The conventional sounder/flasher combines a sounder and a flasher into a single, versatile unit. The conventional sounder/flasher combines the best features of two types of emergency communication. Designed for use as part of a two-wire or four-wire fire alarm system. In an emergency, the sounder announces the audible signal, while the flasher provides the visual alert signal. Combining these two features into a modern and sleek design is more effective. Saves time, and, most importantly, and makes modern fire alarm systems safer.

Conventional sounders have a high decibel output, whereas flasher are suitable for Disability Discrimination Act (DDA) compliant installations.

Showing 1–16 of 42 results

  • AH-03127-BS Electronic Sounder and Beacon

    General This electronic sounder is designed for use with fire alarm systems, security systems and industrial signaling systems. Combined sounder and beacon provides and audio-visual warning with is suitable for places where high sound output and visual indication is required. Characteristics   EN54-3 Approval Type B Sonder Beacon 32 signal tones selectable by Dip switch. …

    AH-03127-BS Electronic Sounder and BeaconRead More

    Read more
  • APOLLO AlarmSense Base Sounder Part No. 45681-510APO

    • Will accept any AlarmSense fire detector to provide fire detection and an audible alarm warning signal at the same point.
    • 70d-87dB(A) sound output.
    • Certified to EN54-3 by UL International (UK) Limited.
    • Suitable for use with C-TEC’s CFP AlarmSense range of 2-8 Zone Two-Wire Fire Panels.
    • AlarmSense priority/non priority signal recognition
    • Detects the removal of a detector head and reports a fault
    • Continues to work during unauthorised removal of detector.
    • High and low volume ranges
    • Red and white caps available for stand-alone use.
    • Can also be purchased as part of a detector/sounder base combination (see Combination AlarmSense Devices section below).
    Read more
  • APOLLO AlarmSense Base Sounder/Visual Indicator Part No. 45681-509APO

    • Will accept any AlarmSense fire detector to provide fire detection and an audible AND visual alarm warning signal at the same point.
    • 70d-87dB(A) sound output (visual indicator activates with sounder).
    • Certified to EN54-3 by UL International (UK) Limited.
    • Suitable for use with C-TEC’s CFP AlarmSense range of 2-8 Zone Two-Wire Fire Panels.
    • AlarmSense priority/non priority signal recognition
    • Detects the removal of a detector head and reports a fault
    • Continues to work during unauthorised removal of detector.
    • High and low volume ranges.
    • Red and white caps available for stand-alone use.
    • Can also be purchased as part of a detector/sounder visual indicator base combination (see Combination AlarmSense Devices section below).
    Read more
  • APOLLO AlarmSense Open Area Sounder IP65

    • A powerful wall-mounting open-area Sounder/Visual Indicator suitable for use with C-TEC’s CFP AlarmSense range of 2-8 Zone Two-Wire Fire Panels.
    • IP65 rated.
    • Up to 99dB(A) sound output at 1m.
    • Ultra-bright red LED.
    • Device locking facility.
    • Max. five Open-Area Alarm Devices per AlarmSense zone.
    Read more
  • APOLLO AlarmSense Open Area Sounder/Visual Indicator

    • A powerful wall-mounting open-area Sounder/Visual Indicator suitable for use with C-TEC’s CFP AlarmSense range of 2-8 Zone Two-Wire Fire Panels.
    • IP65 rated.
    • Up to 99dB(A) sound output at 1m.
    • Ultra-bright red LED.
    • Device locking facility.
    • Max. five Open-Area Alarm Devices per AlarmSense zone.
    Read more
  • APOLLO AlarmSense Relay Module Part No. 55000-835APO

    • Allows devices such as vibrating pillow alarms or vibrating radio/paging devices to be connected to an AlarmSense system.
    • Can also be used to monitor and switch conventional sounders and visual indicators.
    Read more
  • C-TEC 24V Polarised Fire Bell Part No. BF336

