Category
- Burglary Alarm System
- Cable
- Closed Circuit Television System (CCTV)
- Fire Equipment
- Pepper Spray Vault/ATM Protection System
- Personal Security
- Physical Access Control
Popular
- Gent Fire Alarm System Set of Keys for Key Switch Interface and MCP
- Gent Fire Alarm Vigilon Manual Call Point with Glass Element and Protective Cover (Excludes Back Box)
- Cutting-Edge Velocity Zeta Aspiration Smoke Detection Fire Alarm Panel
-
GENT ADDRESSABLE FIRE ALARM 1 TO 6 LOOP CONTROL PANEL
₦6,250,000.00₦6,170,000.00 -
TEXECOM VERITAS IMPAQ E BURGLAR ALARM VIBRATION DETECTOR- WHITE
₦22,000.00₦18,500.00 -
PAXTON ACCESS CONTROL NET2 PLUS 1 DOOR CONTROLLER – POE+, PLASTIC CABINET
₦462,000.00₦458,000.00 -
Concept Handheld Metal Detector with Vibration Function
₦20,000.00₦19,000.00 -
Fisher Research Labs M-scope Walk-Through Metal Detector
₦4,600,000.00₦4,500,000.00 -
CONCEPT (Burglar Alarm) WIRELESS SIGNAL REPEATER
₦23,500.00₦21,500.00 -
CONCEPT (Fire Alarm) TUYA WIFI SMOKE DETECTOR
₦13,000.00₦11,000.00
AlarmSense Standard Rate of Rise Heat Detector
55000-190APO
- A high quality Type A1R rate of rise heat detector.
- Suitable for use with C-TEC’s CFP AlarmSenSe range of 2-8 Zone Two-Wire Fire Panels.
- Housed in a pure white polycarbonate moulding.
- Fitted with two alarm LEDs to allow 360º visibility.
- Third-party certified to EN54-5 by UL International (UK) Limited.
- 9-33V DC operating voltage.
- Requires a 45681-244APO AlarmSense base.
- Can also be purchased as part of a detector/sounder or detector/sounder visual indicator base combination (see Combination AlarmSense Devices section below).
Approvals/certifications | Certified to EN54-5 by UL International (UK) Limited. |
Application/operation | Generates an alarm condition when it detects a temperature of between 84ºC & 100ºC. |
Application temperature | 55°C typical, 80°C max. |
Static response temperature | 84°C min, 100°C max. |
Supply wiring | 2-wire monitored, polarity insensitive. |
Supply/operating voltage | 9 to 33V DC. |
Quiescent current | 50µA @ 15 VDC. |
Alarm voltage | 9-33V DC. |
Alarm current | 1.5mA @ 2-8.5V; 25 +/- 2mA @ 10.5-15V; 1.5AmA @ 18-24V; 2mA @ 33V. |
Alarm reset voltage | 2V max (1 second alarm reset time). |
Product dimensions (mm) | 100mm diameter x 42m deep (detector only); 100mm diameter x 50mm deep (detector in base). |
Construction & finish | White polycarbonate. |
IP Rating | TBC. |
Weight | 100g. |
Detector
55000-391APO
- An integrating optical smoke detector.
- Responds well to slow-burning, smouldering fires.
- Suitable for use with C-TEC’s CFP AlarmSense range of 2-8 Zone Two-Wire Fire Panels.
- Housed in a pure white polycarbonate moulding.
- Fitted with two alarm LEDs to allow 360º visibility.
- Third-party certified to EN54-7 by UL International (UK) Limited.
- 9-33V DC operating voltage.
- Requires a 45681-244APO AlarmSense base.
- Can also be purchased as part of a detector/sounder or detector/sounder visual indicator base combination (see Combination AlarmSense Devices section below).
Approvals/certifications | Certified to EN54-7 by UL International (UK) Limited. |
Application/operation | Generates an alarm condition when it detects a pre-set threshold of smoke penetration into the smoke chamber. |
Supply wiring | 2-wire monitored, polarity insensitive. |
Supply/operating voltage | 9 to 33V DC. |
Quiescent current | 50µA @ 15 VDC. |
Alarm voltage | 9-33V DC. |
Alarm current | 1.5mA @ 2-8.5V; 25 +/- 2mA @ 10.5-15V; 1.5AmA @ 18-24V; 2mA @ 33V. |
Alarm reset voltage | 2V max (1 second alarm reset time). |
Product dimensions (mm) | 100mm diameter x 42m deep (detector only); 100mm diameter x 50mm deep (detector in base). |
Construction & finish | White polycarbonate. |
IP Rating | TBC. |
Weight | 100g. |
Related products
-
FISHER WALKTHROUGH METAL DETECTOR Protective Cover
₦50,000.00₦45,000.00Add to cartProtective Cover A durable protective cover for transportation or storage.
-
Concept (Burglar Alarm) Wired PIR detector
₦5,500.00Add to cartDescription Specifications Detection angle 90° Detection Distance 10m Working voltage DC 9-16V Working current 18mA Alarm output NO/NC optional Environment Humidity ≤95%RH(No congelation) Operating temperature -10℃~ +50℃ Anti RFI & EMI 10MHz-1GHz 20V/m Anti-white light 100000Lux . Case Material ABS plastic . Sensitivity & pluse count adjustable
-
GENT Analogue Addressable Fire Alarm Manual Call Points C/W COVER ELEMENT -S4-34845
₦55,000.00₦49,500.00Add to cartDescription
Manual call points for the Vigilon and Nano system are easy to install and can be mounted on standard installation back boxes or bespoke red back boxes for surface mounting. -
Out of Stock
Gent Fire Alarm Beam Sensors Pair (Transmitter & Receiver) Excluding Bracket and BaseS4-34740
Read moreGent S4-34740 Addressable Beam Sensor Pair
Gent S4-34740 S-Quad Addressable Loop Powered Beam Sensors Pair provides an enhanced solution for linear beam detection for applications where point detection is either not practical or economic.
Best offers
Join Risk Free
30 days refund
100% Safe
Secure Shopping
24x7 Support
Online 24 hours
Best Offers
Grab Now
Safe and Secured Payment
On all order over
Know Us
Safetech.hub is the newest online platform envisioned to provide 24/7 online platform for integrators, installers, and end users of Extra Low Voltage (ELV) systems in Nigeria
Read More
Reviews
There are no reviews yet.