Category
- Uncategorized
- Access Control and Time Attendance System
- Accessories
- Addressable base
- Cable
- Call Point
- Closed Circuit Television System (CCTV)
- Computer & Laptop
- Door controller
- Fire Alarm System
- Manual Callpoints
- Metal Detector
- Naso mask
- New Arrival
- Night Vision
- On Sale
- Security Alarm System
Popular
-
Zeta BreakGlass Yellow
₦ 32,000.00Original price was: ₦ 32,000.00.₦ 31,500.00Current price is: ₦ 31,500.00. -
Zeta Weatherproof Fire Alarm Breakglass Red
₦ 29,000.00Original price was: ₦ 29,000.00.₦ 28,875.00Current price is: ₦ 28,875.00. -
Gent Four-Channel Mains Switching Interface with Enclosure (S4-3440-02)
₦ 1,900,000.00Original price was: ₦ 1,900,000.00.₦ 1,890,000.00Current price is: ₦ 1,890,000.00. -
C-Tec FP 8 Zone Conventional Fire Alarm Panel-Ff388-2
₦ 125,000.00Original price was: ₦ 125,000.00.₦ 120,000.00Current price is: ₦ 120,000.00. -
SOCA SL-130 Dead Bolt Lock ( All purpose type )
₦ 15,000.00Original price was: ₦ 15,000.00.₦ 13,000.00Current price is: ₦ 13,000.00.
Tag Clouds



C-TEC CFP 8 Zone Repeater Panel Part No. CFP760
₦ 300,000.00 Original price was: ₦ 300,000.00.₦ 295,000.00Current price is: ₦ 295,000.00.
-
-
Can be used to repeat the functions of a master CFP standard or AlarmSense 2-8 zone fire panel at remote parts of site (e.g. all potential fire service entrances).
-
Up to 8 repeaters per CFP master.
-
Includes its own Mains power supply that requires its own standby battery supply.
-
Provides the user with access to all AL1 and AL2 functions.
-
Master/Repeater communication achieved using CFP761 network driver cards (one CFP761 is supplied with the Repeater, an additional CF761 card is required at the master CFP).
-
Communicates over screened two-wire fire resistant cable.
-
Total repeater network cable length should not exceed 1KM.
-
Attractive flush or surface mountable plastic lid and enclosure – no bezel required.
-
0 in stock
-
-
CFP 8 Zone Repeater Panel
 CFP760
-
Can be used to repeat the functions of a master CFP standard or AlarmSense 2-8 zone fire panel at remote parts of site (e.g. all potential fire service entrances).
-
Up to 8 repeaters per CFP master.
-
Includes its own Mains power supply that requires its own standby battery supply.
-
Provides the user with access to all AL1 and AL2 functions.
-
Master/Repeater communication achieved using CFP761 network driver cards (one CFP761 is supplied with the Repeater, an additional CF761 card is required at the master CFP).
-
Communicates over screened two-wire fire resistant cable.
-
Total repeater network cable length should not exceed 1KM.
-
Attractive flush or surface mountable plastic lid and enclosure – no bezel required.
-
-
Compatibility
Compatible with C-TEC’s CFP Standard and CFP AlarmSense panels. (CFP Economy panels cannot be extended with this product).
Mains supply
230V 50/60Hz.
Internal power supply
19V-28.5V (27V nominal).
Max battery size and type
2 x 12V 2.1Ah VRLA connected in series for 72 hour standby. 2 x 12V 1.2Ah for 24 hours.
Max. network cable length
1KM.
Product dimensions (mm)
380 W x 235 H x D 96mm.
Construction & finish
Plastic lid and base; RAL7035 textured
IP Rating
IP30.
Weight
1.75kg (without batteries)
Operating conditions/temperature
-5ºC to +40ºC. Max relative humidity: 95%.
-
Weight | 1.75 kg |
---|---|
Dimensions | 380 × 235 × 96 cm |
Related Products
-
Gent Change Over Contact MCP
Read moreGent Change Over Contact is a conventional manual call point, designed to provide a manual
alarm interface to conventional fire alarm control panels. All call points
are supplied in the standard red color and are available in semi-flush
mounting or surface mounting options. The manual call points are all with
a 470 Ohm resistor and Normally Open contact, complete with glass.
Both break glass, and resettable operating elements can be used in the
standard unit by a yellow strip on the element which becomes visible when
activated. -
Gent XENS-829 Weatherproof Manual Call Point 470 Ohms Resistor Glass
Gent XENS-829 Weatherproof Manual Call Point 470 Ohms Resistor Glass
Gent’s range of conventional manual call points are designed to provide a manual alarm interface to conventional fi re alarm control panels. All call points are supplied in the standard red colour and are available in semi-flush mounting or surface mounting options. The manual call points are all with a 470 Ohm resistor and Normally Open contact, complete with glass.
-
Gent Key Operated, Surface Mounted C/W BackBox (XENS-807)
Read moreOur conventional manual call points are designed to provide a manual
alarm interface to conventional fi re alarm control panels. All call points
are supplied in the standard red colour and are available in semi-fl ush
mounting or surface mounting options. The manual call points are all with
a 470 Ohm resistor and Normally Open contact, complete with glass.
Both break glass, and resettable operating elements can be used in the
standard unit by a yellow strip on the element which becomes visible when
activated.
Best offers
Join Risk Free
30 days refund
100% Safe
Secure Shopping
24x7 Support
Online 24 hours
Best Offers
Grab Now
Free Shiping
On all order over
Know Us

Safetech.hub is the newest online platform envisioned to provide 24/7 online platform for integrators, installers, and end users of Extra Low Voltage (ELV) systems in Nigeria
Read More
Reviews
There are no reviews yet.