Category
- Uncategorized
- Access Control and Time Attendance System
- Accessories
- Addressable base
- Audio
- Cable
- Call Point
- Cameras
- Closed Circuit Television System (CCTV)
- Computer & Laptop
- Door controller
- Fire Alarm System
- Home Appliances
- Manual Callpoints
- Metal Detector
- Naso mask
- New Arrival
- Night Vision
- On Sale
- Security Alarm System
Popular
-
C-Tec FP 8 Zone Conventional Fire Alarm Panel-Ff388-2
₦125,000.00₦120,000.00 -
SOCA SL-130 Dead Bolt Lock ( All purpose type )
₦15,000.00₦13,000.00 -
SOCA SL-100D Dead Bolt Lock ( for automatic door)
₦18,000.00₦15,000.00 - SOCA SL 100A Dead Bolt ₦15,000.00
- Soca SD-30 Armored Door Loop
Tag Clouds
C-TEC FP 8 Zone Conventional Fire Alarm Panel (expandable to 14 zones) Part No. FF388-2
₦160,000.00
-
-
-
- DESCRIPTION
- Installer-friendly design
- Robust metal enclosure c/w lift off lid & heavy-duty base connections.
- 12 conventional Zone circuits (expandable to 14).
- Two conventional Sounder circuits.
- Separate indicators for open &Â short circuit fault, sounder fault and battery/power supply fault.
- Non-latching class change sounder output, latching fire &Â non-latching fault outputs (via expansion loom).
- Short circuit=fire facility (pre-1980 BS, no resistors in call points, selectable on a zone by zone basis).
- Ancillary connections for repeaters & other system add-ons including fault relay modules, fire relay modules, sounder delay relay modules, sounder extender kits, etc).
- Multi-lingual variants (subject to quantities).
- Space for 2Â x 12V 7Ah VRLA batteries.
- Compatible with virtually all known conventional fire detectors including C-TEC’s ActiV range.
- Designed to comply with BS 5839-4 (this panel in not compliant with EN54-2/4 and should NOT be used in new UK or European installations).
-
-
- Overview
Installer-friendly design.
Robust metal enclosure c/w lift off lid & heavy-duty base connections.
Eight conventional Zone circuits (expandable to 14).
Two conventional Sounder circuits.
Separate indicators for open &short circuit fault, sounder fault and battery/power supply fault.
Non-latching class change sounder output, latching fire &non-latching fault outputs (via expansion loom).
Short circuit=fire facility (pre-1980 BS, no resistors in call points, selectable on a zone by zone basis).
Ancillary connections for repeaters &other system add-ons including fault relay modules, fire relay modules, sounder delay relay modules, sounder
extender kits, etc).
Multi-lingual variants (subject to quantities).
Space for 2x 12V 7Ah VRLA batteries.
Compatible with virtually all known conventional fire detectors including C-TEC’s ActiV range.
