Category
- Uncategorized
- Access Control and Time Attendance System
- Accessories
- Addressable base
- Audio
- Cable
- Call Point
- Cameras
- Closed Circuit Television System (CCTV)
- Computer & Laptop
- Door controller
- Fire Alarm System
- Home Appliances
- Manual Callpoints
- Metal Detector
- Naso mask
- New Arrival
- Night Vision
- On Sale
- Security Alarm System
Popular
-
C-Tec FP 8 Zone Conventional Fire Alarm Panel-Ff388-2
₦125,000.00₦120,000.00 -
SOCA SL-130 Dead Bolt Lock ( All purpose type )
₦15,000.00₦13,000.00 -
SOCA SL-100D Dead Bolt Lock ( for automatic door)
₦18,000.00₦15,000.00 - SOCA SL 100A Dead Bolt ₦15,000.00
- Soca SD-30 Armored Door Loop
Tag Clouds
Category: Fire Alarm System
Showing 113–128 of 564 results
-
C-TEC Fire Alarm Control Panel Mains Keyswitch
Read more-
Product dimensions (mm) 82 W x 125 H x D 23mm. Weight 64g. Properties Single pole changeover contacts; Rated at 1A 50V; 50V Isolation between relays, contacts and CFP & relays; 27mA active relay coil current @ 27.6V supply.
-
-
C-TEC Flushing Mount Remote Status Unit Part No. EP210F
Read more-
-
-
- Designed to connect to the RS485 terminals on an EP203 Automatic Extinguisher Panel to provide remote system status indication via a 128 x 64 pixel LCD status display.
- Also includes a pull-down manual release button, a mode (auto/manual) keyswitch and a wide range of system status indicators.
- Three monitored input connections (Hold, Abort and Mode).
- Max. 8 remote status units per EP203 panel.
- Surface remote status units (EP210S) and weather proof enclosures (BF359/1) also available.
-
-
-
-
C-TEC FP 14 Zone Conventional Fire Alarm Panel Part No. FF394-2
₦210,000.00Add to cart-
-
-
-
- DESCRIPTION
- Installer-friendly design.
- Robust metal enclosure c/w lift off lid & heavy-duty base connections.
- 14 conventional Zone circuits.
- Two conventional Sounder circuits.
- Separate indicators for open &Â short circuit fault, sounder fault and battery/power supply fault.
- Non-latching class change sounder output, latching fire &Â non-latching fault outputs (via expansion loom).
- Short circuit=fire facility (pre-1980 BS, no resistors in call points, selectable on a zone by zone basis).
- Ancillary connections for repeaters & other system add-ons including fault relay modules, fire relay modules, sounder delay relay modules, sounder extender kits, etc).
- Multi-lingual variants (subject to quantities).
- Space for 2Â x 12V 7Ah VRLA batteries.
- Compatible with virtually all known conventional fire detectors including C-TEC’s ActiV range.
- Designed to comply with BS 5839-4 (this panel in not compliant with EN54-2/4 and should NOT be used in new UK or European installations).
-
-
-
-
-
C-TEC FP 2 Zone Conventional Fire Alarm Panel Part No. FF382-2
₦78,000.00Add to cart- Installer-friendly design.
- Robust metal enclosure c/w lift off lid & heavy-duty base connections.
- Two conventional Zone circuits.
- Two conventional Sounder circuits.
- Separate indicators for open &Â short circuit fault, sounder fault and battery/power supply fault.
- Non-latching class change sounder output, latching fire &Â non-latching fault outputs (via optional expansion loom).
- Short circuit=fire facility (pre-1980 BS, no resistors in call points, selectable on a zone by zone basis).
- Ancillary connections for repeaters and other system add-ons including fault relay modules, fire relay modules, sounder delay relay modules, sounder extender kits, etc).
- Multi-lingual variants (subject to quantities).
- Space for 2Â x 12V 2.3Ah VRLA batteries.
- Compatible with virtually all known conventional fire detectors including C-TEC’s ActiV range.
- Designed to comply with BS 5839-4
- Download datasheet
-
C-TEC FP 4 Zone Conventional Fire Alarm Panel (expandable to 6 zones) Part No. FF384-2
₦79,000.00Add to cart-
-
-
- Installer-friendly design.
