Category
- Burglary Alarm System
- Cable
- Closed Circuit Television System (CCTV)
- Fire Equipment
- Pepper Spray Vault/ATM Protection System
- Personal Security
- Physical Access Control
Popular
- Gent Fire Alarm System Set of Keys for Key Switch Interface and MCP
- Gent Fire Alarm Vigilon Manual Call Point with Glass Element and Protective Cover (Excludes Back Box)
- Cutting-Edge Velocity Zeta Aspiration Smoke Detection Fire Alarm Panel
-
GENT ADDRESSABLE FIRE ALARM 1 TO 6 LOOP CONTROL PANEL
₦6,250,000.00₦6,170,000.00 -
TEXECOM VERITAS IMPAQ E BURGLAR ALARM VIBRATION DETECTOR- WHITE
₦22,000.00₦18,500.00 -
PAXTON ACCESS CONTROL NET2 PLUS 1 DOOR CONTROLLER – POE+, PLASTIC CABINET
₦462,000.00₦458,000.00 -
Concept Handheld Metal Detector with Vibration Function
₦20,000.00₦19,000.00 -
Fisher Research Labs M-scope Walk-Through Metal Detector
₦4,600,000.00₦4,500,000.00 -
CONCEPT (Burglar Alarm) WIRELESS SIGNAL REPEATER
₦23,500.00₦21,500.00 -
CONCEPT (Fire Alarm) TUYA WIFI SMOKE DETECTOR
₦13,000.00₦11,000.00
Zeta Addressable Fire Alarm Loop CardFModule (SCM-LCM)
₦290,000.00 ₦278,000.00
Designed to EN54 requirements
Supports up to 250 addresses
“Heartbeat LED” that shows communication between
the module and the motherboard
Extensive front unit status indications
Time saving AUTO-LEARN facility
Quick and easy to install
450mA max load (at 20 ohms loop resistance)
Double address detection
Revolutionize Your Security System with the SCM-LCM Module – Zeta’s Finest
Introducing the Zeta Loop Card Module (SCM-LCM)
Unlock the power of seamless communication and monitoring for your analogue addressable devices with the SCM-LCM module. This plug-and-play marvel is designed to make your life easier, ensuring your systems are not only efficient but also effortlessly manageable.
Elevate Your System
Unmatched Connectivity
The SCM-LCM module boasts the ability to connect up to 250 addresses with a maximum load capacity of 450mA, ensuring that your system can handle the most demanding tasks.
Effortless Addressing
Say goodbye to complicated addressing procedures. You can either address your loop devices via an 8-way DIP switch or use the user-friendly MKIITOOL handheld programming tool. This innovative feature minimizes errors and significantly reduces installation time, making it a game-changer for installers.
Auto-Learn for Efficiency
The Auto-Learn function takes the hassle out of device installation and configuration changes. Let your system do the work by learning which devices are connected and even helping you locate wiring faults on the loop. Say hello to effortless maintenance!
Premium Features
Designed to Perfection
Our SCM-LCM module is designed to meet EN54 requirements, ensuring top-notch quality and compliance with industry standards.
Visual Clarity
The “Heartbeat LED” provides a visual indication of seamless communication between the module and the motherboard. You can trust that your system is always up and running.
Status at a Glance
Stay in control with extensive front unit status indications. Monitor your system’s health effortlessly.
Quick Installation
Save time on installation with the SCM-LCM module. It’s quick and easy to set up, allowing you to focus on what matters most.
Double the Assurance
With double address detection, you can trust that your system is as secure as possible.
