Category
- Uncategorized
- Access Control and Time Attendance System
- Accessories
- Addressable base
- Audio
- Cable
- Call Point
- Cameras
- Closed Circuit Television System (CCTV)
- Computer & Laptop
- Door controller
- Fire Alarm System
- Home Appliances
- Manual Callpoints
- Metal Detector
- Naso mask
- New Arrival
- Night Vision
- On Sale
- Security Alarm System
Popular
-
C-Tec FP 8 Zone Conventional Fire Alarm Panel-Ff388-2
₦125,000.00₦120,000.00 -
SOCA SL-130 Dead Bolt Lock ( All purpose type )
₦15,000.00₦13,000.00 -
SOCA SL-100D Dead Bolt Lock ( for automatic door)
₦18,000.00₦15,000.00 - SOCA SL 100A Dead Bolt ₦15,000.00
- Soca SD-30 Armored Door Loop
Tag Clouds
240V
409-711SC-EX
746-003-EX
07011-40
17801-01
55000-390APO
74430-88NM
74432-88NM
781814
accesories
AHMB-L
apple
BF319
BF430C/CC/DR
BF430C/CC/SR
C3IP-SN-R
CFP760
COMPACT-LPC-EN
CompactLPCEN
CWSO-RR-W1
CWSORRW1
ECO1003-A
FEUV2000
FF388-2
home
MZ 6100
NANO-24
NET2 PLUS 1 DOOR CONTROLLER
PD 6500i
S3EP-V-VAD-HPR-R
S3EPVVADHPRR
S4-711
S4-720
S4-720-V-VAD-HPR
S4-34410
S4-34760
ST-226EA
VIG-MCC-V3+
VS-KEY
VSINTM-PCB-UPG
XENS-807
ZS2-CSB/T
ZT-500EX
ZT-CP3
ZT-CP3/WP
Category: Fire Alarm System
Showing 65–80 of 564 results
-
C-TEC 24V BS 5446-3 Vibrating Pillow Pad Part No. BF320
Read more- Can be used in conjunction with a BF320JP connection plate to warn the hearing impaired of a potential fire alarm or evacuation alert condition.
- Vibrates and pulses on and off when triggered as per the requirements of BS 5446-3 (2015).
- Designed to be placed under a pillow to supplement the audible and/or visual indication alerts provided by a system’s sounders and/or VADs.
- Wide 10-30V DC voltage range means it can also be connected to many third-party connector plates (subject to testing).
- Includes a 2m connection lead with a locking mini-XLR connector to prevent accidental removal.
- Includes a 6K8 end-of-line monitoring resistor for fire alarm system use – see instructions for monitoring options on other systems.
-
C-TEC 24V Polarised Fire Bell Part No. BF336
Read more- A tough durable red fire bell.
- Widely used in schools and other establishments for signalling ‘class’ or ‘shift’ changes.
- Designed for internal use only.
- 152mm (6 inch) x 60mm
- Incorporates highly efficient rotary centrifugal movements to provide a high sound output of up 95dB.
- Low current consumption.
- Includes a multi-fixing base plate.
-
C-TEC 24V Red Polarised Fire Bell Part No. BF336C
Read more-
-
- A robust red fire bell certified to EN54-3 by the LPCB.
- Designed for internal use only.
- 152mm (6 inch) x 56mm
- Up to 97dB sound output.
- Wide 19-27V DC operating range.
- Low current consumption.
- Includes a multi-fixing base plate.
-
-
-
C-TEC 4 Zone Sounder Circuit Extender Kit Part No. FF502P
Read more- Provides four extra conventional sounder circuits with open and short circuit fault monitoring.
- Compatible with most manufacturers’ fire alarm control panels.
- Supplied on a double gang plate.
- Basic connection requires four wires: 24 VDC, 0V, Sounder –Ve & Sounder +Ve.
- Sounder -Ve &Â Sounder +Ve can be connected at the host panel or any convenient point on a sounder circuit (DO NOT SPUR). 24 VDC and 0V can be derived from the host panel or, alternatively, from an external PSU.
- If connecting the FF502P to a C-TEC fire panel only three input control wires are required (Sounder -Ve is not required as our conventional panels have a common 0V rail).
- Fits on standard UK 25mm flush or surface mount back boxes.
-
C-TEC ActiV 96dB(A) Conventional Base Sounder Part No. BF431C/CC/W
Read more-
- Third-party certified to EN54-3 (Sounders).
- Impressive 96dB(A) sound output @ 1m.
- Includes 31 selectable primary tones and an optional secondary tone.
- Two volume levels (high and low)
- Alarm Current at 30Vdc = 5.5mA
- Alarm Current at 18Vdc = 3.8mA
- Optional BF330CTLIDW white or BF330CTLIDR red cap available for stand-alone use.
- Supplied with a BF431QCP quick connect plate and detector spur wires.
- IP21C rated.
-
-
C-TEC ActiV Conventional ‘C Class’ Base VAD c/w Voice Sounder Part No. BF457C/CC/W
Read more-
-
-
- Superb sound intelligibility.
