Category
- Uncategorized
- Access Control and Time Attendance System
- Accessories
- Addressable base
- Cable
- Call Point
- Closed Circuit Television System (CCTV)
- Computer & Laptop
- Door controller
- Fire Alarm System
- Manual Callpoints
- Metal Detector
- Naso mask
- New Arrival
- Night Vision
- On Sale
- Security Alarm System
Popular
-
Zeta BreakGlass Yellow
₦ 32,000.00Original price was: ₦ 32,000.00.₦ 31,500.00Current price is: ₦ 31,500.00. -
Zeta Weatherproof Fire Alarm Breakglass Red
₦ 29,000.00Original price was: ₦ 29,000.00.₦ 28,875.00Current price is: ₦ 28,875.00. -
Gent Four-Channel Mains Switching Interface with Enclosure (S4-3440-02)
₦ 1,900,000.00Original price was: ₦ 1,900,000.00.₦ 1,890,000.00Current price is: ₦ 1,890,000.00. -
C-Tec FP 8 Zone Conventional Fire Alarm Panel-Ff388-2
₦ 125,000.00Original price was: ₦ 125,000.00.₦ 120,000.00Current price is: ₦ 120,000.00. -
SOCA SL-130 Dead Bolt Lock ( All purpose type )
₦ 15,000.00Original price was: ₦ 15,000.00.₦ 13,000.00Current price is: ₦ 13,000.00.
Tag Clouds

Zeta ZT-CP3/W Zeta Conventional Surface Mount Manual Call Point (White)
The ZT-CP3 and ZT-CP3/WP call points are unique in that they mimic the feel of breaking glass whilst offering the user the benefits and environmental advantages of a re-settable operating element. The CP3 uses a simple yet ingenious patented mechanism which consists of a rigid plastic operating element and an over centre spring mechanism. This arrangement provides real action on operation and simulates break glass activation. An activation indicator drops into view at the top of the window after the CP3 has been operated. The unit is then simply reset with a key and is ready for re-use straight away. A special Polycarbonate cover (CP3-CV) is available for extra protection against accidental activation and thus allowing the unit to operate as a double action call point. This must be ordered separately.
Flush Mount Installation
An optional flush mount bezel is available for the indoor ZT-CP3 call point and can be ordered under the code CP3-FMB.
Key Features
- The CP3 is compatible with most conventional fire alarm systems.
- It is safe for use in areas where glass cannot be used, e.g. food processing plants and swimming/leisure centres.
- As the unit can be simply reset it provides an ideal solution for areas that suffer from a high number of false activations such as schools, shopping centres and other public places.
- The IP67 Waterproof CP3 has been designed to deal with today’s harsh environments and the cover adds an extra measure of protection against damage or accidental activation. This is especially useful where emergency systems are involved, and accidental activation could cause serious delays in production or other operations.
- Where risk of malicious activation is a concern, the cover with an optional integral sounder can be highly beneficial. When the cover is lifted, the device emits a piercing 96dB alarm and the prankster will either run or be caught.
- The Waterproof CP3 can also be supplied with an integral cover to prevent accidental damage.
Model Number | Description | Datasheets & Manuals |
---|---|---|
CP3-FMB/W | Abort Call Point Flush Mount Bezel | Datasheet |
Dimensions | 8.7 × 8.8 × 2.5 cm |
---|
Related Products
-
Gent XENS-829 Weatherproof Manual Call Point 470 Ohms Resistor Glass
Gent XENS-829 Weatherproof Manual Call Point 470 Ohms Resistor Glass
Gent’s range of conventional manual call points are designed to provide a manual alarm interface to conventional fi re alarm control panels. All call points are supplied in the standard red colour and are available in semi-flush mounting or surface mounting options. The manual call points are all with a 470 Ohm resistor and Normally Open contact, complete with glass.
-
Gent Key Operated, Surface Mounted C/W BackBox (XENS-807)
Read moreOur conventional manual call points are designed to provide a manual
alarm interface to conventional fi re alarm control panels. All call points
are supplied in the standard red colour and are available in semi-fl ush
mounting or surface mounting options. The manual call points are all with
a 470 Ohm resistor and Normally Open contact, complete with glass.
Both break glass, and resettable operating elements can be used in the
standard unit by a yellow strip on the element which becomes visible when
activated. -
Gent Change Over Contact MCP
Read moreGent Change Over Contact is a conventional manual call point, designed to provide a manual
alarm interface to conventional fire alarm control panels. All call points
are supplied in the standard red color and are available in semi-flush
mounting or surface mounting options. The manual call points are all with
a 470 Ohm resistor and Normally Open contact, complete with glass.
Both break glass, and resettable operating elements can be used in the
standard unit by a yellow strip on the element which becomes visible when
activated.
Best offers
Join Risk Free
30 days refund
100% Safe
Secure Shopping
24x7 Support
Online 24 hours
Best Offers
Grab Now
Free Shiping
On all order over
Know Us

Safetech.hub is the newest online platform envisioned to provide 24/7 online platform for integrators, installers, and end users of Extra Low Voltage (ELV) systems in Nigeria
Read More
Reviews
There are no reviews yet.