Products between 1kg-2kg
-
C-TEC CFP 8 Zone Repeater Panel Part No. CFP760
-
-
Can be used to repeat the functions of a master CFP standard or AlarmSense 2-8 zone fire panel at remote parts of site (e.g. all potential fire service entrances).
-
Up to 8 repeaters per CFP master.
-
Includes its own Mains power supply that requires its own standby battery supply.
-
Provides the user with access to all AL1 and AL2 functions.
-
Master/Repeater communication achieved using CFP761 network driver cards (one CFP761 is supplied with the Repeater, an additional CF761 card is required at the master CFP).
-
Communicates over screened two-wire fire resistant cable.
-
Total repeater network cable length should not exceed 1KM.
-
Attractive flush or surface mountable plastic lid and enclosure – no bezel required.
-
₦ 295,000.00₦ 300,000.00Buy nowC-TEC CFP 8 Zone Repeater Panel Part No. CFP760
₦ 295,000.00₦ 300,000.00 -
-
C-TEC EP203 Automatic Extinguisher Panel Part No. EP203
-
Technical Specifications
-
Approvals/certifications Certified to EN12094-1 and EN54-2 & 4 by the LPCB.
-
Mains supply 230V 50/60Hz.
-
Mains rated current 810mA max.
-
Internal power supply 19V-28.5V (27V nominal). Ripple 7V maximum (battery fault).
-
Total output current limited to 1.5A @ 230Vac continuous, 3A peak (ImaxA eq 800mA).
-
Quiescent current 40mA (on mains fail). Zone quiescent 2mA max.
-
Max battery size and type 2 x 12V 7Ah VRLA connected in series.
-
No. of detector zone circuits 3 @ 19-28Vdc (Max. length per circuit is 250m).
-
Max. devices per detector zone 20 detectors (or 32 detectors/manual call points combined).
-
No. of conventional sounder circuits 3 (two x 1st stage; one x 2nd stage). Max. length per circuit is 50m).
-
EOL resistor value 6800 5% Tol. 0/25W (blue, grey, red, gold).
-
Max. sounder output current 3 x 200mA.
-
Auxiliary relays Six: (1) Fire; (2) Local Fire; (3) Extract Fan; (4) 1st Stage; (5) 2nd Stage; (6) Fault. Volt free single pole
changeover. Max. switch current 1A; Max. switch voltage 30Vdc. Five additional relays available via
EP212 relay card.
Other outputs Extinguishant release (21-28Vdc, rated at 1A for 5 mins). Programmable to delay by 0-60 seconds; to
be active for 1-300 seconds and to flood for 60-1800 seconds.
Auxiliary inputs Six: (1) Manual Release; (2) Flow Switch; (3) Low Pressure; (4) Mode; (5) Hold; (6) Abort. 8K-2K normal;
1.8K-200 active; 150-0 short circuit. EOL value: 6K8 +/-5%, 0.25W.
Indicators Multiple indicators are provided – refer to the EP203 instructions for details.
Controls Extinguishant release (housed in yellow casing); Accessed keyswitch; Operation keyswitch (Manual
only or Manual & Auto); Buttons for Menu; Silence internal sounder; reset panel; silence/resound
sounders and scrolling.
Expansion connections Yes – for up to 8 x Remote status units (2 wire RS485 + 2 wire power) and/or up to 8 x Ecomomy
status units (2 wire power + 2 wire mode select).
Product dimensions (mm) 439 W x 276 H x 70 D mm (back box); 467 W x 293 H x 29 D mm (lid).
Construction & finish Metal back box; metal chassis’ plastic lid.
IP Rating IP30.
Weight 4.2kg (without batteries).
Operating conditions/temperature -5°C to +40°C. Max relative humidity: 95%
₦ 570,000.00₦ 600,000.00Buy nowC-TEC EP203 Automatic Extinguisher Panel Part No. EP203
₦ 570,000.00₦ 600,000.00 -
-
C-TEC Remote Status Unit, Surface Part No. EP210S
-
-
-
- DESCRIPTION
- Designed to connect to the RS485 terminals on an EP203 Automatic Extinguisher Panel to provide remote system status indication via a 128 x 64 pixel LCD status display.
- Also includes a pull-down manual release button, a mode (auto/manual) keyswitch and a wide range of system status indicators.
- Three monitored input connections (Hold, Abort and Mode).
- Max. 8 remote status units per EP203 panel.
- Surface remote status units (EP210S) and weather proof enclosures (BF359/1) also available.
-
-
-
-
C-TEC System Line Terminator Part No. EP214
-
-
-
- An optional system expansion device for use with the EP203 three zone automatic extinguisher panel.
- Ideal for terminating the EP203’s release output to a gas release solenoid or multiple metrons/igniting actuators.
- One EP214 terminator is required per solenoid.
- Max. 2 x EP214 terminators per EP203 (note one is supplied with the EP203).
- Measures just 55m W x 55mm H x 22mm D.
-
-
-
-
C-TEC Flushing Mount Remote Status Unit Part No. EP210F
-
-
-
-
Designed to connect to the RS485 terminals on an EP203 Automatic Extinguisher Panel to provide remote system status indication via a 128 x 64 pixel LCD status display.
-
Also includes a pull-down manual release button, a mode (auto/manual) keyswitch and a wide range of system status indicators.
-
Three monitored input connections (Hold, Abort and Mode).
-
Max. 8 remote status units per EP203 panel.
-
Surface remote status units (EP210S) and weather proof enclosures (BF359/1) also available.
-
-
-
₦ 300,000.00₦ 320,000.00Buy nowC-TEC Flushing Mount Remote Status Unit Part No. EP210F
₦ 300,000.00₦ 320,000.00 -
-
C-TEC Output Expansion Relay Board Part No. EP212
-
- An optional system expansion device for use with the EP203 three zone automatic extinguisher panel.
- Mounts inside the EP203Â panel to provide five volt free relay contacts (reset, mode, discharged, hold and abort).
- Reset relay switches during the panel’s reset cycle.
- Mode relay switches when the extinguishant system’s mode is changed to manual.
- Discharged relay switches when a released flow switch input (e.g. from the extinguishant pipework) is received to indicate the extinguishant has been released.
- Hold relay switches when a hold input is received at the panel. If the panel is in 2nd stage alarm (i.e. it is in automatic mode and detection circuits are activated, or it is in either automatic/manual mode and a manual release input is operated) the extinguishant release sequence is halted.
- Abort relay switches when an abort input is received at the panel to cancel the extinguishant release sequence.
-