Conventional Fire Alarm System employs one or more initiating circuits linked to sensors wired in parallel. The number of such circuits used limits the information density. Best utilized for smaller applications, a conventional fire alarm remains a viable fire protection solution.
Conventional fire alarm system use zones. Multiple devices, both initiating and notification devices, make up a zone that connects to the main control panel. Conventional systems are analog in that they use electrical currents to communicate with the control panel.
Conventional system relies on individual circuits to communicate with the control panel. The panel’s ability to receive information limited by the number of devices it can support.
- You cannot add that amount of "Zeta Raptor Addressable Weatherproof Sounder Beacon (Red Plastic, White Flash)" to the cart because there is not enough stock (0 remaining).
-
Zeta Raptor Addressable Weatherproof Sounder Beacon (Red Plastic, White Flash)
🛡️ Key Advantages & Functions:
-
Addressable System Compatibility: Integrates seamlessly into addressable fire alarm systems.
-
Weatherproof Design (IP65 Rated): Built to withstand rain, dust, and outdoor elements.
-
High Volume Sounder: Emits a powerful audio alert up to 100dB for immediate attention.
-
Bright White LED Flash: Ensures visibility in smoke, fog, and low-light conditions.
-
Durable Red Plastic Housing: Tough, high-visibility design for quick identification.
-
Low Current Consumption: Efficient and cost-effective operation.
-
Multiple Tone & Volume Settings: Customizable to suit your site’s safety needs.
Whether it’s a fire, gas leak, or emergency evacuation, the Zeta Raptor Weatherproof Sounder Beacon delivers unmatched performance when it matters most.
🛒 Get yours today at Trends Ventures Limited – your trusted safety partner.
₦ 133,350.00₦ 135,000.00Buy nowZeta Raptor Addressable Weatherproof Sounder Beacon (Red Plastic, White Flash)
₦ 133,350.00₦ 135,000.00 -
-
₦ 120,000.00
₦ 125,000.00Buy nowC-Tec FP 8 Zone Conventional Fire Alarm Panel-Ff388-2
₦ 120,000.00₦ 125,000.00 -
Gent CWST-RW-W5 VAD Red Base – White Flash & IP65 Base
Gent CWST-RW-W5 VAD Red Base – White Flash & IP65 Base
CWST-RW-W5 features high output LEDs, advanced optics and an innovative lens design, providing outstanding Omni-directional light coverage at low current draw. Specifically designed for, and approved to meet EN54-23. The CWST-RW-W5 delivers outstanding quality, reliability and long operational life. Weatherproof base provides IP65 for external use applications.
-
Gent 14115-KEY Spare Bulgin Key – Pack of 10
Gent 14115-KEY Spare Bulgin Key – Pack of 10
A spare Bulgin Key for 14115-08 key operated (pack of 10).
For use with Bulgin Key Switches (SM0319, SM0320, SM0324) and Gent key operated call points.
Bulgin keyswitches were used on the following older Gent Fire Alarm Panels for enable/disable functions:
- Fire Alarm Model 3225
- Fire Alarm Model 3226
- Fire Alarm Model 3228
- Fire Alarm Model 3280
-
System Sensor Standard Detector Base (ECO1000B)
System Sensor ECO1000B Base is designed for use with System Sensor’s ECO1000 range of conventional detectors.
₦ 2,500.00₦ 3,500.00Buy nowSystem Sensor Standard Detector Base (ECO1000B)
₦ 2,500.00₦ 3,500.00 -
Combination Optical / Thermal Smoke Sensor (58 °C) (ECO1002-A)
Features- Low profile design
- Low current draw
- Automatic drift compensation
- Operates on 12 and 24VDC Systems
- Remote alarm test feature
- Easy maintenance
- Remote LED Option
- Approved to EN54-7:2000 (Amendment 1)
- EN54-5:2000 (Amendment 1) Class A1R; CEA 4021
- Extended warranty
-
GENT Combination Rate-of-Rise / Thermal (58 °C) Smoke Sensor(ECO1005-A)
Features- Low profile design
- Low current draw
- Automatic drift compensation
- Operates on 12 and 24VDC Systems
- Remote alarm test feature
- Easy maintenance
- Remote LED Option
- Approved to EN54-7:2000 (Amendment 1)
- EN54-5:2000 (Amendment 1) Class A1R; CEA 4021
- Extended warranty
-
Optical Smoke Sensor (ECO1003-A) C/W BASE
Features- Low profile design
- Low current draw
- Automatic drift compensation
- Operates on 12 and 24VDC Systems
- Remote alarm test feature l Easy maintenance
- Remote LED Option
- Approved to EN54-7:2000 (Amendment 1)
- EN54-5:2000 (Amendment 1) Class A1R; CEA 4021
- Extended warranty
₦ 13,500.00₦ 16,000.00Buy nowOptical Smoke Sensor (ECO1003-A) C/W BASE
₦ 13,500.00₦ 16,000.00 -
Gent S4-34741 Beam Sensor Transmitter
Gent S4-34741 Beam Sensor Transmitter
The S4-34741 from Gent is a Beam Sensor Emitter.
Vigilon’s loop-powered technology allows up to 16 beam pairs to be connected to the same loop circuit, each covering a distance of up to 100m without the need for an external Power Supply Unit, wiring, or interfacing.
₦ 270,000.00₦ 300,000.00Buy nowGent S4-34741 Beam Sensor Transmitter
₦ 270,000.00₦ 300,000.00 -
Gent S4-34760-99 S-Quad Duct Mounting Bracket
Gent S4-34760-99 S-Quad Duct Mounting Bracket The S4-34760-99 is a Mounting Bracket designed for the S-Quad Duct Smoke Sensor.
₦ 196,500.00₦ 200,000.00Buy nowGent S4-34760-99 S-Quad Duct Mounting Bracket
₦ 196,500.00₦ 200,000.00 -
Gent S4-34760-15 1.5m Venturi Tube
Gent S4-34760-15 1.5m Venturi Tube
The S4-34760-15 is a Venturi Tube designed for use with Duct Smoke Sensors.
₦ 190,000.00₦ 195,000.00Buy nowGent S4-34760-15 1.5m Venturi Tube
₦ 190,000.00₦ 195,000.00