Category
- Burglary Alarm System
- Cable
- Closed Circuit Television System (CCTV)
- Fire Equipment
- Pepper Spray Vault/ATM Protection System
- Personal Security
- Physical Access Control
Popular
- Gent Fire Alarm System Set of Keys for Key Switch Interface and MCP
- Gent Fire Alarm Vigilon Manual Call Point with Glass Element and Protective Cover (Excludes Back Box)
- Cutting-Edge Velocity Zeta Aspiration Smoke Detection Fire Alarm Panel
-
GENT ADDRESSABLE FIRE ALARM 1 TO 6 LOOP CONTROL PANEL
₦6,250,000.00₦6,170,000.00 -
TEXECOM VERITAS IMPAQ E BURGLAR ALARM VIBRATION DETECTOR- WHITE
₦22,000.00₦18,500.00 -
PAXTON ACCESS CONTROL NET2 PLUS 1 DOOR CONTROLLER – POE+, PLASTIC CABINET
₦462,000.00₦458,000.00 -
Concept Handheld Metal Detector with Vibration Function
₦20,000.00₦19,000.00 -
Fisher Research Labs M-scope Walk-Through Metal Detector
₦4,600,000.00₦4,500,000.00 -
CONCEPT (Burglar Alarm) WIRELESS SIGNAL REPEATER
₦23,500.00₦21,500.00 -
CONCEPT (Fire Alarm) TUYA WIFI SMOKE DETECTOR
₦13,000.00₦11,000.00
Gent Fire Alarm Interface Single Channel Output and Din Mounting Kit S4-34411
Gent S4-34411 Interface Single Channel Output and Din Mounting Kit
The S4-34411 from Gent is an Interface Single Channel Output and Din Mounting Kit.
Vigilon can accommodate a high quantity of loop powered interface units offering fexible range of inputs and outputs from the FD&A system from plant control and signalling other systems in a fi re, to linking with other emergency management systems such as sprinklers or security systems.
Gent S4-34411 Interface Single Channel Output and Din Mounting Kit
The S4-34411 from Gent is an Interface Single Channel Output and Din Mounting Kit.
Vigilon can accommodate a high quantity of loop powered interface units offering fexible range of inputs and outputs from the FD&A system from plant control and signalling other systems in a fi re, to linking with other emergency management systems such as sprinklers or security systems.
Loop powered interfaces offer a cost effective solution with each device individually addressed increasing the overall management capability of the FD&A system.
Interfaces are either powered from the loop or require a separate mains supply. The mains power version has its own battery backup.
Key Features
- Loop Powered devices reducing cost of installation and maintenance
- Individual addresses to maximise information and flexible cause and effect
- Each device with EN54-17 short circuit handling for enhanced system integrity
- Comprehensive range of functionality in each device variant to simplify system design
- Complete range of mounting enclosures and accessories
- Options to connect conventional fire detectors such as flame and beam detectors
- Certified to EN54-17 and EN54-18
Related products
-
Out of Stock
Manual ‘No Break’ Call Point, surface Part No. BF370MR
Read more- Certified to EN54 Part 11 (LPCB/VdS).
- Unique ‘Plug & Play’ installation concept.
- Supplied with a non-breaking plastic resettable element.
- Includes a 470Ω resistor, test key and red back box.
- Anti-Tamper facility.
- Flush version (without a red back box) also available (order code BF370MFR).
-
Out of Stock
APOLLO Addressable Fire Alarm DISCOVERY UL MANUAL PULL STATION BACKBOX
Read moreThe Discovery UL Manual Pull Station Backbox is used to allow surface mounting of the Discovery UL Manual Pull Station.
-
Out of Stock
Gent by Honeywell Fire Alarm Conversion Kit For VIG-NODE-24 EN 54 to BS V3+ Functionality (VIG-BSKIT-NODE)
Read moreGent VIG-BSKIT-NODE Conversion Kit
The VIG-BSKIT-NODE Conversion Kit for is designed for use with the VIG1-24 EN 54 to BS V3+ Functionality (Replaces VIG1-V3+) Loop Only.
Please Note: The BS or V3+ variants of Vigilon are no longer available. VIG-NODE-24 (EN54 version) panels may be converted to BS protocol using the conversion kit VIG-BSKIT-NODE.
-
Out of Stock
CTEC Fire Alarm CONVENTIONAL CFP Relay Output Card (Reset, Fault, Aux. & Remote Relay Outputs)
₦0.00Read more-
Product dimensions (mm) 82 W x 125 H x D 23mm. Weight 64g. Properties Single pole changeover contacts; Rated at 1A 50V; 50V Isolation between relays, contacts and CFP & relays; 27mA active relay coil current @ 27.6V supply.
-
Best offers
Join Risk Free
30 days refund
100% Safe
Secure Shopping
24x7 Support
Online 24 hours
Best Offers
Grab Now
Safe and Secured Payment
On all order over
Know Us
Safetech.hub is the newest online platform envisioned to provide 24/7 online platform for integrators, installers, and end users of Extra Low Voltage (ELV) systems in Nigeria
Read More
Reviews
There are no reviews yet.