- Robust metal enclosure c/w lift off lid & heavy-duty base connections.
- Four conventional Zone circuits (expandable to 6).
- Two conventional Sounder circuits.
- Separate indicators for open &Â short circuit fault, sounder fault and battery/power supply fault.
- Non-latching class change sounder output, latching fire &Â non-latching fault outputs (via expansion loom).
- Short circuit=fire facility (pre-1980 BS, no resistors in call points, selectable on a zone by zone basis).
- Ancillary connections for repeaters & other system add-ons including fault relay modules, fire relay modules, sounder delay relay modules, sounder extender kits, etc).
- Multi-lingual variants (subject to quantities).
- Space for 2Â x 12V 3.2Ah VRLA batteries.
- Compatible with virtually all known conventional fire detectors including C-TEC’s ActiV range.
- Designed to comply with BS 5839-4 (this panel in not compliant with EN54-2/4 and should NOT be used in new UK or European installations).
-
-
-
-
C-TEC FP 6 Zone Conventional Fire Alarm Panel Part No. FF386-2
Read more-
-
- Installer-friendly design.
- Robust metal enclosure c/w lift off lid & heavy-duty base connections.
- Six conventional Zone circuits.
- Two conventional Sounder circuits.
- Separate indicators for open &Â short circuit fault, sounder fault and battery/power supply fault.
- Non-latching class change sounder output, latching fire &Â non-latching fault outputs (via expansion loom).
- Short circuit=fire facility (pre-1980 BS, no resistors in call points, selectable on a zone by zone basis).
- Ancillary connections for repeaters & other system add-ons including fault relay modules, fire relay modules, sounder delay relay modules, sounder extender kits, etc).
- Multi-lingual variants (subject to quantities).
- Space for 2Â x 12V 3.2Ah VRLA batteries.
- Compatible with virtually all known conventional fire detectors including C-TEC’s ActiV range.
- Designed to comply with BS 5839-4
- Download datasheet
-
-
-
C-TEC FP 8 Zone Conventional Fire Alarm Panel (expandable to 14 zones) Part No. FF388-2
₦160,000.00Add to cart-
-
-
- DESCRIPTION
- Installer-friendly design
- Robust metal enclosure c/w lift off lid & heavy-duty base connections.
- 12 conventional Zone circuits (expandable to 14).
- Two conventional Sounder circuits.
- Separate indicators for open &Â short circuit fault, sounder fault and battery/power supply fault.
- Non-latching class change sounder output, latching fire &Â non-latching fault outputs (via expansion loom).
- Short circuit=fire facility (pre-1980 BS, no resistors in call points, selectable on a zone by zone basis).
- Ancillary connections for repeaters & other system add-ons including fault relay modules, fire relay modules, sounder delay relay modules, sounder extender kits, etc).
- Multi-lingual variants (subject to quantities).
- Space for 2Â x 12V 7Ah VRLA batteries.
- Compatible with virtually all known conventional fire detectors including C-TEC’s ActiV range.
- Designed to comply with BS 5839-4 (this panel in not compliant with EN54-2/4 and should NOT be used in new UK or European installations).
-
-
-
-
C-Tec FP 8 Zone Conventional Fire Alarm Panel-Ff388-2
₦125,000.00₦120,000.00Add to cartC-Tec CFP 8 Zone Conventional Fire Alarm Panel Ff388-2Â Â Ff388-2 certified to EN54-2/4, C-TEC’s CFP 8 zone conventional fire alarm panel offers an array of user and installer-friendly features at a very competitive price. Supplied in an attractive flush or surface mountable plastic enclosure, it includes two detector zones, four conventional sounder circuits, class change …
C-Tec FP 8 Zone Conventional Fire Alarm Panel-Ff388-2Read More
-
C-TEC FP 8 Zone Economy Conventional Fire Alarm Panel Part No. FF388-3
₦120,000.00Add to cart-
-
- Installer-friendly design.
- Robust metal enclosure c/w lift off lid & heavy-duty base connections.
- Eight conventional Zone circuits.
- Two conventional Sounder circuits.
- Separate indicators for open &Â short circuit fault, sounder fault and battery/power supply fault.
