Category
- Burglary Alarm System
- Cable
- Closed Circuit Television System (CCTV)
- Fire Equipment
- Pepper Spray Vault/ATM Protection System
- Personal Security
- Physical Access Control
Popular
- Gent Fire Alarm System Set of Keys for Key Switch Interface and MCP
- Gent Fire Alarm Vigilon Manual Call Point with Glass Element and Protective Cover (Excludes Back Box)
- Cutting-Edge Velocity Zeta Aspiration Smoke Detection Fire Alarm Panel
-
GENT ADDRESSABLE FIRE ALARM 1 TO 6 LOOP CONTROL PANEL
₦6,250,000.00Original price was: ₦6,250,000.00.₦6,170,000.00Current price is: ₦6,170,000.00. -
TEXECOM VERITAS IMPAQ E BURGLAR ALARM VIBRATION DETECTOR- WHITE
₦22,000.00Original price was: ₦22,000.00.₦18,500.00Current price is: ₦18,500.00. -
PAXTON ACCESS CONTROL NET2 PLUS 1 DOOR CONTROLLER – POE+, PLASTIC CABINET
₦462,000.00Original price was: ₦462,000.00.₦458,000.00Current price is: ₦458,000.00. -
Concept Handheld Metal Detector with Vibration Function
₦20,000.00Original price was: ₦20,000.00.₦19,000.00Current price is: ₦19,000.00. -
Fisher Research Labs M-scope Walk-Through Metal Detector
₦4,600,000.00Original price was: ₦4,600,000.00.₦4,500,000.00Current price is: ₦4,500,000.00. -
CONCEPT (Burglar Alarm) WIRELESS SIGNAL REPEATER
₦23,500.00Original price was: ₦23,500.00.₦21,500.00Current price is: ₦21,500.00. -
CONCEPT (Fire Alarm) TUYA WIFI SMOKE DETECTOR
₦13,000.00Original price was: ₦13,000.00.₦11,000.00Current price is: ₦11,000.00.
Zeta Fire Alarm Intrinsically Safe Optical Smoke Detector (ZIS-OSD)
- Intrinsically Safe Design: The ZIS-OSD is purpose-built for installation in explosion-prone zones, guaranteeing safe operation even in high-risk areas.
- Resilient to Environmental Variations: Thanks to its analog compensation system, this detector demonstrates exceptional resistance to atmospheric pressure fluctuations, temperature changes, and humidity levels.
- Tyndall Effect Technology: The ZIS-OSD operates on the principles of the Tyndall effect, which involves measuring infrared light scattered by smoke particles within an enclosed measuring chamber, eliminating interference from external light sources.
- Self-Regulating Sensitivity: Equipped with a built-in digital system, the detector maintains consistent sensitivity, even as dirt accumulates within the measuring chamber. It triggers an alarm signal when the preset regulation threshold is exceeded, prompting the need for periodic optical system maintenance.
- Replaceable Optical Chamber: The ZIS-OSD features a user-friendly design with a replaceable optical chamber. When cleaning or replacement becomes necessary, this feature simplifies maintenance.
Intrinsically Safe Optical Smoke Detector – Zeta ZIS-OSD
Product Description:
Ensure the safety of your workspace or environment with the Zeta Intrinsically Safe Optical Smoke Detector (ZIS-OSD). Designed for early fire detection, this advanced smoke detector is engineered to sense visible smoke at the incipient stage of a fire, well before flames become evident and temperatures rise significantly. In environments where normal conditions exclude smoke, dust, and steam condensation, the ZIS-OSD stands as your vigilant sentinel, offering reliable protection against potential hazards.
Key Features:
- Intrinsically Safe Design: The ZIS-OSD is purpose-built for installation in explosion-prone zones, guaranteeing safe operation even in high-risk areas.
- Resilient to Environmental Variations: Thanks to its analog compensation system, this detector demonstrates exceptional resistance to atmospheric pressure fluctuations, temperature changes, and humidity levels.
