C-TEC 24V 1.5A Encased Switch Mode PSU to EN54-4/A2 Part No. BF560-24/E
- A powerful switch mode/digital hybrid PSU that can be customised to suit your exact requirements – see More Information tab for details.
- Plastic cover on PSU PCB guards against touching live parts (to VDE 0100-410).
- Includes the same electronics as our BF560-24 LPCB certified EN54-4/A2 boxed 24V 1.5A PSU.
- Metal base plate facilitates straightforward mounting inside third-party OEM enclosures.
- Includes a single-pole volt-free changeover relay that switches for any fault condition.
- Includes a fault type & hazardous voltages present LED.
- Two selectable battery charge currents.
- Battery fault impedance limits can be optimised to suit load current (helps extend battery life)*.
- Mains fail simulation mode.
- Improved on-board temperature sensor with optional remote sensor.
- Electronic functions comply with EN50131-6 grades 1-4 for security applications.
PSU CUSTOMISATION
The BF560-24/E can be optionally customised to suit your exact requirements using a BF423 configurator and PC. Configurable parameters include Float voltage temperature compensation; Battery charge rate (mA); Battery impedance; Configurable Input/Output settings.
PSU STATUS LED (located on the PSU PCB)
1 flash = Mains Failure.
2 flashes = Battery Voltage Low.
3 flashes = Battery Voltage Critical.
4 flashes = Charger Failure.
5 flashes = Charger OK (Battery is either actively charging, or in float charge).
6 flashes = No Batteries Fitted (indicating DIP Switch 4 position).
7 flashes = Battery Resistance Fault (Level set by DIP Switch 2 position).
8 flashes = Output Over Voltage.
BATTERY FAULT MONITORING
The BF560-24/E monitors battery resistance to the requirements of EN54-4/A2. The fault threshold is directly related to the ability of the battery to deliver the rated current to the load. For example, batteries stored uncharged for long periods, during shipment and/or distribution, degrade leading to increased internal resistance. If a degraded battery is fitted, a fault will be shown by the PSU as mandated by EN54-4/A2.
DATA PORT
Data on the BF560-24/E’s status can be extracted from the PSU’s bi-directional data port. The data available includes thermistor measurements; battery terminal voltage; system voltage at load terminals; battery charge current; load current; battery impedance and ASCII text string status messages. Extracting this data requires additional equipment and permissions – contact C-TEC for details.
Related products
-
Solo 823 Smoke & Cordless Heat Detector Test Set 9.3 Metres
₦2,500,000.00₦2,261,000.00Add to cartSolo 823 Smoke & Cordless Heat Detector Test Set 9.3 metres Solo equipment is available in a number of conveniently arranged kits. Whether your need is for a simple starter kit, a universal smoke testing kit, or an all encompassing kit including a heat detector tester, there is one available. Larger kits are supplied with …
Solo 823 Smoke & Cordless Heat Detector Test Set 9.3 MetresRead More
-
Gent by Honeywell VESDA-E VEA-40 Aspirating Smoke Detector with LED Displays(VEA-040-A00)
Read morecombine VESDA reliability and early warning smoke detection with pinpoint addressability and a variety of annunciation options that truly surpass traditional spot detectors.
They use patented air sampling points and multichannel microbore air-sampling with three alarm sensitivity settings for the sampling points. As a
multi-channel, addressable system, the VEA detector is able to divide a
protected space into sampling locations, enabling the localization of potential sources of fire for faster incident response. The detectors are suitable for
protection of areas where pinpoint location of fire events is essential, thus providing ideal fire detection solutions for healthcare, offices, education, retail, prisons and electrical cabinets. A wide range of features provide flexibility, field programmability, enhanced connectivity and reduced total cost of ownership. -
Zeta Fyreye MKII Diode Base
₦1,500.00Add to cartDESCRIPTION
Fyreye MKII Diode Base
Low profile or deep diode mounting base for the Fyreye MKII range of conventional detectors.
-
APOLLO GREEN INTELLIGENT MANUAL CALL POINT (SA5900-906APO)
Read moreThe Manual Call Point is commonly used to manually release secure doors or barriers in the event of emergency.
- Resettable operating element
- 170° viewable LED
- Suitable for semi flush or surface mounting
- ‘Plug and Play’ terminal connections for faster wiring
- Continuity link for wiring test before commissioning
- XP95, Discovery and CoreProtocol compatible
Popular Tags
Best offers
Join Risk Free
30 days refund
100% Safe
Secure Shopping
24x7 Support
Online 24 hours
Best Offers
Grab Now
Free Shiping
On all order over
Know Us
Safetech.hub is the newest online platform envisioned to provide 24/7 online platform for integrators, installers, and end users of Extra Low Voltage (ELV) systems in Nigeria
Read More
Reviews
There are no reviews yet.