Category
- Uncategorized
- Access Control and Time Attendance System
- Accessories
- Addressable base
- Audio
- Cable
- Call Point
- Cameras
- Closed Circuit Television System (CCTV)
- Computer & Laptop
- Door controller
- Fire Alarm System
- Home Appliances
- Manual Callpoints
- Metal Detector
- Naso mask
- New Arrival
- Night Vision
- On Sale
- Security Alarm System
Popular
-
C-Tec FP 8 Zone Conventional Fire Alarm Panel-Ff388-2
₦125,000.00₦120,000.00 -
SOCA SL-130 Dead Bolt Lock ( All purpose type )
₦15,000.00₦13,000.00 -
SOCA SL-100D Dead Bolt Lock ( for automatic door)
₦18,000.00₦15,000.00 - SOCA SL 100A Dead Bolt ₦15,000.00
- Soca SD-30 Armored Door Loop
Tag Clouds
C-TEC FP 8 Zone Conventional Fire Alarm Panel (expandable to 14 zones) Part No. FF388-2
₦160,000.00
-
-
-
- DESCRIPTION
- Installer-friendly design
- Robust metal enclosure c/w lift off lid & heavy-duty base connections.
- 12 conventional Zone circuits (expandable to 14).
- Two conventional Sounder circuits.
- Separate indicators for open &Â short circuit fault, sounder fault and battery/power supply fault.
- Non-latching class change sounder output, latching fire &Â non-latching fault outputs (via expansion loom).
- Short circuit=fire facility (pre-1980 BS, no resistors in call points, selectable on a zone by zone basis).
- Ancillary connections for repeaters & other system add-ons including fault relay modules, fire relay modules, sounder delay relay modules, sounder extender kits, etc).
- Multi-lingual variants (subject to quantities).
- Space for 2Â x 12V 7Ah VRLA batteries.
- Compatible with virtually all known conventional fire detectors including C-TEC’s ActiV range.
- Designed to comply with BS 5839-4 (this panel in not compliant with EN54-2/4 and should NOT be used in new UK or European installations).
-
-
- Overview
Installer-friendly design.
Robust metal enclosure c/w lift off lid & heavy-duty base connections.
Eight conventional Zone circuits (expandable to 14).
Two conventional Sounder circuits.
Separate indicators for open &short circuit fault, sounder fault and battery/power supply fault.
Non-latching class change sounder output, latching fire &non-latching fault outputs (via expansion loom).
Short circuit=fire facility (pre-1980 BS, no resistors in call points, selectable on a zone by zone basis).
Ancillary connections for repeaters &other system add-ons including fault relay modules, fire relay modules, sounder delay relay modules, sounder
extender kits, etc).
Multi-lingual variants (subject to quantities).
Space for 2x 12V 7Ah VRLA batteries.
Compatible with virtually all known conventional fire detectors including C-TEC’s ActiV range.
Designed to comply with BS 5839-4 (this panel in not compliant with EN54-2/4 and should NOT be used in new UK or European installations). - TECHNICAL SPECIFICATION
-
Compatibility Designed to comply with the requirements of BS5839-4 (for head-out monitoring use 1 x BF378M module per zone). Mains supply 230V 50/60Hz. Mains rated current 330mA max. Internal power supply 27V nominal. Total output current limited to 1400mA @ 230V. Quiescent current 70mA (with no mains supply, fault beeper muted, no aux. output connections, EOL devices and resistors only fitted to detector and sounder loops). Max battery size and type 2 x 12V 3.2Ah VRLA connected in series. No. of detector zone circuits 8 (Max. length per circuit is 500m). Additional Zones cannot be added to this panel. For head out monitoring 1 x BF378M is required per Zone. Call point resistor value 470 to 680Ω. Max. devices per detector zone 20 detectors (max. detector current 2mA). No limit for manual call points. No. of conventional sounder circuits 2 (Max. length per circuit is 500m). EOL resistor value 6800Ω 5% Tol. 0/25W (blue, grey, red, gold). Max. sounder output current 1400mA (to all outputs). Outputs are fused at 1A. Auxiliary relays 1 x onboard relay (1A, 30 VDC, follows sounders). Additional relays available via optional expansion looms (FF374FR, FF374FDR & FF374DT). Open collector outputs Available via optional expansion loom FF374X. Auxiliary inputs Available via optional expansion loom FF374X. Indicators Mains on; Zone Fire; Zone Fault; Sounder Fault; Battery/Power Supply Fault; O/C fault; S/C fault; Zone isolated; Engineer Test selected. Controls Reset; Resound; Test Zone Lamps; Evacuate; Silence Alarm Sounders; Silence Fault Sounders; Revert to S/C equals Fire; OMT, Zone Isolate. Keyswitch. Product dimensions (mm) 405 W x 267 H x D 92mm. Construction & finish Metal lid and base. IP Rating IP30. Weight 5.0kg. Operating conditions/temperature -5ºC to +40ºC. Max relative humidity: 95%. Notes - Repeater info: Up to 3 repeaters per main. 5 cores plus 1 per zone. Max. cable length 200m.
