Welcome to Top Store

Cart

Your Cart is Empty

Back To Shop

Category: Conventional Fire Alarm System

Showing 97–112 of 270 results

  • C-TEC STI Call Point Stopper, Flush Mount Part No. STI-6930

    • Protective cover for flush mounted manual call points.
    • Helps prevent accidental or malicious call point activation.
    • Comprises a clear, tamper proof call point cover c/w red header labelled ‘IN CASE OF FIRE LIFT COVER – BREAK GLASS’.
    • Surface version (ST-6931) and green versions also available (see variants tab below).
    • Main picture shows Call Point Stopper with a Manual Call Point. The call point is NOT supplied.

    Download datasheet

    Read more
  • C-TEC STI Euro Call Point Stopper, Flush Mount Multi Kit with Sounder Part No. STI-15020ML

      • Protective cover for flush mounted manual call points.
      • Helps prevent malicious activation by emitting a piercing 96dB alarm tone when its hinged cover is lifted.
      • Comprises a clear, tamper proof cover and frame that retrofits over all known break glass call points.
      • Ideal for schools, colleges, hospitals and other areas where there is a threat of false activation.
      • Kit includes one Euro Stopper frame, two coloured housing shells (red & green), one break seal and two label sheets in 13 languages.
      • Surface and non-sounder variants also available (see variants tab below).
      • Main picture shows Euro Stopper with a Manual Call Point. The call point is NOT supplied.
    Read more
  • C-TEC STI Universal Call Point Stopper, Flush Mount with Sounder Part No. STI-13020FR

    • IP56 rated protective cover for flush mounted manual call points.
    • Suitable for indoor and outdoor use.
    • Helps prevent malicious activation by emitting a piercing 96dB alarm tone when its hinged cover is lifted.
    • Comprises a clear, tamper proof cover and frame that retrofits over all known break glass call points.
    • Ideal for schools, colleges, hospitals and other areas where there is a threat of false activation.
    • Kit includes one Universal Stopper frame, a red header labelled ‘IN CASE OF FIRE – LIFT BREAK GLASS’ and one break seal.
    • Surface and non-sounder variants also available (see variants tab below).
    • Main picture shows Universal Stopper with a Manual Call Point. The call point is NOT supplied.

    Download datasheet

    Read more
  • C-TEC System Line Terminator Part No. EP214

          • An optional system expansion device for use with the EP203 three zone automatic extinguisher panel.
          • Ideal for terminating the EP203’s release output to a gas release solenoid or multiple metrons/igniting actuators.
          • One EP214 terminator is required per solenoid.
          • Max. 2 x EP214 terminators per EP203 (note one is supplied with the EP203).
          • Measures just 55m W x 55mm H x 22mm D.
    Read more
  • C-TEC Yellow Extinguishant Release Call Point, Surface Part No. BF372

    Read more
  • Combination Optical / Thermal Smoke Sensor (58 °C) (ECO1002-A)

    Features
    • Low profile design
    • Low current draw
    • Automatic drift compensation
    • Operates on 12 and 24VDC Systems
    • Remote alarm test feature
    • Easy maintenance
    • Remote LED Option
    • Approved to EN54-7:2000 (Amendment 1)
    • EN54-5:2000 (Amendment 1) Class A1R; CEA 4021
    • Extended warranty
    Read more
  • EI 100B BATTERY OPERATED SMOKE

    Features
    • Warning signal when battery needs replacing
    • 9 V battery included
    • Test button for easy checking
    • Loud 85dB alarm
    Read more
  • Fire Alarm Control Panel Mains Keyswitch Part No. BF319

    • A high-quality lockable double pole Fire Alarm Control Panel Mains Keyswitch.
    • Allows the Mains supply to a fire alarm panel to be switched on or off in accordance with BS 5839-1.
    • Ideal for use during routine test and maintenance (e.g. battery test, main board replacement etc). Note, if working on the Mains in the panel you must also follow correct practice and isolate the Mains supply at the distribution board.
    • Fits on a standard UK 47mm flush or surface mount back box.
    • Supplied with 2 x M3.5 25mm fixing screws.
    • BS EN60669-1 compliant.
    • Always read the full installation and operating instructions supplied with the unit before use.
    Read more
  • FS24X-911-23-6: QuadBandâ„¢ IR3+ Detector (Aluminum)

    FS24X provides wideband Multi-Spectrum Triple IR (IR/IR/IR/Visible) flame detection. It is part of our FSX family of
    advanced technology Electro-Optical fire detectors. Using our patented* WideBand IRâ„¢, WideBand 4.3 micron IRâ„¢, and
    Visible detection technology, the FS24X sets the standard for flame detection. Sophisticated software algorithms and dual
    microprocessors ensure that the FS24X has the highest fire detection performance combined with optimal false alarm
    rejection.
    The WideBand IRâ„¢ Infrared technology using high-speed solid-state Quantum sensors allows detection of all types of fires,
    hydrocarbon and non-hydrocarbon, in all weather conditions.

    Read more
  • Gent 07011-40 Optical Beam Detector – 50 to 100 Metres Range

    350,000.00

    Manufacturer : Gent by Honeywell Part Number : 07011-40 Optical Beam Detector Set 50 to 100 Metres Range The Gent 07011-40 is an optical type beam detector set ideal for use in large open spaces.

    Add to cart
  • Gent 07011-40 Optical Beam Reflective 50-100m

    350,000.00

    – Combined transmitter and receiver unit in one discrete unit
    – Range 50-100 Metres
    – Low current consumption
    – Automatic self check drift compensation
    – Selectable sensitivity/threshold levels
    – Selectable latching / non latching fire alarm
    – LED indicators to aid the alignment process
    – Optional Low Level Test Unit for UL models only

    Add to cart
  • Gent 14115-KEY Spare Bulgin Key – Pack of 10

    Gent 14115-KEY Spare Bulgin Key – Pack of 10

    A spare Bulgin Key for 14115-08 key operated (pack of 10).

    For use with Bulgin Key Switches (SM0319, SM0320, SM0324) and Gent key operated call points.

    Bulgin keyswitches were used on the following older Gent Fire Alarm Panels for enable/disable functions:

    • Fire Alarm Model 3225
    • Fire Alarm Model 3226
    • Fire Alarm Model 3228
    • Fire Alarm Model 3280
    Read more
  • Gent 17800-02 Detector Base Without Diode – Flush Cabling

    1,500.00

    Manufacturer : Gent by Honeywell Part Number : 17800-02 Conventional Detector Base Low Profile Designed for Flush Cabling Without Head Removal Monitoring Diode For Use With The Gent 7800 Series Range of Detectors

    Add to cart
  • Gent 17801-01 Base without diode for Surface cable

    1,500.00

    The Gent 17800-01 Detector Base is designed for use with the Gent 7800 Series of conventional fire alarm detectors. The Gent 17800-01 Detector Base is designed for surface cabling. The Gent 17800-01 Detector Base does not have a head removal diode

    Add to cart
  • Gent 17801-01 Surface Mount Base with Dual Diodes

    • Key Features
      • Common to all Gent series detectors
      • Automatic locking option
      • Head out continuity monitoring
      • Easy to install
    Read more
  • Gent 17840-01 Optical Smoke Detector

    9,000.00
    • Low profile design
    • Low current draw
    • Remote alarm test feature
    • Easy maintenance
    • Remote LED option
    • Designed to comply with EN54 Pt5:2000
    Add to cart

Cart

Your Cart is Empty

Back To Shop