- Tyndall Effect Technology: The ZIS-OSD operates on the principles of the Tyndall effect, which involves measuring infrared light scattered by smoke particles within an enclosed measuring chamber, eliminating interference from external light sources.
- Self-Regulating Sensitivity: Equipped with a built-in digital system, the detector maintains consistent sensitivity, even as dirt accumulates within the measuring chamber. It triggers an alarm signal when the preset regulation threshold is exceeded, prompting the need for periodic optical system maintenance.
- Replaceable Optical Chamber: The ZIS-OSD features a user-friendly design with a replaceable optical chamber. When cleaning or replacement becomes necessary, this feature simplifies maintenance.
Specifications:
- Model: ZIS-OSD
- Part Number: 84-100
- Voltage: 12V to 28V
- Maximum Monitoring Mode Current: ≤ 60 μA
- Alarm Current: 20 mA
- Detectable Test Fires: TF1 to TF5 and TF8
- Operating Temperature Range: -25°C to +55°C
- Relative Humidity: Up to 95% at 40°C
- Color: Black
- Dimensions (with base): 115 mm (Diameter) x 54 mm (Height)
- Weight: 0.15 kg
Installation Information:
The ZIS-OSD is compatible with Zeta-manufactured fire alarm system detector lines and should be installed behind a suitable spark-proof separator for optimal safety.
Ensure the utmost safety in your industrial or commercial setting with the Zeta Intrinsically Safe Optical Smoke Detector (ZIS-OSD). Don’t compromise on fire detection and prevention—invest in Zeta’s trusted technology today.
Related products
-
C-TEC Fire Alarm CONVENTIONAL ActiV Diode Base Part No. C4408D
₦4,500.00Original price was: ₦4,500.00.₦3,000.00Current price is: ₦3,000.00.Add to cart-
- Compatible with C-TEC’s entire range of ActiV fire detectors.
- Third-party certified to the relevant parts of EN54 in conjunction with our ActiV detectors.
- Easy to fit with lots of working space.
- Can be ceiling mounted in any orientation due to the true 360° degree viewing angle of the LED indicator strips on all ActiV detectors.
- Integrated detector/base locking mechanism, head removal tool and ID tag.
- Simple ‘click and twist’ design.
- Remote LED terminals for the optional connection to a BF318 Remote indicator.
- C4408 non-diode and C4408R relay bases also available.
-
-
Out of Stock
APOLLO Addressable Fire Alarm XPERT 7 BASE 4″ – ISOLATING
Read moreThe base senses short-circuit faults on Discovery loops and spurs and minimises disruption from short circuits.
- Detects wiring short-circuits
- High brightness LED
- Up to 20 detectors or their equivalent load, may be installed between isolating bases
-
Out of Stock
Gent Fire Alarm G017-01 Flush MCP 470 Ohms M1A-R470FG
Read moreManual call points from Honeywell Gent are easy and safe to operate, with no hammer required. Fully compliant with EN 54-11, each point is manufactured from ABS and both have a break glass and resettable element. For areas susceptible to inadvertent operation – such as sports halls – a stronger, clear polycarbonate cover version is available.
-
Solo 823-101 -Smoke & Cordless Heat Detector Test Set 9.3 Metres
₦2,523,000.00Add to cartSolo 823 Smoke & Cordless Heat Detector Test Set 9.3 metres Solo equipment is available in a number of conveniently arranged kits. Whether your need is for a simple starter kit, a universal smoke testing kit, or an all encompassing kit including a heat detector tester, there is one available. Larger kits are supplied with …
Solo 823-101 -Smoke & Cordless Heat Detector Test Set 9.3 MetresRead More
Best offers
Join Risk Free
30 days refund
100% Safe
Secure Shopping
24x7 Support
Online 24 hours
Best Offers
Grab Now
Safe and Secured Payment
On all order over
Know Us
Safetech.hub is the newest online platform envisioned to provide 24/7 online platform for integrators, installers, and end users of Extra Low Voltage (ELV) systems in Nigeria
Read More
Reviews
There are no reviews yet.