Category
- Burglary Alarm System
- Cable
- Closed Circuit Television System (CCTV)
- Fire Equipment
- Pepper Spray Vault/ATM Protection System
- Personal Security
- Physical Access Control
Popular
- Gent Fire Alarm System Set of Keys for Key Switch Interface and MCP
- Gent Fire Alarm Vigilon Manual Call Point with Glass Element and Protective Cover (Excludes Back Box)
- Cutting-Edge Velocity Zeta Aspiration Smoke Detection Fire Alarm Panel
-
GENT ADDRESSABLE FIRE ALARM 1 TO 6 LOOP CONTROL PANEL
₦6,250,000.00₦6,170,000.00 -
TEXECOM VERITAS IMPAQ E BURGLAR ALARM VIBRATION DETECTOR- WHITE
₦22,000.00₦18,500.00 -
PAXTON ACCESS CONTROL NET2 PLUS 1 DOOR CONTROLLER – POE+, PLASTIC CABINET
₦462,000.00₦458,000.00 -
Concept Handheld Metal Detector with Vibration Function
₦20,000.00₦19,000.00 -
Fisher Research Labs M-scope Walk-Through Metal Detector
₦4,600,000.00₦4,500,000.00 -
CONCEPT (Burglar Alarm) WIRELESS SIGNAL REPEATER
₦23,500.00₦21,500.00 -
CONCEPT (Fire Alarm) TUYA WIFI SMOKE DETECTOR
₦13,000.00₦11,000.00
QP412 4 Fire Alarm zone Conventional Control Panel
₦0.00
- Day/Night Mode Selection.
- Ground fault detection feature.
- 24V DC power output for external load.
- Zone EOL resistor can be set from panel board.
- Zone Output, Fault Output and Alarm Output (NO. NC. COM).
- System will back to normal automatically after alarm status is released.
- Removable front board for easy maintenance.
- Easy-to-clean front board is able to avoid dirt attached.
- High luminance and long life span LED.
- Independent visual & audible indication for zone open/short fault.
- Independent visual & audible indication for AC power & battery fault.
- Visual & audible indication for sounder short circuit fault.
- Buzzer silence with 3-mode operation feature.
- Accurate supervision circuit for battery.
Out of stock
Compare-
Characteristics
- Day/Night Mode Selection.
- Ground fault detection feature.
- 24V DC power output for external load.
- Zone EOL resistor can be set from panel board.
- Zone Output, Fault Output and Alarm Output (NO. NC. COM).
- System will back to normal automatically after alarm status is released.
- Removable front board for easy maintenance.
- Easy-to-clean front board is able to avoid dirt attached.
- High luminance and long life span LED.
- Independent visual & audible indication for zone open/short fault.
- Independent visual & audible indication for AC power & battery fault.
- Visual & audible indication for sounder short circuit fault.
- Buzzer silence with 3-mode operation feature.
- Accurate supervision circuit for battery.
Model QP412 Zone 4 zone Power 220V AC, 50/60Hz *Others also available Battery Capacity 24V /1.2Ah Max. Output Current 2.0 A # of heat detectors connected No limit *Except electronic-type # of smoke detectors connected 20/zone *Horing Lih manufactured End of Line Resistor 4.7 kΩ Material 1.2mm steel plate Dimensions (H x W x D) mm 203 x 272 x 71 Optional Device
Optional battery 1.2Ah
Categories: Control panel, Conventional Fire Alarm, Fire Alarm System, Fire Equipment
Related products
-
C-TEC Fire Alarm CONVENTIONAL ActiV Diode Base Part No. C4408D
₦4,500.00₦3,000.00Add to cart-
- Compatible with C-TEC’s entire range of ActiV fire detectors.
- Third-party certified to the relevant parts of EN54 in conjunction with our ActiV detectors.
- Easy to fit with lots of working space.
- Can be ceiling mounted in any orientation due to the true 360° degree viewing angle of the LED indicator strips on all ActiV detectors.
- Integrated detector/base locking mechanism, head removal tool and ID tag.
- Simple ‘click and twist’ design.
- Remote LED terminals for the optional connection to a BF318 Remote indicator.
- C4408 non-diode and C4408R relay bases also available.
-
-
Out of Stock
Manual ‘No Break’ Call Point, surface Part No. BF370MR
Read more- Certified to EN54 Part 11 (LPCB/VdS).
- Unique ‘Plug & Play’ installation concept.
- Supplied with a non-breaking plastic resettable element.
- Includes a 470Ω resistor, test key and red back box.
- Anti-Tamper facility.
- Flush version (without a red back box) also available (order code BF370MFR).
-
Out of Stock
Apollo Addressable Fire Alarm E-Z Fit Base – 6″ Ultra-Low Profile Detector Mount
Read more- Four-wire base
- Detector locking mechanism
- One way fit
- Easy to wire
- Contains a ground wire terminal
-
Out of Stock
APOLLO Addressable Fire Alarm DISCOVERY UL MANUAL PULL STATION BACKBOX
Read moreThe Discovery UL Manual Pull Station Backbox is used to allow surface mounting of the Discovery UL Manual Pull Station.
Best offers
Join Risk Free
30 days refund
100% Safe
Secure Shopping
24x7 Support
Online 24 hours
Best Offers
Grab Now
Safe and Secured Payment
On all order over
Know Us
Safetech.hub is the newest online platform envisioned to provide 24/7 online platform for integrators, installers, and end users of Extra Low Voltage (ELV) systems in Nigeria
Read MoreBlog Updates
Tips to Consider While Selecting a Fire Alarm System
July 4, 2023
Discover 2024’s Top 5 Affordable Security Systems Under 70k Naira
December 6, 2023
Unveiling the Top 5 Security Measures for Enhanced Estate Security
December 5, 2023