- Choose from two evacuation voice messages and four evacuation alarm tones (your selected evacuation message will be preceded by the selected tone).
- Provides ‘O-R-3-2.5-17’ light distribution using the same lenses and electronics as our EN54-3 & 23 certified base sounder VAD.
- Three selectable VAD flash rates (0.5Hz, 1Hz, OFF)
- Alarm Current at 30Vdc =Â 17mA (0.5Hz) or 24mA (1Hz)
- Alarm Current at 18Vdc =Â 18.5mA (0.5Hz) or 30mA (1Hz)
- Optional BF330CTLIDW white or BF330CTLIDR red cap available for stand-alone use.
- Supplied with a BF431QCP quick connect plate and detector spur wires.
- IP21C rated.
-
-
-
-
C-TEC ActiV Conventional ‘O Class’ Base VAD c/w Voice Sounder Part No. BF455C/CC/W
Read more-
-
-
- Superb sound intelligibility.
- Choose from two evacuation voice messages and four evacuation alarm tones (your selected evacuation message will be preceded by the selected tone).
- Provides ‘O-R-3-2.5-17’ light distribution using the same lenses and electronics as our EN54-3 & 23 certified base sounder VAD.
- Three selectable VAD flash rates (0.5Hz, 1Hz, OFF)
- Alarm Current at 30Vdc =Â 17mA (0.5Hz) or 24mA (1Hz)
- Alarm Current at 18Vdc =Â 18.5mA (0.5Hz) or 30mA (1Hz)
- Optional BF330CTLIDW white or BF330CTLIDR red cap available for stand-alone use.
- Supplied with a BF431QCP quick connect plate and detector spur wires.
- IP21C rated.
-
-
-
-
C-TEC ActiV Conventional Base Voice Sounder Part No. BF454C/CC/W
Read more-
-
- Superb sound intelligibility.
- Choose from two evacuation voice messages and four evacuation alarm tones (your selected evacuation message will be preceded by the selected tone).
- Alarm Current at 30Vdc = 10mA.
- Alarm Current at 18Vdc = 8mA.
- Optional BF330CTLIDW white or BF330CTLIDR red cap available for stand-alone use.
- Supplied with a BF431QCP quick connect plate and detector spur wires.
- IP21C rated.
-
-
-
C-TEC ActiV Conventional C-3-8.5 Base VAD c/w 96dB(A) Sounder Part No. BF456C/CC/W
Read more-
-
- Third-party certified to EN54-3 (Sounders) and EN54-23 (VADs).
- Provides ‘O-R-3-2.5-17’ light distribution.
- Ideally suited for use in corridors and other rectangular areas.
- Impressive 96dB(A) sound output @ 1m.
- Includes 31 selectable primary tones and an optional secondary tone.
- Two volume levels (high and low)
- Three selectable VAD flash rates (0.5Hz, 1Hz, OFF)
- Alarm Current at 30Vdc =Â 12.2mA (0.5Hz) or 19.5mA (1Hz)
- Alarm Current at 18Vdc =Â 14.5mA (0.5Hz) or 25mA (1Hz)
- Optional BF330CTLIDW white or BF330CTLIDR red cap available for stand-alone use.
- Supplied with a BF431QCP quick connect plate and detector spur wires.
- IP21C rated.
-
-
-
C-TEC ActiV Conventional Hi-Output 100dB(A) Wall Sounder (deep base) Part No. BF430C/CC/DR
Read more-
-
-
-
-
- Third-party certified to EN54-3 (Sounders).
- Impressive 100dB(A) sound output @ 1m.
- Includes 31 selectable primary tones and an optional secondary tone.
- Two volume levels (high and low)
- Alarm Current at 30Vdc = 5.5mA.
- Alarm Current at 18Vdc =Â 3.8mA.
- IP33C rated.
- Manufactured in the UK by C-TEC.
-
-
-
-
-
-
C-TEC ActiV Conventional Hi-Output 100dB(A) Wall Sounder (deep base) Part No. BF430C/CC/DR (Copy)
Read more-
-
-
-
-
- Third-party certified to EN54-3 (Sounders).
- Impressive 100dB(A) sound output @ 1m.
- Includes 31 selectable primary tones and an optional secondary tone.
- Two volume levels (high and low)
- Alarm Current at 30Vdc = 5.5mA.
- Alarm Current at 18Vdc =Â 3.8mA.
- IP33C rated.
- Manufactured in the UK by C-TEC.
-
-
-
-
-
-
C-TEC ActiV Conventional Hi-Output 100dB(A) Wall Sounder (shallow base) Part No. BF430C/CC/SR
Read more- Third-party certified to EN54-3 (Sounders).
- Impressive 100dB(A) sound output @ 1m.
- Includes 31 selectable primary tones and an optional secondary tone.
- Two volume levels (high and low)
- Alarm Current at 30Vdc = 5.5mA.
- Alarm Current at 18Vdc =Â 3.8mA.
