- You cannot add that amount of "Zeta Optical Smoke Detector (Fire Alarm System)" to the cart because there is not enough stock (0 remaining).
-
-
HORING LIH AH-0621 UL Photoelectric Smoke Detector
- UL Listed.
- The standard detector is 2-wire or 3-wire with base.
- For 4-wire type just add one relay output module on 3-wire base. Simple and easy module placement enables wider application.
- Twin-color LED display enables viewer to easily identify the current status of detector.
- Contacts material is highly acid-resistant and rust-resistant.
- Detector is made of high endurance, solid and colorfast Fire-proof plastic.
- Non-loosening screws on base terminal for easy installation.
- Detector has passed strict EMC test, which greatly eliminates false alarms caused by interference from nearby sources.
-
HORING LIH AH Q05 EN Combination Smoke and Heat Detector
- EN54-7 & EN54-5 Approval.
- The standard detector is 2-wire or 3-wire with base.
- For 4-wire type just add one relay output module on 3-wire base. Simple and easy module placement enables wider application.
- Dual LEDs for 360-degree visibility. Bi-color LED, Stand-by Status: Green; Alarm Status: Red.
- Detector is made of high endurance, solid and colorfast Fire-proof plastic.
- Non-loosening screws on base terminal for easy installation.
- Detector has passed strict EMC test, which greatly eliminates false alarms caused by interference from nearby sources.
-
HORING LIH AH Q01 EN Photoelectric Smoke Detector
- EN54-7 Approval.
- The standard detector is 2-wire or 3-wire with base.
- For 4-wire type just add one relay output module on 3-wire base. Simple and easy module placement enables wider application.
- Dual LEDs for 360-degree visibility. Bi-color LED, Stand-by Status: Green; Alarm Status: Red.
- Detector is made of high endurance, solid and colorfast Fire-proof plastic.
- Non-loosening screws on base terminal for easy installation.
- Detector has passed strict EMC test, which greatly eliminates false alarms caused by interference from nearby sources.
₦ 10,000.00₦ 13,000.00Buy nowHORING LIH AH Q01 EN Photoelectric Smoke Detector
₦ 10,000.00₦ 13,000.00 -
HORING LIH NDKB1 Carbon Monoxide Detector
- Test button for alarm simulation.
- Green LED to confirm the unit is under normal operation.
- Two modes of the Alarm LED in visible and audible warning to easily identify the status.
- Three modes of the Fault LED in visible and audible warning to easily identify the causes.
- Triple-color LED display with high brightness enables viewers to easily identify the status of detector.
- A set of relay output: COM. N.O. N.C. (NDKB1)
-
PAXTON Sales Code: 682-493EX Net2 Plus 1 door controller
Single door networkable access control unitPlug into a TCP/IP network using a RJ45 plugFeatures a built in TCP/IP converterDifferent control units can be mixed on a siteFLASH memory allows easy upgradesUse Paxton or 3rd party readers -
HORING LIH AH QP412 4 zone Conventional Fire Alarm Control Panel
- Day/Night Mode Selection.
- Ground fault detection feature.
- 24V DC power output for external load.
- Zone EOL resistor can be set from panel board.
- Zone Output, Fault Output and Alarm Output (NO. NC. COM).
- System will back to normal automatically after alarm status is released.
- Removable front board for easy maintenance.
- Easy-to-clean front board is able to avoid dirt attached.
- High luminance and long life span LED.
- Independent visual & audible indication for zone open/short fault.
- Independent visual & audible indication for AC power &Â battery fault.
- Visual & audible indication for sounder short circuit fault.
- Buzzer silence with 3-mode operation feature.
- Accurate supervision circuit for battery.
-
HORING LIH AH QP212 2 zone Conventional Fire Alarm Control PanelÂ
- Day/Night Mode Selection.
- Ground fault detection feature.
- Zone Output, Fault Output and Alarm Output (NO. NC. COM).
- System will back to normal automatically after alarm status is released.
- Removable front board for easy maintenance.
- Easy-to-clean front board is able to avoid dirt attached.
- High luminance and long life span LED.
- Independent visual & audible indication for zone open/short fault.
- Independent visual & audible indication for AC power &Â battery fault.
- Visual & audible indication for sounder short circuit fault.
- Buzzer silence with 3-mode operation feature.
- Accurate supervision circuit for battery.
-
HORING LIH AH QP112 1 zone Conventional Fire Alarm Control Panel
- Removable front board for easy maintenance.
- Easy-to-clean front board is able to avoid dirt attached.
- High luminance and long life span LED.
- Independent visual & audible indication for zone open/short fault.
- Independent visual & audible indication for AC power &Â battery fault.
- Visual & audible indication for sounder short circuit fault.
- Buzzer silence with 3-mode operation feature.
- Accurate supervision circuit for battery.
- Short circuit = Alarm feature ( selected by JUMPER applicable for manual call point w/o resistance).