Category
- Uncategorized
- Access Control and Time Attendance System
- Accessories
- Addressable base
- Audio
- Cable
- Call Point
- Cameras
- Closed Circuit Television System (CCTV)
- Computer & Laptop
- Door controller
- Fire Alarm System
- Home Appliances
- Manual Callpoints
- Metal Detector
- Naso mask
- New Arrival
- Night Vision
- On Sale
- Security Alarm System
Popular
-
C-Tec FP 8 Zone Conventional Fire Alarm Panel-Ff388-2
₦125,000.00₦120,000.00 -
SOCA SL-130 Dead Bolt Lock ( All purpose type )
₦15,000.00₦13,000.00 -
SOCA SL-100D Dead Bolt Lock ( for automatic door)
₦18,000.00₦15,000.00 - SOCA SL 100A Dead Bolt ₦15,000.00
- Soca SD-30 Armored Door Loop
Tag Clouds
AlarmSense Integrating Optical Smoke Detector
 55000-391APO
- An integrating optical smoke detector.
- Responds well to slow-burning, smouldering fires.
- Suitable for use with C-TEC’s CFP AlarmSense range of 2-8 Zone Two-Wire Fire Panels.
- Housed in a pure white polycarbonate moulding.
- Fitted with two alarm LEDs to allow 360º visibility.
- Third-party certified to EN54-7 by UL International (UK) Limited.
- 9-33V DC operating voltage.
- Requires a 45681-244APO AlarmSense base.
- Can also be purchased as part of a detector/sounder or detector/sounder visual indicator base combination (see Combination AlarmSense Devices section below).
Approvals/certifications | Certified to EN54-7 by UL International (UK) Limited. |
Application/operation | Generates an alarm condition when it detects a pre-set threshold of smoke penetration into the smoke chamber. |
Supply wiring | 2-wire monitored, polarity insensitive. |
Supply/operating voltage | 9 to 33V DC. |
Quiescent current | 50µA @ 15 VDC. |
Alarm voltage | 9-33V DC. |
Alarm current | 1.5mA @ 2-8.5V; 25 +/- 2mA @ 10.5-15V; 1.5AmA @ 18-24V; 2mA @ 33V. |
Alarm reset voltage | 2V max (1 second alarm reset time). |
Product dimensions (mm) | 100mm diameter x 42m deep (detector only); 100mm diameter x 50mm deep (detector in base). |
Construction & finish | White polycarbonate. |
IP Rating | TBC. |
Weight | 100g. |
Related products
-
HORING LIH AH-0621 UL Photoelectric Smoke Detector
Read more- UL Listed.
- The standard detector is 2-wire or 3-wire with base.
- For 4-wire type just add one relay output module on 3-wire base. Simple and easy module placement enables wider application.
- Twin-color LED display enables viewer to easily identify the current status of detector.
- Contacts material is highly acid-resistant and rust-resistant.
- Detector is made of high endurance, solid and colorfast Fire-proof plastic.
- Non-loosening screws on base terminal for easy installation.
- Detector has passed strict EMC test, which greatly eliminates false alarms caused by interference from nearby sources.
-
APOLLO DISCOVERY MANUAL CALL POINT – OUTDOOR – YELLOW – ISOLATING 58100-953APO
Read moreThe Manual Call Point is used to control extinguishant release rather than to initiate an alarm signal on the fire detection system.
- Suitable for weatherproof applications
- Reports an alarm in under 0.2 seconds
- ‘Plug and Play’ terminal connections for faster wiring
- Continuity link for wiring test before commissioning
- XP95 & Discovery compatible
-
Zeta ID2/8/M Infinity ID2 Intelligent 2 Wire 8 Zone Fire Panel in Metal Enclosure
Read moreDESCRIPTION
Zeta Alarm Systems is proud to introduce the most advanced 2 wire system on the market. We can now provide a system that gives all of the benefits associated with a ‘2 Wire’ installation (less cable, quicker installation, cost savings on labour/product) and has the facility to ‘I.D.’ the devices.
The system is built on the proven communication protocol developed by Zeta Alarm Systems and shares the same platform as our largest, most powerful system.
The ID2 can be used for new installations, as a retrofit for any conventional system or as a replacement for existing 2 wire systems when the extra features are deemed to be desirable/necessary. This is possible because the ID2 devices sit on radial circuits, thus making it easy to ‘upgrade’ a system with the facility to I.D. devices without the need to re-wire.
-
Zeta Fyreye MkII Conventional Heat Detectors MKII-HF/CS90
₦9,500.00Add to cartDESCRIPTION
The Fyreye Rate of Rise heat detectors (MKII-HFCS90) use a thermistor arrangement to sense a quick rise in
temperature and also a final threshold temperature of 90°C. The Fyreye fixed heat detector (MKII-HF/CS90) has a single thermistor arrangement that gives an alarm at a temperature of 90°C.
There are 4 types of mounting base available; standard or deep and with or without diode.
Popular Tags
Best offers
Join Risk Free
30 days refund
100% Safe
Secure Shopping
24x7 Support
Online 24 hours
Best Offers
Grab Now
Free Shiping
On all order over
Know Us
Safetech.hub is the newest online platform envisioned to provide 24/7 online platform for integrators, installers, and end users of Extra Low Voltage (ELV) systems in Nigeria
Read More
Reviews
There are no reviews yet.