- IP21C rated.
- Manufactured in the UK by C-TEC.
-
C-TEC ActiV Conventional Hi-Output W-2.75-9 Wall VAD c/w 100dB(A) Sounder (deep base) Part No. BF433C/CC/DR
Read more-
-
- Third-party certified to EN54-3 (Sounders) and EN54-23 (VADs).
- Provides ‘W-2.75-9’ rated light distribution when wall mounted (min. 0.4 lux over a 2.75Â x 9m cuboid area). Also rated as W-4-4 VAD.
- Impressive 100dB(A) sound output @ 1m.
- Includes 31 selectable primary tones and an optional secondary tone.
- Two volume levels (high and low)
- Three selectable VAD flash rates (0.5Hz, 1Hz, OFF)
- Alarm Current at 30Vdc =Â 12.2mA (0.5Hz) or 19.5mA (1Hz)
- Alarm Current at 18Vdc =Â 14.5mA (0.5Hz) or 25mA (1Hz)
- IP55C rated (weatherproof).
- Manufactured in the UK by C-TEC.
-
-
-
C-TEC ActiV Conventional Hi-Output W-2.75-9 Wall VAD c/w 100dB(A) Sounder (shallow base) Part No. BF433C/CC/SR
Read more- Third-party certified to EN54-3 (Sounders) and EN54-23 (VADs).
- Provides ‘W-2.75-9’ rated light distribution when wall mounted (min. 0.4 lux over a 2.75Â x 9m cuboid area). Also rated as a W-4-4 VAD.
- Impressive 100dB(A) sound output @ 1m.
- Includes 31 selectable primary tones and an optional secondary tone.
- Two volume levels (high and low)
- Three selectable VAD flash rates (0.5Hz, 1Hz, OFF)
- Alarm Current at 30Vdc =Â 12.2mA (0.5Hz) or 19.5mA (1Hz)
- Alarm Current at 18Vdc =Â 14.5mA (0.5Hz) or 25mA (1Hz)
- IP21C rated.
- Manufactured in the UK by C-TEC.
-
C-TEC ActiV Conventional Hi-Output W-2.75-9 Wall VAD c/w Voice Sounder (deep base) Part No. BF447C/CC/DR
Read more-
-
-
- Provides ‘W-2.75-9’ rated light distribution when wall mounted (min. 0.4 lux over a 2.75 x 9m cuboid area). Can also be used as a W-4-4 VAD.
- Superb sound intelligibility.
- Choose from two evacuation voice messages and four evacuation alarm tones (your selected evacuation message will be preceded by the selected tone).
- Three selectable VAD flash rates (0.5Hz, 1Hz, OFF)
- Alarm Current at 30Vdc = 17mA (0.5Hz) or 24mA (1Hz)
- Alarm Current at 18Vdc = 18.5mA (0.5Hz) or 30mA (1Hz)
- IP33C rated.
- Manufactured in the UK by C-TEC.
-
-
-
-
C-TEC ActiV Conventional O-R-3-2.5-17 Base VAD c/w 96dB(A) Sounder Part No. BF432C/CC/W
Read more-
-
-
- Third-party certified to EN54-3 (Sounders) and EN54-23 (VADs).
- Provides ‘C-3-8.5’ light distribution (min 0.4 lux over a 3 x 8.5m cylindrical area).
- Impressive 96dB(A) sound output @ 1m.
- Includes 31 selectable primary tones and an optional secondary tone.
- Two volume levels (high and low)
- Three selectable VAD flash rates (0.5Hz, 1Hz, OFF)
- Alarm Current at 30Vdc =Â 12.2mA (0.5Hz) or 19.5mA (1Hz)
- Alarm Current at 18Vdc =Â 14.5mA (0.5Hz) or 25mA (1Hz)
- Optional BF330CTLIDW white or BF330CTLIDR red cap available for stand-alone use.
- Supplied with a BF431QCP quick connect plate and detector spur wires.
- IP21C rated.
-
-
-
Popular Tags
Best offers
Join Risk Free
30 days refund
100% Safe
Secure Shopping
24x7 Support
Online 24 hours
Best Offers
Grab Now
Free Shiping
On all order over
Know Us
Safetech.hub is the newest online platform envisioned to provide 24/7 online platform for integrators, installers, and end users of Extra Low Voltage (ELV) systems in Nigeria
Read MoreBlog Updates
Maecenas nec venenatis augue unt vel
July 28, 2020
Suspendisse vel eros nulla lig
July 28, 2020
Lacinia quis vel eros donec
July 24, 2020
What’s New In Amoxillin 2020?
May 26, 2020
Become A Fresher In Minimalist Food Festival, Baroque
April 17, 2020
How To Make A Fresh Juice Blended For Your Family?
April 17, 2020
B&O Play – Best Headphone For You
December 16, 2017
Unique Products For Your Kitchen From IKEA Design
December 15, 2017
Explore Fashion Trending For Guys In Autumn 2017
December 14, 2017