Weight | 9.2 kg |
---|---|
Dimensions | 140 × 521 × 334 cm |
Related products
-
Gent by Honeywell VESDA-E VEA-40 Aspirating Smoke Detector with LED Displays(VEA-040-A00)
Read morecombine VESDA reliability and early warning smoke detection with pinpoint addressability and a variety of annunciation options that truly surpass traditional spot detectors.
They use patented air sampling points and multichannel microbore air-sampling with three alarm sensitivity settings for the sampling points. As a
multi-channel, addressable system, the VEA detector is able to divide a
protected space into sampling locations, enabling the localization of potential sources of fire for faster incident response. The detectors are suitable for
protection of areas where pinpoint location of fire events is essential, thus providing ideal fire detection solutions for healthcare, offices, education, retail, prisons and electrical cabinets. A wide range of features provide flexibility, field programmability, enhanced connectivity and reduced total cost of ownership. -
Gent Flush Manual Call Point (XENS-850) 470 Ohms Glass
Read moreGent XENS-850 Flush Manual Call Point 470 Ohms Glass
Gent Flush Manual Call Point are designed to provide a manual alarm interface to conventional fire alarm control panels. All call points are supplied in the standard red colour and are available in semi-flush mounting or surface mounting options. The manual call points are all with a 470 Ohm resistor and Normally Open contact, complete with glass.
Both break glass, and resettable operating elements can be used in the standard unit by a yellow strip on the element which becomes visible when activated.
With the addition of a hinged transparent cover the element may be protected against accidental operation.
A specialist test key may be inserted into the bottom of the unit to lower the glass and release the micro-switch and thus a full functional test is achieved.
-
APOLLO GREEN INTELLIGENT MANUAL CALL POINT (SA5900-906APO)
Read moreThe Manual Call Point is commonly used to manually release secure doors or barriers in the event of emergency.
- Resettable operating element
- 170° viewable LED
- Suitable for semi flush or surface mounting
- ‘Plug and Play’ terminal connections for faster wiring
- Continuity link for wiring test before commissioning
- XP95, Discovery and CoreProtocol compatible
-
APOLLO ISOLATOR – NEGATIVE 55000-720APO
Read moreThe Isolator is placed at intervals on the loop and ensures that, in the case of a short circuit, only the section between the isolators will be affected. When the short-circuit is removed, the isolators automatically restore power and data to the isolated section
- Detects wiring short-circuits
- Minimises disruption from short-circuits
- Automatic de-isolation on the short-circuit removal
Popular Tags
Best offers
Join Risk Free
30 days refund
100% Safe
Secure Shopping
24x7 Support
Online 24 hours
Best Offers
Grab Now
Free Shiping
On all order over
Know Us
Safetech.hub is the newest online platform envisioned to provide 24/7 online platform for integrators, installers, and end users of Extra Low Voltage (ELV) systems in Nigeria
Read More
Reviews
There are no reviews yet.