Category
- Uncategorized
- Access Control and Time Attendance System
- Accessories
- Addressable base
- Audio
- Cable
- Call Point
- Cameras
- Closed Circuit Television System (CCTV)
- Computer & Laptop
- Door controller
- Fire Alarm System
- Home Appliances
- Manual Callpoints
- Metal Detector
- Naso mask
- New Arrival
- Night Vision
- On Sale
- Security Alarm System
Popular
-
C-Tec FP 8 Zone Conventional Fire Alarm Panel-Ff388-2
₦125,000.00₦120,000.00 -
SOCA SL-130 Dead Bolt Lock ( All purpose type )
₦15,000.00₦13,000.00 -
SOCA SL-100D Dead Bolt Lock ( for automatic door)
₦18,000.00₦15,000.00 - SOCA SL 100A Dead Bolt ₦15,000.00
- Soca SD-30 Armored Door Loop
Tag Clouds
Zeta ZIOU/230 Interface Module Loop Powered (5.0A Rating)
The Mains IO Modules are fully monitored loop powered devices which permit the interfacing of third-party equipment with the Fire Alarm Control panel using normally open dry contact connections.
Zeta ZIOU/230 Interface Module Loop Powered (5.0A Rating)
The Mains IO Modules are fully monitored loop powered devices which permit the interfacing of third-party equipment with the Fire Alarm Control panel using normally open dry contact connections.
The connection to the input is monitored for fault (open or short circuit) and Alarm conditions.
The interface is used to monitor the contacts of an external system which must be interfaced to the Fire Alarm System, for example a Flow Switch in a sprinkler system to indicate if the sprinklers have been activated or extinguishant level monitoring in Gas Extinguishing systems, etc.
Module is provided with a loop short-circuit isolator and with a voltage free single pole change over mains rated output.
The output relay is always powered directly from the detection loop. It is not required to use an external 24V DC power supply. Relay operation is confirmed by an on-board red LED. An 8 way D.I.L switch is provided to configure the module’s address.
This value can be set in the range 1 to 125. The following programmable functions are available: Input Activation Mode, Delayed Input Alarm Activation, Output Delayed Activation.
The Simplicity CO 8 range is designed to detect & monitor CO concentrations in places such as warehouses, car parks, tunnels and enclosed buildings where forklifts, cars and delivery trucks can produce deadly amounts of carbon monoxide, in high traffic areas Carbon Monoxide can accumulate in these areas and can be a serious safety and health concern.
Key Features
- Fast Activation Response
- Loop Powered
- Five Status LEDs provided
- Low Power Consumption
- Module features an integral short-circuit loop isolator
- Single mains rated relay contact
Dimensions | 28.2 × 13.4 cm |
---|
Related products
-
Zeta Fyreye MkII Conventional Heat Detectors MKII-HF C/W Base
₦17,000.00₦15,000.00Add to cartDESCRIPTION
The Fyreye fixed heat detector (MKII-HF) has a
single thermistor arrangement that gives an alarm at a
temperature of 57°C.
There are 4 types of mounting base available; standard
or deep and with or without diode. -
Gent Flush Manual Call Point (XENS-850) 470 Ohms Glass
Read moreGent XENS-850 Flush Manual Call Point 470 Ohms Glass
Gent Flush Manual Call Point are designed to provide a manual alarm interface to conventional fire alarm control panels. All call points are supplied in the standard red colour and are available in semi-flush mounting or surface mounting options. The manual call points are all with a 470 Ohm resistor and Normally Open contact, complete with glass.
Both break glass, and resettable operating elements can be used in the standard unit by a yellow strip on the element which becomes visible when activated.
With the addition of a hinged transparent cover the element may be protected against accidental operation.
A specialist test key may be inserted into the bottom of the unit to lower the glass and release the micro-switch and thus a full functional test is achieved.
-
Gent by Honeywell VESDA-E VEA-40 Aspirating Smoke Detector with LED Displays(VEA-040-A00)
Read morecombine VESDA reliability and early warning smoke detection with pinpoint addressability and a variety of annunciation options that truly surpass traditional spot detectors.
They use patented air sampling points and multichannel microbore air-sampling with three alarm sensitivity settings for the sampling points. As a
multi-channel, addressable system, the VEA detector is able to divide a
protected space into sampling locations, enabling the localization of potential sources of fire for faster incident response. The detectors are suitable for
protection of areas where pinpoint location of fire events is essential, thus providing ideal fire detection solutions for healthcare, offices, education, retail, prisons and electrical cabinets. A wide range of features provide flexibility, field programmability, enhanced connectivity and reduced total cost of ownership. -
Gent Single Mode Fibre Network Card (VIG-NC-SMF)
₦440,000.00Add to cartThe Single Mode Fibre Network Card (VIG-NC-SMF) allows a fast and reliable network over distances of up to 20km between Vigilon Plus Panels (VIGPLUS-24, VIGPLUS-72) / Network Nodes (VIGPLUS-NODE).
The Single Mode Fibre Network card is designed to plug into the backplane of a panel or node in dedicated slots.
Fibre optic connects directly to the sockets on the card.
Up to 31 panels/nodes on a single network.
Up to 200 panels/nodes on a complex networks.
Popular Tags
Best offers
Join Risk Free
30 days refund
100% Safe
Secure Shopping
24x7 Support
Online 24 hours
Best Offers
Grab Now
Free Shiping
On all order over
Know Us
Safetech.hub is the newest online platform envisioned to provide 24/7 online platform for integrators, installers, and end users of Extra Low Voltage (ELV) systems in Nigeria
Read More
Reviews
There are no reviews yet.