Category
- Uncategorized
- Access Control and Time Attendance System
- Accessories
- Addressable base
- Audio
- Cable
- Call Point
- Cameras
- Closed Circuit Television System (CCTV)
- Computer & Laptop
- Door controller
- Fire Alarm System
- Home Appliances
- Manual Callpoints
- Metal Detector
- Naso mask
- New Arrival
- Night Vision
- On Sale
- Security Alarm System
Popular
-
C-Tec FP 8 Zone Conventional Fire Alarm Panel-Ff388-2
₦125,000.00₦120,000.00 -
SOCA SL-130 Dead Bolt Lock ( All purpose type )
₦15,000.00₦13,000.00 -
SOCA SL-100D Dead Bolt Lock ( for automatic door)
₦18,000.00₦15,000.00 - SOCA SL 100A Dead Bolt ₦15,000.00
- Soca SD-30 Armored Door Loop
Tag Clouds
Gent S4 O2-HCO Dual Optical Heat-Sensor Voice Sounder High Power White VAD – S4-911-V-VAD-HPW
₦79,000.00
DESCRIPTION
Gent S4 CO Dual Optical Heat Sensor Voice Sounder High Power White VAD – S4-911-V-VAD-HPW
The S-Quad range of multifunction devices includes sensors with sounder, speech and EN54-23 certified visual alarms. This allows the maximum flexibility for designers providing cover for a building. The advanced sensing technology is enhanced with a device that can alert building occupants with a highly visible visual alarm and a recorded voice message to ensure all occupants are alerted to an emergency.
Innovative design has allowed the LED visual alarm to be built into the centre of the sensor with the sounder and speech circuits inside providing a neat and aesthetic solution to multi-function devices.
Gent S4 O2-HCO Dual Optical Heat-Sensor Voice Sounder High Power White VAD – S4-911-V-VAD-HPW
Gent S4 O2-HCO Dual Optical Heat-Sensor Voice Sounder High Power White VAD – S4-911-V-VAD-HPW is [part of the S-Quad range of multifunction devices. The S-Quad range of multifunction devices includes sensors with sounders, speech and EN54-23 certified visual alarms. This allows maximum flexibility for designers providing cover for a building. The advanced sensing technology is enhanced with a device that can alert building occupants with a highly visible visual alarm and a recorded voice message to ensure all occupants are alerted to an emergency.
Innovative design has allowed the LED visual alarm to be built into the center of the sensor with the sounder and speech circuits inside providing a neat and aesthetic solution to multi-function devices.
KEY FEATURES
- Â Complete range of sensors with combinations of advanced sensing technologies including heat, dual angle optical scatter and carbon monoxide (CO)
- Combined sensing of carbon monoxide with dual angle optical scatter and heat allows a higher level of false alarm immunity in presence of steam and while still maintaining the integrity of detecting fires
- Each sensor has certified sensitivity settings that suit certain environments/ applications and may be programmed for different times of the day if required • Short circuit Isolator in each device
- Â Configurable input/ output connection for a remote indicator or supervisory input fully synchronised sound patterns via the control panel
- Sensor sounders have adjustable sound levels and tones to match system sounders
- Sounder element monitoring and over-load protection to ensure operation even in event of cable fault
- Â Sound output synchronised and compatible with S-Quad range of EN54-23 VADs
- Sensor and alarm in one device reduce installation time and cost.
- Built-in high-intensity VAD helps alert occupants in noisy environments as well as the hard of hearing
SPECIFICATION
- OPERATING TEMPERATURE: -10 to +50°C
- WEIGHT: 0.11kg ( 0.17kg inc Base)
- DEVICE / LOOP LOADING: 200 devices per Loop (assumes 800mA Loop Card)
- COLOUR: White
Weight | 0.11 kg |
---|---|
Dimensions | 11.7 × 4.96 cm |
Related products
-
Gent CWST-RW-S5 VAD Red Base – White Flash
Read moreCWST-RW-S5 features high output LEDs, advanced optics and an innovative lens design, providing outstanding Omni-directional light coverage at low current draw. Specifically designed for, and approved to meet EN54-23. The CWST-RW-S5 delivers outstanding quality, reliability and long operational life.
-
Zeta Fyreye MkII Conventional Heat Detectors MKII-HF/CS90
₦9,500.00Add to cartDESCRIPTION
The Fyreye Rate of Rise heat detectors (MKII-HFCS90) use a thermistor arrangement to sense a quick rise in
temperature and also a final threshold temperature of 90°C. The Fyreye fixed heat detector (MKII-HF/CS90) has a single thermistor arrangement that gives an alarm at a temperature of 90°C.
There are 4 types of mounting base available; standard or deep and with or without diode. -
Gent Flush Manual Call Point (XENS-850) 470 Ohms Glass
Read moreGent XENS-850 Flush Manual Call Point 470 Ohms Glass
Gent Flush Manual Call Point are designed to provide a manual alarm interface to conventional fire alarm control panels. All call points are supplied in the standard red colour and are available in semi-flush mounting or surface mounting options. The manual call points are all with a 470 Ohm resistor and Normally Open contact, complete with glass.
Both break glass, and resettable operating elements can be used in the standard unit by a yellow strip on the element which becomes visible when activated.
With the addition of a hinged transparent cover the element may be protected against accidental operation.
A specialist test key may be inserted into the bottom of the unit to lower the glass and release the micro-switch and thus a full functional test is achieved.
-
Zeta Fyreye MKII Diode Base
₦1,500.00Add to cartDESCRIPTION
Fyreye MKII Diode Base
Low profile or deep diode mounting base for the Fyreye MKII range of conventional detectors.
Popular Tags
Best offers
Join Risk Free
30 days refund
100% Safe
Secure Shopping
24x7 Support
Online 24 hours
Best Offers
Grab Now
Free Shiping
On all order over
Know Us
Safetech.hub is the newest online platform envisioned to provide 24/7 online platform for integrators, installers, and end users of Extra Low Voltage (ELV) systems in Nigeria
Read More
Reviews
There are no reviews yet.