    • A tough durable red fire bell.
    • Widely used in schools and other establishments for signalling ‘class’ or ‘shift’ changes.
    • Designed for internal use only.
    • 152mm (6 inch) x 60mm
    • Incorporates highly efficient rotary centrifugal movements to provide a high sound output of up 95dB.
    • Low current consumption.
    • Includes a multi-fixing base plate.
    Read more
  • C-TEC 24V Red Polarised Fire Bell Part No. BF336C

        • A robust red fire bell certified to EN54-3 by the LPCB.
        • Designed for internal use only.
        • 152mm (6 inch) x 56mm
        • Up to 97dB sound output.
        • Wide 19-27V DC operating range.
        • Low current consumption.
        • Includes a multi-fixing base plate.
    Read more
  • C-TEC 4 Zone Sounder Circuit Extender Kit Part No. FF502P

    Download datasheet

    Read more
  • C-TEC ActiV Conventional Hi-Output 100dB(A) Wall Sounder (deep base) Part No. BF430C/CC/DR

    Read more
  • C-TEC ActiV Conventional Hi-Output W-2.75-9 Wall VAD c/w Voice Sounder (deep base) Part No. BF447C/CC/DR

    Read more
  • C-TEC ActiV Conventional Weatherproof Hi-Output W-2.75-9 Wall VAD c/w Voice Sounder (IP55) Part No. BF447C/CC/DR/65

    Read more
  • C-TEC Conventional Sounder Isolator Controller Part No. BF365SC

    • Designed to meet requirement 17.9.2c of Dutch standard NEN2575.
    • BSI certified to EN54 parts 17 & 18.
    • Easily interfaced to a conventional fire alarm sounder circuit.
    • Allows low-cost, non-fire resistant sounder circuit cabling to be used when used in conjunction with our BF365IM Isolator Modules (subject to fire officer approval).
    • Wiring must be made in a loop arrangement, beginning and ending at the controller.
    • If a wiring fault should occur, the Module(s) nearest to the faulty section of cabling will, if needed, isolate this section. As the Modules are driven from each direction, any loss of cable integrity will have no effect on the functionality of the actual sounders.
    • Fits on standard UK 25mm flush or surface mount back boxes
    Read more
  • C-TEC Sounder Isolator Module (max. 30 per BF365SC) Part No. BF365IM

    • A fault isolating module with sounder drive capability designed to meet requirement 17.9.2c of Dutch standard NEN2575.
    • BSI certified to EN54 parts 17 & 18.
    • Measures just 55mm x 55mm x 16mm (will fit in the base of most conventional sounders).
    • Up to 30 BF365IM modules per BF365SC controller.
    • Allows low-cost, non-fire resistant sounder circuit cabling to be used when used in conjunction with our BF365SC Sounder Isolator Controller (subject to fire officer approval).
    • Wiring must be made in a loop arrangement, beginning and ending at the controller.
    • If a wiring fault should occur, the Module(s) nearest to the faulty section of cabling will, if needed, isolate this section. As the Modules are driven from each direction, any loss of cable integrity will have no effect on the functionality of the actual sounders.
    Read more
  • Gent 74430-88NM 6 inch Fire Red Ball Sounder 24v Dc

    67,000.00
    • Designed with a modern feel
    • Has a loud ring output
    • There’s an option of a weatherproof kit
    • All parts clip together to assemble
    Add to cart
  • Gent C3-SN-R Electronic 2way Sounder Red

    12,000.00

    Low profile GENT sounder, ideal for use in environments where aesthetics should be discrete as possible. The GENT S3-SN-R Electronic 2 way Sounder Red is rated at 100 dBA but can be remotely configured using the HandiLink IR remote control to turn on individual sounders when in commissioning mode and to adjust the volume. Access is no …

    Gent C3-SN-R Electronic 2way Sounder RedRead More

    Add to cart

Cart

Your Cart is Empty

Back To Shop