Specification SCM-LCM
- Part No: 37-391
- Design Standard: EN54
- Approval: LPCB (Pending)
- Rated Voltage: 30VDC Nominal
- Maximum Loop Current: 450mA
- Maximum Loop Resistance: 50Ω (25Ω per core)
- Maximum SLC Capacity: 250 Addresses
- Maximum SLC Cable Length: 2KM
- Maximum SLC Capacitance: 500nF
- Maximum SLC Baud Rate: 1024 bits per second (typical)
- Operating Temperature: -5°C to 40°C
- Max Humidity: 93% Non-Condensing
- Size (mm) (HxWxD): 105mm x 57mm x 47mm
- Weight: 0.15KG
- Recommended Cable Sizes: 0.8mm2 to 2.5mm2
Compatible Devices/Accessories
Enhance your system further with these compatible devices and accessories:
- MKII-AOP: Addressable smoke detector
- MKII-AOH: Addressable opto-heat detector
- MKII-AHR: Addressable rate of rise heat detector
- MKII-AHF: Addressable fixed heat detector (57°C)
- MKII-AHF/CS90: Addressable fixed heat detector (90°C)
- ZT-CP3/AD: Addressable call point
- ZAI-MI: Addressable input unit
- ZAIO-MI: Addressable input / Output unit
- ZAZM-MI: Addressable zone Monitor
- ZASC-MI: Addressable sounder circuit controller
- MKII-SSB: Sandwich Sounder base
- MKII-AXT/x: Addressable Xtratone Sounder
- MKII-AXTB/x: Addressable Xtratone Sounder Beacon
- ZRAP/x: Addressable Raptor Sounder
- ZRAPB/x: Addressable Raptor Sounder Beacon
- SMM/B: Mini Module (for Beam detector)
- SMM/C: Mini Module (call point Monitor)
- Wireless transponder
- Wireless detector base
- Wireless call point
- Wireless I/O
- Wireless Sounder
Elevate your security and monitoring system with the Zeta Loop Card Module (SCM-LCM). Unleash the power of seamless communication and unmatched efficiency. Invest in the future of security today!
Weight | 0.2 kg |
---|---|
Dimensions | 1.0 × 0.5 × 0.5 cm |
Related products
-
Out of Stock
Manual ‘No Break’ Call Point, surface Part No. BF370MR
Read more- Certified to EN54 Part 11 (LPCB/VdS).
- Unique ‘Plug & Play’ installation concept.
- Supplied with a non-breaking plastic resettable element.
- Includes a 470Ω resistor, test key and red back box.
- Anti-Tamper facility.
- Flush version (without a red back box) also available (order code BF370MFR).
-
Out of Stock
C-tec Fire Alarm 24V 5A EN54-4 Switch Mode PSU Part No. BF562-5
Read more- Certified to EN54-4/A2 by the LPCB and VdS.
- A powerful 24V 5A switch mode/digital hybrid PSU that can be customised* to suit your exact requirements – see More Information tab for details.
- Plastic cover on PSU PCB guards against touching live parts.
- Includes a single-pole voltfree changeover relay that switches for any fault condition.
- Multiple indicators – supply present, general fault, fault type & aux. equipment fault.
- Two selectable battery charge currents.
- Battery fault impedance limits can be optimised to suit load current (helps extend battery life)*.
- Mains fail simulation mode.
- Improved on-board temperature sensor with optional remote sensor.
- Electronic functions comply with EN50131-6 grades 1-4 for security applications.
- BF562-5/E encased version also available.
-
Solo 100-001- Fibreglass 4 Section Telescopic Pole – 4.5 metres
₦685,000.00₦675,000.00Add to cart- SOLO 100/108 Telescopic Poles
- Exceptionally lightweight and very portable
- Lock system as standard named “Totalock”
- Non Conductive Material
- Makes the job more efficient
- Strong & Durable Fibreglass
- Can be used with all SOLO tools and attachments
- Use with tools up to 6 metres (Including Height of Man)
- Add SOLO 101-001 Extension poles to reach 9 metres (Including Height of Man)
-
Out of Stock
Apollo Addressable Fire Alarm Series 65A Base – High-Performance Detector Mounting Solution
Read moreTwo-wire base
• Detector locking mechanism
• One-way fit
• Easy to wire
• Contains a ground wire terminal
• Contains no electric parts
Best offers
Join Risk Free
30 days refund
100% Safe
Secure Shopping
24x7 Support
Online 24 hours
Best Offers
Grab Now
Safe and Secured Payment
On all order over
Know Us
Safetech.hub is the newest online platform envisioned to provide 24/7 online platform for integrators, installers, and end users of Extra Low Voltage (ELV) systems in Nigeria
Read More
Reviews
There are no reviews yet.