Conventional Fire Alarm System employs one or more initiating circuits linked to sensors wired in parallel. The number of such circuits used limits the information density. Best utilized for smaller applications, a conventional fire alarm remains a viable fire protection solution.
Conventional fire alarm system use zones. Multiple devices, both initiating and notification devices, make up a zone that connects to the main control panel. Conventional systems are analog in that they use electrical currents to communicate with the control panel.
Conventional system relies on individual circuits to communicate with the control panel. The panel’s ability to receive information limited by the number of devices it can support.
-
ZETA ZT-CP4/F Zeta CP4 Conventional Flush Mount Manual Call Point, White
The ZT-CP3 call point is compatible with most conventional fire alarm systems. It is safe for use in areas where glass cannot be used, e.g. food processing plants and swimming/leisure centres.
₦ 9,500.00Buy now -
ZETA ZP-CP4/G | CP4 Conventional Surface Mount Manual Call Point, Green
Technical Specification
- Current Rating: 3 Amps 12 – 24V DC
- Low Current Rating: 1-100 mA
- Housing and Mounting Box Material: Polycarbonate
- Electrical Contact Material: Silver plated brass
- Operating Temperature: -20 degrees C to +65 degrees C
- Installation Terminal Conductor: Size 0.5mm – 2.5mm
- Colour: Red
- Mounting: Surfacce (with supplied back box) or Flush (optional flush mount bezel CP3-FMB required)
- IP Rating: IP32
-
ZETA ZP-CP4/B | CP4 Conventional Surface Mount Manual Call Point, Blue
Technical Specification
-
Current Rating: 3 Amps 12 – 24V DC
-
Low Current Rating: 1-100 mA
-
Housing and Mounting Box Material: Polycarbonate
-
Electrical Contact Material: Silver plated brass
-
Operating Temperature: -20 degrees C to +65 degrees C
-
Installation Terminal Conductor: Size 0.5mm – 2.5mm
-
Colour: Red
-
Mounting: Surfacce (with supplied back box) or Flush (optional flush mount bezel CP3-FMB required)
-
IP Rating: IP32
₦ 63,000.00₦ 65,000.00Buy nowZETA ZP-CP4/B | CP4 Conventional Surface Mount Manual Call Point, Blue
₦ 63,000.00₦ 65,000.00 -
-
ZETA ZP-CP4/W | CP4 Conventional Surface Mount Manual Call Point, White
Technical Specification
- Current Rating: 3 Amps 12 – 24V DC
- Low Current Rating: 1-100 mA
- Housing and Mounting Box Material: Polycarbonate
- Electrical Contact Material: Silver plated brass
- Operating Temperature: -20 degrees C to +65 degrees C
- Installation Terminal Conductor: Size 0.5mm – 2.5mm
- Colour: Red
- Mounting: Surfacce (with supplied back box) or Flush (optional flush mount bezel CP3-FMB required)
- IP Rating: IP32
-
ZETA ZP-CP4 | CP4 Conventional Surface Mount Manual Call Point, Red
Technical Specification
- Current Rating: 3 Amps 12 – 24V DC
- Low Current Rating: 1-100 mA
- Housing and Mounting Box Material: Polycarbonate
- Electrical Contact Material: Silver plated brass
- Operating Temperature: -20 degrees C to +65 degrees C
- Installation Terminal Conductor: Size 0.5mm – 2.5mm
- Colour: Red
- Mounting: Surfacce (with supplied back box) or Flush (optional flush mount bezel CP3-FMB required)
- IP Rating: IP32
-
ZETA CP3-FMB/R | Abort Call Point Flush Mount Bezel
The Zeta CP3-FMB is a flush mounting bezel for the ID2 & CP3 manual call points.
-
ZETA CP3-FMB/W | Abort Call Point Flush Mount Bezel
The ZT-CP3 and ZT-CP3/WP call points are unique in that they mimic the feel of breaking glass whilst offering the user the benefits and environmental advantages of a re-settable operating element.
-
ZETA ZT-CP3 | Weatherproof Manual Release Unit (Surface Mount)
The ZT-CP3 and ZT-CP3/WP call points are unique in that they mimic the feel of breaking glass whilst offering the user the benefits and environmental advantages of a re-settable operating element
-
Zeta Magnetic Door Holder Floor Bracket (ZT-BR)
An optional bracket for floor or wall mounting the Zeta ZT-DR24 & ZT-DR240.
-
Zeta Magnetic Door Holder 240V
-
Technical Specification
- Model: ZT-DR24 / ZT-DR240
- Rated Voltage: 24V DC or 240VAC
- Rated Current: 35mA
- Switch Through AUX: Yes (with Diode)
- Needs Back EMF Diode: Yes
- Holding Force: 200 Newton
- Dimensions (Main Unit Only) (W x H x D mm): 110 x 85 x 38
- Dimensions (Keeper Plate) (W x H x D mm): 55 x 55 x 50
- Fixing Centres: 50 mm
- Weight: 404g
-
-
Zeta Fire Alarm Duct Unit c/w 230V Relay Board (ZT-DU/230)
- Fire and Fault relays
- Option for latching or non-latching
- Manual reset (latching option)
₦ 250,000.00Buy now