- Non-latching class change sounder output, latching fire &Â non-latching fault outputs (via expansion loom).
- Short circuit=fire facility (pre-1980 BS, no resistors in call points, selectable on a zone by zone basis).
- Ancillary connections for repeaters & other system add-ons including fault relay modules, fire relay modules, sounder delay relay modules, sounder extender kits, etc).
- Multi-lingual variants (subject to quantities).
- Space for 2Â x 12V 3.2Ah VRLA batteries.
- Compatible with virtually all known conventional fire detectors including C-TEC’s ActiV range.
- Designed to comply with BS 5839-4 (this panel in not compliant with EN54-2/4 and should NOT be used in new UK or European installations).
-
-
-
C-TEC IP66 Rated Enclosure for EVC302GF or EVC302F Outstations Part No. BF359/1
Read more-
- An attractive IP66 rated enclosure designed for use with a SigTEL EVC302GF or EVC302F flush mounting disabled refuge controller.
- Includes a handle and mounting plate.
- Measures 200 W x 302 H x 123mm deep.
- Textured RAL 7035 (light grey) finish.
- Also compatible with C-TEC’s EP210F remote status units.
-
-
C-TEC Manual ‘Crack Glass’ Call Point, surface Part No. BF370R
Read more- Certified to EN54 Part 11 (LPCB/VdS).
- Unique ‘Plug & Play’ installation concept.
- Supplied with a non-breaking plastic resettable element.
- Includes a 470Ω resistor, test key and red back box.
- Anti-Tamper facility.
- Flush version (without a red back box) also available (order code BF370MFR).
-
C-TEC Manual ‘Crack Glass/No Break’ Call Point, flush/surface Part No. BF370FR
Read more- Certified to EN54 Parts 11 (LPCB)Â and 13 (BSI).
- ‘Universal’ design combines multiple functions into one product, simplifying selection and reducing stock variants.
- Supplied with a glass AND plastic element, a 470Ω AND 680Ω resistor and a red surface mounting back box which can be optionally discarded if flush mounting.
- Quick visible alarm indication.
- Changeover contacts.
- IP24 rated.
-
C-TEC Manual ‘No Break’ Call Point, surface Part No. BF370MR
Read more- Certified to EN54 Part 11 (LPCB/VdS).
- Unique ‘Plug & Play’ installation concept.
- Supplied with a non-breaking plastic resettable element.
- Includes a 470Ω resistor, test key and red back box.
- Anti-Tamper facility.
- Flush version (without a red back box) also available (order code BF370MFR).
-
C-TEC Manual ‘No Break’ Call Point, surface Part No. BF370S
₦5,500.00Add to cart-
- Certified to EN54 Parts 11 (LPCB)Â and 13 (BSI).
- Smooth-action resettable element mimics the feel of breaking glass.
- Supplied with a red back box, reset key and ‘Not in Use’ label.
- Red LED ‘alarm ring’ illuminates call point face upon activation.
- Photoluminescent operating window remains visible for up to 5 minutes.
- Note an additional BF370SFP red flush mounting plate is required if you wish to flush mount the BF370S.
- IP66 weatherproof version (order code BF370S/W) also available.
-
-
C-TEC Manual IP67 ‘Crack Glass’ Call Point, surface Part No. BF370/W
Read more- Certified to EN54 Part 11 (LPCB/VdS).
- Weather resistant and sealed to IP67.
- Ideal for use in external environments where water and dirt are likely to be present.
- Unique ‘Plug & Play’ installation concept.
- Supplied with a glass element.
- Includes a 470Ω resistor and test key.
- Anti-Tamper facility.
- Wide -25ºC to +70ºC operating range.
-
C-TEC MARINE ISOLATOR BASE [SIL2] 45681-211MAR
Read moreThe Marine Isolator Base is unique and designed to only accept the marine isolator.
Popular Tags
Best offers
Join Risk Free
30 days refund
100% Safe
Secure Shopping
24x7 Support
Online 24 hours
Best Offers
Grab Now
Free Shiping
On all order over
Know Us
Safetech.hub is the newest online platform envisioned to provide 24/7 online platform for integrators, installers, and end users of Extra Low Voltage (ELV) systems in Nigeria
Read More