The conventional sounder/flasher combines a sounder and a flasher into a single, versatile unit. The conventional sounder/flasher combines the best features of two types of emergency communication. Designed for use as part of a two-wire or four-wire fire alarm system. In an emergency, the sounder announces the audible signal, while the flasher provides the visual alert signal. Combining these two features into a modern and sleek design is more effective. Saves time, and, most importantly, and makes modern fire alarm systems safer.
Conventional sounders have a high decibel output, whereas flasher are suitable for Disability Discrimination Act (DDA) compliant installations.
-
Zeta 24V 6” Fire Alarm Bell
DESCRIPTION
Zeta introduces a new 6 “ bell with a modern
construction including an aluminium gong with high db
output and a moderate current consumption.
The new ZT-BELL/6 is available in both indoor and
outdoor versions with very stylish termination box to
allow access to back box without using special tools.
This new range with its output replaces the need for 8”
bell.₦10,000.00 -
₦10,000.00
-
₦13,500.00
-
C-TEC 4 Zone Sounder Circuit Extender Kit Part No. FF502P
- Provides four extra conventional sounder circuits with open and short circuit fault monitoring.
- Compatible with most manufacturers’ fire alarm control panels.
- Supplied on a double gang plate.
- Basic connection requires four wires: 24 VDC, 0V, Sounder –Ve & Sounder +Ve.
- Sounder -Ve & Sounder +Ve can be connected at the host panel or any convenient point on a sounder circuit (DO NOT SPUR). 24 VDC and 0V can be derived from the host panel or, alternatively, from an external PSU.
- If connecting the FF502P to a C-TEC fire panel only three input control wires are required (Sounder -Ve is not required as our conventional panels have a common 0V rail).
- Fits on standard UK 25mm flush or surface mount back boxes.
-
C-TEC Conventional Sounder Isolator Controller Part No. BF365SC
- Designed to meet requirement 17.9.2c of Dutch standard NEN2575.
- BSI certified to EN54 parts 17 & 18.
- Easily interfaced to a conventional fire alarm sounder circuit.
- Allows low-cost, non-fire resistant sounder circuit cabling to be used when used in conjunction with our BF365IM Isolator Modules (subject to fire officer approval).
- Wiring must be made in a loop arrangement, beginning and ending at the controller.
- If a wiring fault should occur, the Module(s) nearest to the faulty section of cabling will, if needed, isolate this section. As the Modules are driven from each direction, any loss of cable integrity will have no effect on the functionality of the actual sounders.
- Fits on standard UK 25mm flush or surface mount back boxes
-
C-TEC Sounder Isolator Module (max. 30 per BF365SC) Part No. BF365IM
- A fault isolating module with sounder drive capability designed to meet requirement 17.9.2c of Dutch standard NEN2575.
- BSI certified to EN54 parts 17 & 18.
- Measures just 55mm x 55mm x 16mm (will fit in the base of most conventional sounders).
- Up to 30 BF365IM modules per BF365SC controller.
- Allows low-cost, non-fire resistant sounder circuit cabling to be used when used in conjunction with our BF365SC Sounder Isolator Controller (subject to fire officer approval).
- Wiring must be made in a loop arrangement, beginning and ending at the controller.
- If a wiring fault should occur, the Module(s) nearest to the faulty section of cabling will, if needed, isolate this section. As the Modules are driven from each direction, any loss of cable integrity will have no effect on the functionality of the actual sounders.
-
C-TEC 24V Polarised Fire Bell Part No. BF336
- A tough durable red fire bell.
- Widely used in schools and other establishments for signalling ‘class’ or ‘shift’ changes.
- Designed for internal use only.
- 152mm (6 inch) x 60mm
- Incorporates highly efficient rotary centrifugal movements to provide a high sound output of up 95dB.
- Low current consumption.
- Includes a multi-fixing base plate.
-
C-TEC 24V Red Polarised Fire Bell Part No. BF336C
-
-
- A robust red fire bell certified to EN54-3 by the LPCB.
- Designed for internal use only.
- 152mm (6 inch) x 56mm
- Up to 97dB sound output.
- Wide 19-27V DC operating range.
- Low current consumption.
- Includes a multi-fixing base plate.
-
-
-
C-TEC ActiV Conventional Hi-Output 100dB(A) Wall Sounder (deep base) Part No. BF430C/CC/DR
-
-
-
-
-
- Third-party certified to EN54-3 (Sounders).
- Impressive 100dB(A) sound output @ 1m.
- Includes 31 selectable primary tones and an optional secondary tone.
- Two volume levels (high and low)
- Alarm Current at 30Vdc = 5.5mA.