Designed to comply with BS 5839-4 (this panel in not compliant with EN54-2/4 and should NOT be used in new UK or European installations). - TECHNICAL SPECIFICATION
-
Compatibility Designed to comply with the requirements of BS5839-4 (for head-out monitoring use 1 x BF378M module per zone). Mains supply 230V 50/60Hz. Mains rated current 330mA max. Internal power supply 27V nominal. Total output current limited to 1400mA @ 230V. Quiescent current 70mA (with no mains supply, fault beeper muted, no aux. output connections, EOL devices and resistors only fitted to detector and sounder loops). Max battery size and type 2 x 12V 3.2Ah VRLA connected in series. No. of detector zone circuits 8 (Max. length per circuit is 500m). Additional Zones cannot be added to this panel. For head out monitoring 1 x BF378M is required per Zone. Call point resistor value 470 to 680Ω. Max. devices per detector zone 20 detectors (max. detector current 2mA). No limit for manual call points. No. of conventional sounder circuits 2 (Max. length per circuit is 500m). EOL resistor value 6800Ω 5% Tol. 0/25W (blue, grey, red, gold). Max. sounder output current 1400mA (to all outputs). Outputs are fused at 1A. Auxiliary relays 1 x onboard relay (1A, 30 VDC, follows sounders). Additional relays available via optional expansion looms (FF374FR, FF374FDR & FF374DT). Open collector outputs Available via optional expansion loom FF374X. Auxiliary inputs Available via optional expansion loom FF374X. Indicators Mains on; Zone Fire; Zone Fault; Sounder Fault; Battery/Power Supply Fault; O/C fault; S/C fault; Zone isolated; Engineer Test selected. Controls Reset; Resound; Test Zone Lamps; Evacuate; Silence Alarm Sounders; Silence Fault Sounders; Revert to S/C equals Fire; OMT, Zone Isolate. Keyswitch. Product dimensions (mm) 405 W x 267 H x D 92mm. Construction & finish Metal lid and base. IP Rating IP30. Weight 5.0kg. Operating conditions/temperature -5ºC to +40ºC. Max relative humidity: 95%. Notes - Repeater info: Up to 3 repeaters per main. 5 cores plus 1 per zone. Max. cable length 200m.
Weight | 9.2 kg |
---|---|
Dimensions | 140 × 521 × 334 cm |
Related products
-
Gent Conventional Optical Smoke Detector : Eco 1003
₦15,000.00₦13,500.00Add to cartPhoto-thermal model
Laser-based remote test unit
EN 54 Certified (2000 edition)
Photoelectric, photo-thermal and thermal detectors
Improved chamber design
Compatible with fire and security systems
-20 to +60ºC operating temperature range
Choice of bases (including a 12V relay version)
Photoelectric model with integral piezoelectric sounder
(availability subject to further announcement) -
Gent Single Mode Fibre Network Card (VIG-NC-SMF)
₦440,000.00Add to cartThe Single Mode Fibre Network Card (VIG-NC-SMF) allows a fast and reliable network over distances of up to 20km between Vigilon Plus Panels (VIGPLUS-24, VIGPLUS-72) / Network Nodes (VIGPLUS-NODE).
The Single Mode Fibre Network card is designed to plug into the backplane of a panel or node in dedicated slots.
Fibre optic connects directly to the sockets on the card.
Up to 31 panels/nodes on a single network.
Up to 200 panels/nodes on a complex networks. -
Gent Vigilon VIG-IOC-DOM Input/Output Domain Card
₦1,315,000.00Add to cartGent Vigilon Input / Output Domain Card – VIG-IOC-DOM
The VIG-IOC-DOM is a Vigilon EN54 Input Output Domain Card for Vigilon Control Panels.
Key Features
- EN54
-
Zeta ID2/8/M Infinity ID2 Intelligent 2 Wire 8 Zone Fire Panel in Metal Enclosure
Read moreDESCRIPTION
Zeta Alarm Systems is proud to introduce the most advanced 2 wire system on the market. We can now provide a system that gives all of the benefits associated with a ‘2 Wire’ installation (less cable, quicker installation, cost savings on labour/product) and has the facility to ‘I.D.’ the devices.
The system is built on the proven communication protocol developed by Zeta Alarm Systems and shares the same platform as our largest, most powerful system.
The ID2 can be used for new installations, as a retrofit for any conventional system or as a replacement for existing 2 wire systems when the extra features are deemed to be desirable/necessary. This is possible because the ID2 devices sit on radial circuits, thus making it easy to ‘upgrade’ a system with the facility to I.D. devices without the need to re-wire.
Popular Tags
Best offers
Join Risk Free
30 days refund
100% Safe
Secure Shopping
24x7 Support
Online 24 hours
Best Offers
Grab Now
Free Shiping
On all order over
Know Us
Safetech.hub is the newest online platform envisioned to provide 24/7 online platform for integrators, installers, and end users of Extra Low Voltage (ELV) systems in Nigeria
Read More
Reviews
There are no reviews yet.