Category
- Uncategorized
- Access Control and Time Attendance System
- Accessories
- Addressable base
- Audio
- Cable
- Call Point
- Cameras
- Closed Circuit Television System (CCTV)
- Computer & Laptop
- Door controller
- Fire Alarm System
- Home Appliances
- Manual Callpoints
- Metal Detector
- Naso mask
- New Arrival
- Night Vision
- On Sale
- Security Alarm System
Popular
-
C-Tec FP 8 Zone Conventional Fire Alarm Panel-Ff388-2
₦125,000.00₦120,000.00 -
SOCA SL-130 Dead Bolt Lock ( All purpose type )
₦15,000.00₦13,000.00 -
SOCA SL-100D Dead Bolt Lock ( for automatic door)
₦18,000.00₦15,000.00 - SOCA SL 100A Dead Bolt ₦15,000.00
- Soca SD-30 Armored Door Loop
Tag Clouds
ZETA Fyreye Ultra-Violet Flame Detector (FEUV2000)
₦35,000.00
-
- Low profile shape
- The detector is solar blind and incorporates an electronic filter to eliminate unwanted alarms from naturally occurring phenomena
- Fast response time
- High immunity to electrical noise & RF interference
Fyreye Ultra-Violet Flame Detector
The Fyreye ultra-violet flam detector is particularly suited to applications where flames can be expected to develop initially rather than smoke. This is typically due to the nature of the materials being protected for instance camera film, computer, audio & videotapes or disks.
The detector is for indoor use only and should not be exposed to spurious sources of UV, such as sparks, uncovered halogen lights, lightning, etc. as these may trigger a false alarm.
Due to the operational nature of flame detectors, it is generally recommended to fit just one detector per zone.
Technical Specification
- Model:Â FEUV2000
- Input Voltage:Â 12-28 V DC
- Quiescent Current: 320 цA
- Operating Temperature: 0°C to 45°C
- Max. Wind Speed:Â Not affected
- Storage Temperature: -25°C to 80°C
- Alarm Current:Â 45-50 mA
- Detection Angle: 120°
- UV Sensitivity: 185 – 260 nm
- Response Time:Â 10 sec for 30 mm flame @ 4 metres
- Size (W x H x D mm):Â 98 X 98 X 36
- Weight:Â 85 g
Model Number | Description | Datasheets & Manuals |
---|---|---|
FEUV2000 | Fyreye Conventional Ultra-Violet Flame Detector | Datasheet |
Dimensions | 9.8 × 9.8 × 3.6 cm |
---|
Related products
-
C-TEC ActiV Relay Base with Diode Part No. C4408DR
Read more-
- Compatible with C-TEC’s entire range of ActiV fire detectors.
- Includes a 1A @ 24 VDC relay controlled by detector’s remote LED output.
- Ideal for switching CCTV, security and door retaining systems.
- Third-party certified to the relevant parts of EN54 in conjunction with our ActiV detectors.
- Easy to fit with lots of working space.
- Can be ceiling mounted in any orientation due to the true 360° degree viewing angle of the LED indicator strips on all ActiV detectors.
- Integrated detector/base locking mechanism, head removal tool and ID tag.
- Simple ‘click and twist’ design.
- Remote LED terminals for the optional connection to a BF318 Remote indicator.
- C4408R non-diode relay base also available for use on systems that do not require head out monitoring.
-
-
Zeta Fyreye MkII Conventional Heat Detectors MKII-HF C/W Base
₦17,000.00₦15,000.00Add to cartDESCRIPTION
The Fyreye fixed heat detector (MKII-HF) has a
single thermistor arrangement that gives an alarm at a
temperature of 57°C.
There are 4 types of mounting base available; standard
or deep and with or without diode. -
Zeta ID2/2/M Infinity ID2 Intelligent 2 Wire 2 Zone Fire Panel in Metal Enclosure
Read moreDESCRIPTION
Zeta Alarm Systems is proud to introduce the most advanced 2 wire system on the market. We can now provide a system that gives all of the benefits associated with a ‘2 Wire’ installation (less cable, quicker installation, cost savings on labour/product) and has the facility to ‘I.D.’ the devices.
The system is built on the proven communication protocol developed by Zeta Alarm Systems and shares the same platform as our largest, most powerful system.
The ID2 can be used for new installations, as a retrofit for any conventional system or as a replacement for existing 2 wire systems when the extra features are deemed to be desirable/necessary. This is possible because the ID2 devices sit on radial circuits, thus making it easy to ‘upgrade’ a system with the facility to I.D. devices without the need to re-wire.
Zeta Alarm Systems is proud to introduce the most advanced 2 wire system on the market. We can now provide a system that gives all of the benefits associated with a ‘2 Wire’ installation (less cable, quicker installation, cost savings on labour/product) and has the facility to ‘I.D.’ the devices.
-
Gent 4 ZONE CONVENTIONAL PANEL, EN54 LESS BATTERIES (13270-04LB)
₦259,000.00₦235,500.00Add to cartDESCRIPTION
Gent 13270-04LB 4 Zone Conventional Xenex Fire Panel
BSI approved to EN54: Parts 2 & 4, the Xenex control panel can be used on installations meeting BS 5839:Part1. Control panel options for 2-8 zones can be specified.
Designed to simplify system installation, each Xenex panel contains an integral power supply and battery support to drive up to 8 alarm sounder circuits, 2 auxiliary relay contacts, a zone disablement facility and also one-man test and commissioning features.
Popular Tags
Best offers
Join Risk Free
30 days refund
100% Safe
Secure Shopping
24x7 Support
Online 24 hours
Best Offers
Grab Now
Free Shiping
On all order over
Know Us
Safetech.hub is the newest online platform envisioned to provide 24/7 online platform for integrators, installers, and end users of Extra Low Voltage (ELV) systems in Nigeria
Read More
Reviews
There are no reviews yet.