Category
- Burglary Alarm System
- Cable
- Closed Circuit Television System (CCTV)
- Fire Equipment
- Pepper Spray Vault/ATM Protection System
- Personal Security
- Physical Access Control
Popular
- Gent Fire Alarm System Set of Keys for Key Switch Interface and MCP
- Gent Fire Alarm Vigilon Manual Call Point with Glass Element and Protective Cover (Excludes Back Box)
- Cutting-Edge Velocity Zeta Aspiration Smoke Detection Fire Alarm Panel
-
GENT ADDRESSABLE FIRE ALARM 1 TO 6 LOOP CONTROL PANEL
₦6,250,000.00₦6,170,000.00 -
TEXECOM VERITAS IMPAQ E BURGLAR ALARM VIBRATION DETECTOR- WHITE
₦22,000.00₦18,500.00 -
PAXTON ACCESS CONTROL NET2 PLUS 1 DOOR CONTROLLER – POE+, PLASTIC CABINET
₦462,000.00₦458,000.00 -
Concept Handheld Metal Detector with Vibration Function
₦20,000.00₦19,000.00 -
Fisher Research Labs M-scope Walk-Through Metal Detector
₦4,600,000.00₦4,500,000.00 -
CONCEPT (Burglar Alarm) WIRELESS SIGNAL REPEATER
₦23,500.00₦21,500.00 -
CONCEPT (Fire Alarm) TUYA WIFI SMOKE DETECTOR
₦13,000.00₦11,000.00
Output Expansion Relay Board Part No. EP212
₦0.00
-
- An optional system expansion device for use with the EP203 three zone automatic extinguisher panel.
- Mounts inside the EP203 panel to provide five volt free relay contacts (reset, mode, discharged, hold and abort).
- Reset relay switches during the panel’s reset cycle.
- Mode relay switches when the extinguishant system’s mode is changed to manual.
- Discharged relay switches when a released flow switch input (e.g. from the extinguishant pipework) is received to indicate the extinguishant has been released.
- Hold relay switches when a hold input is received at the panel. If the panel is in 2nd stage alarm (i.e. it is in automatic mode and detection circuits are activated, or it is in either automatic/manual mode and a manual release input is operated) the extinguishant release sequence is halted.
- Abort relay switches when an abort input is received at the panel to cancel the extinguishant release sequence.
Out of stock
Compare- An optional system expansion device for use with the EP203 three zone automatic extinguisher panel.
- Mounts inside the EP203 panel to provide five volt free relay contacts (reset, mode, discharged, hold and abort).
- Reset relay switches during the panel’s reset cycle.
- Mode relay switches when the extinguishant system’s mode is changed to manual.
- Discharged relay switches when a released flow switch input (e.g. from the extinguishant pipework) is received to indicate the extinguishant has been released.
- Hold relay switches when a hold input is received at the panel. If the panel is in 2nd stage alarm (i.e. it is in automatic mode and detection circuits are activated, or it is in either automatic/manual mode and a manual release input is operated) the extinguishant release sequence is halted.
- Abort relay switches when an abort input is received at the panel to cancel the extinguishant release sequence.
Product dimensions (mm) | TBC. |
Dimensions | 70 W x 160 H x 22 D mm. |
Weight | 62g. |
Properties | Single pole changeover contacts; Rated at 1A 30V DC. DO NOT use to switch Mains voltages. |
Related products
-
Out of Stock
C-tec Fire Alarm 24V 5A EN54-4 Switch Mode PSU Part No. BF562-5
Read more- Certified to EN54-4/A2 by the LPCB and VdS.
- A powerful 24V 5A switch mode/digital hybrid PSU that can be customised* to suit your exact requirements – see More Information tab for details.
- Plastic cover on PSU PCB guards against touching live parts.
- Includes a single-pole voltfree changeover relay that switches for any fault condition.
- Multiple indicators – supply present, general fault, fault type & aux. equipment fault.
- Two selectable battery charge currents.
- Battery fault impedance limits can be optimised to suit load current (helps extend battery life)*.
- Mains fail simulation mode.
- Improved on-board temperature sensor with optional remote sensor.
- Electronic functions comply with EN50131-6 grades 1-4 for security applications.
- BF562-5/E encased version also available.
-
Out of Stock
Manual ‘No Break’ Call Point, surface Part No. BF370MR
Read more- Certified to EN54 Part 11 (LPCB/VdS).
- Unique ‘Plug & Play’ installation concept.
- Supplied with a non-breaking plastic resettable element.
- Includes a 470Ω resistor, test key and red back box.
- Anti-Tamper facility.
- Flush version (without a red back box) also available (order code BF370MFR).
-
Out of Stock
Apollo Addressable Fire Alarm Series 65A Base – High-Performance Detector Mounting Solution
Read moreTwo-wire base
• Detector locking mechanism
• One-way fit
• Easy to wire
• Contains a ground wire terminal
• Contains no electric parts -
Solo 823-101 -Smoke & Cordless Heat Detector Test Set 9.3 Metres
₦2,523,000.00Add to cartSolo 823 Smoke & Cordless Heat Detector Test Set 9.3 metres Solo equipment is available in a number of conveniently arranged kits. Whether your need is for a simple starter kit, a universal smoke testing kit, or an all encompassing kit including a heat detector tester, there is one available. Larger kits are supplied with …
Solo 823-101 -Smoke & Cordless Heat Detector Test Set 9.3 MetresRead More
Best offers
Join Risk Free
30 days refund
100% Safe
Secure Shopping
24x7 Support
Online 24 hours
Best Offers
Grab Now
Safe and Secured Payment
On all order over
Know Us
Safetech.hub is the newest online platform envisioned to provide 24/7 online platform for integrators, installers, and end users of Extra Low Voltage (ELV) systems in Nigeria
Read More
Reviews
There are no reviews yet.