Category
- Burglary Alarm System
- Cable
- Closed Circuit Television System (CCTV)
- Fire Equipment
- Pepper Spray Vault/ATM Protection System
- Personal Security
- Physical Access Control
- Promotions
Popular
- Gent Fire Alarm System Set of Keys for Key Switch Interface and MCP
- Gent Fire Alarm Vigilon Manual Call Point with Glass Element and Protective Cover (Excludes Back Box)
- Cutting-Edge Velocity Zeta Aspiration Smoke Detection Fire Alarm Panel
-
GENT ADDRESSABLE FIRE ALARM 1 TO 6 LOOP CONTROL PANEL
₦6,250,000.00Original price was: ₦6,250,000.00.₦6,170,000.00Current price is: ₦6,170,000.00. -
TEXECOM VERITAS IMPAQ E BURGLAR ALARM VIBRATION DETECTOR- WHITE
₦22,000.00Original price was: ₦22,000.00.₦18,500.00Current price is: ₦18,500.00. -
PAXTON ACCESS CONTROL NET2 PLUS 1 DOOR CONTROLLER – POE+, PLASTIC CABINET
₦462,000.00Original price was: ₦462,000.00.₦458,000.00Current price is: ₦458,000.00. -
Concept Handheld Metal Detector with Vibration Function
₦20,000.00Original price was: ₦20,000.00.₦19,000.00Current price is: ₦19,000.00. -
Fisher Research Labs M-scope Walk-Through Metal Detector
₦4,600,000.00Original price was: ₦4,600,000.00.₦4,500,000.00Current price is: ₦4,500,000.00. -
CONCEPT (Burglar Alarm) WIRELESS SIGNAL REPEATER
₦23,500.00Original price was: ₦23,500.00.₦21,500.00Current price is: ₦21,500.00. -
CONCEPT (Fire Alarm) TUYA WIFI SMOKE DETECTOR
₦13,000.00Original price was: ₦13,000.00.₦11,000.00Current price is: ₦11,000.00.
Gent Fire Alarm Surface Mount Base with Dual Diodes 17801-01
- Key Features
- Common to all Gent series detectors
- Automatic locking option
- Head out continuity monitoring
- Easy to install
The Gent 17801-01 is a Polar White conventional fire detector base with diode. It allows any Gent 17801-01 conventional detector to be removed or replaced without disconnecting wiring from detector terminals. Detectors plug into the base units with a simple twist and lock action, allowing quick and easy removal for cleaning and servicing, or reselection of detector type should the usage of the protected area change.
Designed for systems complying with the recommendations of Gent 17801-01 where the removal of a detector from its base must not affect the operation of devices wired further down the line, the Gent 17801-01 base includes a diode arrangement providing line continuity. When using the Gent 17801-01 with any conventional control panel for head out monitoring, the line must be terminated with a active end-of-line device.
Robust wiring terminals
Forming an integral part of the overall detector assembly, the base is provided with slots for screw fixing to either surface wiring plates, or conduit boxes with screw fixing centres between 50 and 90 mm.
The Gent 17801-01 features robust wiring terminals with captive clamping washers to ensure secure wiring termination. The bases are of shallow design with ample space to accommodate cables of all types. Terminals are provided inside the moulding for the connection of a remote LED when required.
Automatic locking
In order to prevent the unauthorised removal of a detector from its base, an automatic locking breakout is incorporated into all detector mouldings. When this breakout is removed, detectors can then only be released from their bases by the use of a special tool. The locking facility is an easily applied option often taken on-site at the system commissioning stage.
For systems where head out continuity is not a requirement, the Gent 17801-01 base should be installed.
Related products
-
Out of Stock
Apollo Addressable Fire Alarm E-Z Fit Base – 6″ Ultra-Low Profile Detector Mount
Read more- Four-wire base
- Detector locking mechanism
- One way fit
- Easy to wire
- Contains a ground wire terminal
-
Out of Stock
APOLLO Addressable Fire Alarm DISCOVERY UL OPEN-AREA SOUNDER VID – RED BODY (RED FLASH)
Read moreDiscovery UL Open-Area Sounder Visual Indicator with red body and red flash.
- UL 464 Certified
- 15 Pairs of Tones (EN54-3 Sounder)
- 7 Volume Levels
- Visual Indicator Beacon (Red-Flash)
- Discovery (works on XP95 & CoreProtocol)
-
Out of Stock
Gent Fire Alarm G017-01 Flush MCP 470 Ohms M1A-R470FG
Read moreManual call points from Honeywell Gent are easy and safe to operate, with no hammer required. Fully compliant with EN 54-11, each point is manufactured from ABS and both have a break glass and resettable element. For areas susceptible to inadvertent operation – such as sports halls – a stronger, clear polycarbonate cover version is available.
-
Out of Stock
Manual ‘No Break’ Call Point, surface Part No. BF370MR
Read more- Certified to EN54 Part 11 (LPCB/VdS).
- Unique ‘Plug & Play’ installation concept.
- Supplied with a non-breaking plastic resettable element.
- Includes a 470Ω resistor, test key and red back box.
- Anti-Tamper facility.
- Flush version (without a red back box) also available (order code BF370MFR).
Best offers
Join Risk Free
30 days refund
100% Safe
Secure Shopping
24x7 Support
Online 24 hours
Best Offers
Grab Now
Safe and Secured Payment
On all order over
Know Us
Safetech.hub is the newest online platform envisioned to provide 24/7 online platform for integrators, installers, and end users of Extra Low Voltage (ELV) systems in Nigeria
Read More
Reviews
There are no reviews yet.