- Alarm Current at 18Vdc = 3.8mA.
- IP33C rated.
- Manufactured in the UK by C-TEC.
-
-
-
-
-
-
C-TEC ActiV Conventional Weatherproof Hi-Output W-2.75-9 Wall VAD c/w Voice Sounder (IP55) Part No. BF447C/CC/DR/65
-
-
-
-
- Provides ‘W-2.75-9’ rated light distribution when wall mounted (min. 0.4 lux over a 2.75 x 9m cuboid area). Can also be used as a W-4-4 VAD.
- Superb sound intelligibility.
- Choose from two evacuation voice messages and four evacuation alarm tones (your selected evacuation message will be preceded by the selected tone).
- Three selectable VAD flash rates (0.5Hz, 1Hz, OFF)
- Alarm Current at 30Vdc = 17mA (0.5Hz) or 24mA (1Hz)
- Alarm Current at 18Vdc = 18.5mA (0.5Hz) or 30mA (1Hz)
- IP55C rated (weatherproof).
- Manufactured in the UK by C-TEC.
-
-
-
-
-
C-TEC ActiV Conventional Hi-Output W-2.75-9 Wall VAD c/w Voice Sounder (deep base) Part No. BF447C/CC/DR
-
-
-
- Provides ‘W-2.75-9’ rated light distribution when wall mounted (min. 0.4 lux over a 2.75 x 9m cuboid area). Can also be used as a W-4-4 VAD.
- Superb sound intelligibility.
- Choose from two evacuation voice messages and four evacuation alarm tones (your selected evacuation message will be preceded by the selected tone).
- Three selectable VAD flash rates (0.5Hz, 1Hz, OFF)
- Alarm Current at 30Vdc = 17mA (0.5Hz) or 24mA (1Hz)
- Alarm Current at 18Vdc = 18.5mA (0.5Hz) or 30mA (1Hz)
- IP33C rated.
- Manufactured in the UK by C-TEC.
-
-
-
-
APOLLO AlarmSense Relay Module Part No. 55000-835APO
- Allows devices such as vibrating pillow alarms or vibrating radio/paging devices to be connected to an AlarmSense system.
- Can also be used to monitor and switch conventional sounders and visual indicators.
-
APOLLO AlarmSense Base Sounder Part No. 45681-510APO
- Will accept any AlarmSense fire detector to provide fire detection and an audible alarm warning signal at the same point.
- 70d-87dB(A) sound output.
- Certified to EN54-3 by UL International (UK) Limited.
- Suitable for use with C-TEC’s CFP AlarmSense range of 2-8 Zone Two-Wire Fire Panels.
- AlarmSense priority/non priority signal recognition
- Detects the removal of a detector head and reports a fault
- Continues to work during unauthorised removal of detector.
- High and low volume ranges
- Red and white caps available for stand-alone use.
- Can also be purchased as part of a detector/sounder base combination (see Combination AlarmSense Devices section below).
-
APOLLO AlarmSense Base Sounder/Visual Indicator Part No. 45681-509APO
- Will accept any AlarmSense fire detector to provide fire detection and an audible AND visual alarm warning signal at the same point.
- 70d-87dB(A) sound output (visual indicator activates with sounder).
- Certified to EN54-3 by UL International (UK) Limited.
- Suitable for use with C-TEC’s CFP AlarmSense range of 2-8 Zone Two-Wire Fire Panels.
- AlarmSense priority/non priority signal recognition
- Detects the removal of a detector head and reports a fault
- Continues to work during unauthorised removal of detector.
- High and low volume ranges.
- Red and white caps available for stand-alone use.
- Can also be purchased as part of a detector/sounder visual indicator base combination (see Combination AlarmSense Devices section below).
-
APOLLO AlarmSense Open Area Sounder/Visual Indicator
- A powerful wall-mounting open-area Sounder/Visual Indicator suitable for use with C-TEC’s CFP AlarmSense range of 2-8 Zone Two-Wire Fire Panels.
- IP65 rated.
- Up to 99dB(A) sound output at 1m.
- Ultra-bright red LED.
- Device locking facility.
- Max. five Open-Area Alarm Devices per AlarmSense zone.
-
APOLLO AlarmSense Open Area Sounder IP65
- A powerful wall-mounting open-area Sounder/Visual Indicator suitable for use with C-TEC’s CFP AlarmSense range of 2-8 Zone Two-Wire Fire Panels.
- IP65 rated.
- Up to 99dB(A) sound output at 1m.
- Ultra-bright red LED.
- Device locking facility.
- Max. five Open-Area Alarm Devices per AlarmSense zone.