• C-TEC Manual IP67 ‘Crack Glass’ Call Point, surface Part No. BF370/W

    • Certified to EN54 Part 11 (LPCB/VdS).
    • Weather resistant and sealed to IP67.
    • Ideal for use in external environments where water and dirt are likely to be present.
    • Unique ‘Plug & Play’ installation concept.
    • Supplied with a glass element.
    • Includes a 470Ω resistor and test key.
    • Anti-Tamper facility.
    • Wide -25ºC to +70ºC operating range.
  • C-TEC STI Call Point Stopper, Flush Mount Part No. STI-6930

    • Protective cover for flush mounted manual call points.
    • Helps prevent accidental or malicious call point activation.
    • Comprises a clear, tamper proof call point cover c/w red header labelled ‘IN CASE OF FIRE LIFT COVER – BREAK GLASS’.
    • Surface version (ST-6931) and green versions also available (see variants tab below).
    • Main picture shows Call Point Stopper with a Manual Call Point. The call point is NOT supplied.

    Download datasheet

  • C-TEC Yellow Extinguishant Release Call Point, Surface Part No. BF372

  • C-TEC Retrofit Decor Plate Part No. BF-DP

    • An easy-to-fit 152mm diameter mounting accessory for use with ceiling mounted ActiV or CAST devices.
    • Helps cover the decorating witness marks left by Grade D type Mains/Battery Alarms on system retrofits.
    • Includes multiple mounting holes and a large cable entry section.
    • Two K40x12 Pozi Flange PT retaining screws are supplied to secure the C-TEC ActiV or CAST device directly to the BF-DP.
  • C-TEC Power Supply Configurator Part No. BF423

    • Allows C-TEC’s BF560 and BF562 range of boxed, caged and PCB-only EN54-4/A2 Power Supplies to be optionally customised to suit an application.
    • Configurable PSU parameters include Float voltage temperature compensation; Battery charge rate (mA); Battery impedance; Input/Output settings.
    • Intuitive and easy-to-use with comprehensive Help files.
    • Requires a PC running Windows XP, Vista, 7 or 8.
    • Includes a Configurator, software CD, mini-USB to standard-USB connection lead and a 1.3mm to 1.3mm connection lead c/w adaptor.
    • IMPORTANT: Changing a PSU’s parameters will render its EN54-4/A2 approval obsolete and any changes must be tested by the responsible person for correct operation.
    • Free software updates available via our Software Page
  • C-TEC STU Mounting Plate for BF360/12 or BF560/12 12V 2A PSU Part No. BF360SP

    • Facilitates the mounting of a third-party Subscriber Terminal Unit (STU) in a BF360-12 or BF560/12 12V 2A PSU.
    • Finished in 1.2mm steel.
    • Accessory pack includes installation instructions, mounting screws, fixing pads, cable clip and cable tie.
    • Can also be used with a BF360-24 or BF560-24 1.5A 24V PSU by using an ancillary BF360BOX enclosure mounted alongside the PSU.

    Download datasheet

     

  • C-TEC Single Gang Surface Interface Plate, shallow (20mm) Part No. NCP-23

  • C-TEC Single Gang Surface Interface Plate, deep (25mm) Part No. NCP-24

    • Allows standard UK single gang plated products to be fixed to most European style back boxes (square and round variants).
    • Adapts to most European fixing centres – see video for further details.
    • Multiple variants available – options include single gang shallow (NCP23), single gang deep (NCP24), double gang shallow (NCP25) and double gang deep (NCP26).
    • Designed to match C-TEC’s existing plastics and colours.
    • Tough and durable.
    • Can also be surface mounted directly to a wall.
  • C-TEC Red Plastic Fire Panel Key

    • A spare plastic S-KEY for use C-TEC’s CFP, XFP and ZFP fire panels.
    • Provides authorised users with access to a fire panel’s authorised user controls.
    • Finished in red polycarbonate for extra strength.
    • See tech. specs below for full panel compatibility details
  • C-TEC CFP AlarmSense 8 Zone Two-Wire Fire Alarm Panel

    • Third-party certified to EN54 parts 2 and 4 by the Loss Prevention Certification Board (LPCB).

