Category
- Uncategorized
- Access Control and Time Attendance System
- Accessories
- Addressable base
- Audio
- Cable
- Call Point
- Cameras
- Closed Circuit Television System (CCTV)
- Computer & Laptop
- Door controller
- Fire Alarm System
- Home Appliances
- Manual Callpoints
- Metal Detector
- Naso mask
- New Arrival
- Night Vision
- On Sale
- Security Alarm System
Popular
-
C-Tec FP 8 Zone Conventional Fire Alarm Panel-Ff388-2
₦125,000.00₦120,000.00 -
SOCA SL-130 Dead Bolt Lock ( All purpose type )
₦15,000.00₦13,000.00 -
SOCA SL-100D Dead Bolt Lock ( for automatic door)
₦18,000.00₦15,000.00 - SOCA SL 100A Dead Bolt ₦15,000.00
- Soca SD-30 Armored Door Loop
Tag Clouds
GENT 8 ZONE REPEAT INDICATOR, LESS BATTERIES (13271-08LB)
₦265,000.00 ₦255,000.00
Gent 13271-08LB 8 Zone Xenex Conventional Fire Alarm Repeat Panel EN54 (Less Batteries)
BSI approved to EN54: Parts 2 & 4, the Xenex control panel can be used on installations meeting BS 5839:Part1. Control panel options for 2-8 zones can be specified.
Designed to simplify system installation, each Xenex panel contains an integral power supply and battery support to drive up to 8 alarm sounder circuits, 2 auxiliary relay contacts, a zone disablement facility and also one-man test and commissioning features.
Utilising LPCB approved conventional smoke or heat detectors, Xenex offers exceptional value for money.
GENTÂ REPEAT INDICATOR, LESS BATTERIES (13271-08LB)
Gent 8-ZONE REPEAT INDICATOR can be used on installations meeting BS 5839:Part1 & is BSI approved to EN54: Parts 2 & 4. Control panel options for 2-8 zones can be specified.
Designed to simplify system installation, each Xenex panel contains an integral power supply and battery support to drive up to 8 alarm sounder circuits, 2 auxiliary relay contacts, a zone disablement facility, and also one-man test and commissioning features.
Using LPCB-approved conventional smoke or heat detectors, Xenex offers exceptional value for money.
Key Features
- Xenex deploys devices on conventional radial wiring layouts using standard 2-core cable
- Device options include a full range of smoke detectors (optical, beam and duct types), heat detectors (fixed temperature or rate of rise types), sounders, strobes and bells
- Sounder options include shallow base, deep base and bedhead sounder types
- For installations where a high degree of weatherproofing is required, IP55 rated sounders, sirens and bells are available
- Common accessories such as manual call points (standard IP54 rated or key operated anti-vandal types, available as either surface mounted or flush-fitted models), door release units and Xenon flashers can all be accommodated
- Spare test keys (for testing manual call points without breaking the glass), spare glasses (packs of 10) and False alarm verification feature to filter out false alarms is selectable through software
-
Technical Data Approval BSI Approved (KM 553763) CPD Number 0086-CPD-553764 Cable Type BS 6387, 2 core, min 1.5mm2 CSA Class Change Facility Volt free contact – max distance 100m Operating Temperature Indoor, 0 – 40ºC Relevant Standard EN54: Parts 2 &4
Weight | 6.2 kg |
---|---|
Dimensions | 39.5 × 27.4 × 8.7 cm |
Related products
-
Solo 823 Smoke & Cordless Heat Detector Test Set 9.3 Metres
₦2,500,000.00₦2,261,000.00Add to cartSolo 823 Smoke & Cordless Heat Detector Test Set 9.3 metres Solo equipment is available in a number of conveniently arranged kits. Whether your need is for a simple starter kit, a universal smoke testing kit, or an all encompassing kit including a heat detector tester, there is one available. Larger kits are supplied with …
Solo 823 Smoke & Cordless Heat Detector Test Set 9.3 MetresRead More
-
Reset Call Point Waterproof Reset Call Point
₦23,000.00₦21,000.00Add to cartDESCRIPTION
The ZT-CP3 and ZT-CP3/WP call points are
unique in that they mimic the feel of breaking
glass whilst offering the user the benefits and
environmental advantages of a re-settable
operating element.
The CP3 uses a simple yet ingenius patented mechanism
which consists of a rigid plastic operating element and
an over centre spring mechanism. This arrangement
provides real action on operation and simulates break
glass activation. -
Gent Single Mode Fibre Network Card (VIG-NC-SMF)
₦440,000.00Add to cartThe Single Mode Fibre Network Card (VIG-NC-SMF) allows a fast and reliable network over distances of up to 20km between Vigilon Plus Panels (VIGPLUS-24, VIGPLUS-72) / Network Nodes (VIGPLUS-NODE).
The Single Mode Fibre Network card is designed to plug into the backplane of a panel or node in dedicated slots.
Fibre optic connects directly to the sockets on the card.
Up to 31 panels/nodes on a single network.
Up to 200 panels/nodes on a complex networks. -
Gent Surface MCP (XENS-805) 470 Ohms Re-settable
₦12,000.00₦10,000.00Add to cartGent XENS-805 Surface MCP 470 Ohms Re-settable Gent Surface MCP (XENS-805) 470 Ohms Re-settable requires no hammer and is easy and safe to operate. Gent’s conventional manual call points are designed to provide a manual alarm interface to conventional fire alarm control panels. All call points are supplied in the standard red colour and are …
Popular Tags
Best offers
Join Risk Free
30 days refund
100% Safe
Secure Shopping
24x7 Support
Online 24 hours
Best Offers
Grab Now
Free Shiping
On all order over
Know Us
Safetech.hub is the newest online platform envisioned to provide 24/7 online platform for integrators, installers, and end users of Extra Low Voltage (ELV) systems in Nigeria
Read More
Reviews
There are no reviews yet.