV) systems in Nigeria
Read More
Reviews
There are no reviews yet.