    • Intuitive user-friendly interface with colour-coded buttons and combined keypad/keyswitch entry.

    • Manufactured by C-TEC in the UK.

    • Eight AlarmSense zone circuits – compatible with Apollo’s AlarmSense detectors, call points, sounders and visual indicators.

    • Four conventional sounder circuits.

    • Integral 1.5A EN54-4/A2 compliant switch mode PSU.

    • Wide range of engineering functions including zone test, coincidence, zone delay and non-latching zones.

    • Two on-board relays (Fire and Fault).

    • Two open-collector outputs (Remote and Reset).

    • ‘Class change’ and alert inputs.

    • Installer-friendly design.

    • Attractive flush or surface mountable plastic lid and enclosure – no bezel required.

    • Low 25mA quiescent current.

    • Multiple indicators.

    • System expansion connections provided for up to eight two-wire repeaters (one CFP761 network card required per system).

    • Space for two x 12V 3.3Ah VRLA batteries.

     295,000.00 300,000.00
    Buy now
  • C-TEC CFP AlarmSense 4 Zone Two-Wire Fire Alarm Panel

    • Third-party certified to EN54 parts 2 and 4 by the Loss Prevention Certification Board (LPCB).

    • Intuitive user-friendly interface with colour-coded buttons and combined keypad/keyswitch entry.

    • Manufactured by C-TEC in the UK.

    • Two AlarmSense zone circuits – compatible with Apollo’s AlarmSense detectors, call points, sounders and visual indicators.

    • Four conventional sounder circuits.

    • Integral 1.5A EN54-4/A2 compliant switch mode PSU.

    • Wide range of engineering functions including zone test, coincidence, zone delay and non-latching zones.

    • Two on-board relays (Fire and Fault).

    • Two open-collector outputs (Remote and Reset).

    • ‘Class change’ and alert inputs.

    • Installer-friendly design.

    • Attractive flush or surface mountable plastic lid and enclosure – no bezel required.

    • Low 25mA quiescent current.

    • Multiple indicators.

    • System expansion connections provided for up to eight two-wire repeaters (one CFP761 network card required per system).

    • Space for two x 12V 3.3Ah VRLA batteries.

     222,000.00 250,000.00
    Buy now
  • C-TEC CFP AlarmSense 2 Zone Two-Wire Fire Alarm Panel

    • Third-party certified to EN54 parts 2 and 4 by the Loss Prevention Certification Board (LPCB).

    • Intuitive user-friendly interface with colour-coded buttons and combined keypad/keyswitch entry.

    • Manufactured by C-TEC in the UK.

    • Two AlarmSense zone circuits – compatible with Apollo’s AlarmSense detectors, call points, sounders and visual indicators.

    • Four conventional sounder circuits.

    • Integral 1.5A EN54-4/A2 compliant switch mode PSU.

    • Wide range of engineering functions including zone test, coincidence, zone delay and non-latching zones.

    • Two on-board relays (Fire and Fault).

    • Two open-collector outputs (Remote and Reset).

    • ‘Class change’ and alert inputs.

    • Installer-friendly design.

    • Attractive flush or surface mountable plastic lid and enclosure – no bezel required.

    • Low 25mA quiescent current.

    • Multiple indicators.

    • System expansion connections provided for up to eight two-wire repeaters (one CFP761 network card required per system).

    • Space for two x 12V 3.3Ah VRLA batteries.

     195,000.00 200,000.00
    Buy now
Select your currency
NGN Nigerian naira
Shopping cart0
There are no products in the cart!
Continue shopping
0

Cart

Your Cart is Empty

Back To Shop

Shop By Departments

Cart

No products in the cart.

Filter Products