Category
- Uncategorized
- Access Control and Time Attendance System
- Accessories
- Addressable base
- Cable
- Call Point
- Closed Circuit Television System (CCTV)
- Computer & Laptop
- Door controller
- Fire Alarm System
- Manual Callpoints
- Metal Detector
- Naso mask
- New Arrival
- Night Vision
- On Sale
- Security Alarm System
Popular
-
Zeta BreakGlass Yellow
₦ 32,000.00Original price was: ₦ 32,000.00.₦ 31,500.00Current price is: ₦ 31,500.00. -
Zeta Weatherproof Fire Alarm Breakglass Red
₦ 29,000.00Original price was: ₦ 29,000.00.₦ 28,875.00Current price is: ₦ 28,875.00. -
Gent Four-Channel Mains Switching Interface with Enclosure (S4-3440-02)
₦ 1,900,000.00Original price was: ₦ 1,900,000.00.₦ 1,890,000.00Current price is: ₦ 1,890,000.00. -
C-Tec FP 8 Zone Conventional Fire Alarm Panel-Ff388-2
₦ 125,000.00Original price was: ₦ 125,000.00.₦ 120,000.00Current price is: ₦ 120,000.00. -
SOCA SL-130 Dead Bolt Lock ( All purpose type )
₦ 15,000.00Original price was: ₦ 15,000.00.₦ 13,000.00Current price is: ₦ 13,000.00.
Tag Clouds

C-TEC EP203 Automatic Extinguisher Panel Part No. EP203
₦ 600,000.00 Original price was: ₦ 600,000.00.₦ 570,000.00Current price is: ₦ 570,000.00.
-
Technical Specifications
-
Approvals/certifications Certified to EN12094-1 and EN54-2 & 4 by the LPCB.
-
Mains supply 230V 50/60Hz.
-
Mains rated current 810mA max.
-
Internal power supply 19V-28.5V (27V nominal). Ripple 7V maximum (battery fault).
-
Total output current limited to 1.5A @ 230Vac continuous, 3A peak (ImaxA eq 800mA).
-
Quiescent current 40mA (on mains fail). Zone quiescent 2mA max.
-
Max battery size and type 2 x 12V 7Ah VRLA connected in series.
-
No. of detector zone circuits 3 @ 19-28Vdc (Max. length per circuit is 250m).
-
Max. devices per detector zone 20 detectors (or 32 detectors/manual call points combined).
-
No. of conventional sounder circuits 3 (two x 1st stage; one x 2nd stage). Max. length per circuit is 50m).
-
EOL resistor value 6800 5% Tol. 0/25W (blue, grey, red, gold).
-
Max. sounder output current 3 x 200mA.
-
Auxiliary relays Six: (1) Fire; (2) Local Fire; (3) Extract Fan; (4) 1st Stage; (5) 2nd Stage; (6) Fault. Volt free single pole
changeover. Max. switch current 1A; Max. switch voltage 30Vdc. Five additional relays available via
EP212 relay card.
Other outputs Extinguishant release (21-28Vdc, rated at 1A for 5 mins). Programmable to delay by 0-60 seconds; to
be active for 1-300 seconds and to flood for 60-1800 seconds.
Auxiliary inputs Six: (1) Manual Release; (2) Flow Switch; (3) Low Pressure; (4) Mode; (5) Hold; (6) Abort. 8K-2K normal;
1.8K-200 active; 150-0 short circuit. EOL value: 6K8 +/-5%, 0.25W.
Indicators Multiple indicators are provided – refer to the EP203 instructions for details.
Controls Extinguishant release (housed in yellow casing); Accessed keyswitch; Operation keyswitch (Manual
only or Manual & Auto); Buttons for Menu; Silence internal sounder; reset panel; silence/resound
sounders and scrolling.
Expansion connections Yes – for up to 8 x Remote status units (2 wire RS485 + 2 wire power) and/or up to 8 x Ecomomy
status units (2 wire power + 2 wire mode select).
Product dimensions (mm) 439 W x 276 H x 70 D mm (back box); 467 W x 293 H x 29 D mm (lid).
Construction & finish Metal back box; metal chassis’ plastic lid.
IP Rating IP30.
Weight 4.2kg (without batteries).
Operating conditions/temperature -5°C to +40°C. Max relative humidity: 95%
0 in stock
Protect What Matters with Precision – C-TEC EP203 Automatic Extinguisher Panel
Engineered for rapid response and reliable performance, the C-TEC EP203 is your trusted solution for automatic fire suppression. Designed to detect, alert, and activate extinguishing systems in critical moments, the EP203 delivers unmatched safety for server rooms, electrical enclosures, and high-risk environments.
With intelligent control features, user-friendly interface, and industry-standard reliability, the EP203 ensures your property and people are protected—automatically.
C-TEC EP203 – Because fire protection should never be second best.
LPCB certified to EN 12094-1 (the European standard for Fixed Firefighting Systems – Components for Gas Extinguishing Systems) and EN54-2/4, the EP203 three zone automatic extinguisher panel epitomises quality, durability and reliability.
Specifically designed for use in areas housing expensive, dangerous or irreplaceable items of equipment, it features an intuitive 128 x 64-pixel display that gives clear and concise feedback to the user, installer and commissioning engineer. It has six monitored inputs (including hold & abort), a time stamped log, adjustable flood times and volt-free changeover relays for fire, local fire, 1st stage active, 2nd stage active, extractor fan and fault.
All of the panel’s electronics – apart from its powerful 3A EN54-4 switch mode PSU – are mounted on a detachable metal bridge plate for ease of installation. A wide range of ancillaries are also available including remote status units, hold-off & abort buttons, line terminators and relay boards.
Weight | 4.2 kg |
---|---|
Dimensions | 276 × 439 × 70 cm |
Related Products
-
Gent XENS-829 Weatherproof Manual Call Point 470 Ohms Resistor Glass
Gent XENS-829 Weatherproof Manual Call Point 470 Ohms Resistor Glass
Gent’s range of conventional manual call points are designed to provide a manual alarm interface to conventional fi re alarm control panels. All call points are supplied in the standard red colour and are available in semi-flush mounting or surface mounting options. The manual call points are all with a 470 Ohm resistor and Normally Open contact, complete with glass.
-
Gent Key Operated, Surface Mounted C/W BackBox (XENS-807)
Read moreOur conventional manual call points are designed to provide a manual
alarm interface to conventional fi re alarm control panels. All call points
are supplied in the standard red colour and are available in semi-fl ush
mounting or surface mounting options. The manual call points are all with
a 470 Ohm resistor and Normally Open contact, complete with glass.
Both break glass, and resettable operating elements can be used in the
standard unit by a yellow strip on the element which becomes visible when
activated. -
Gent Change Over Contact MCP
Read moreGent Change Over Contact is a conventional manual call point, designed to provide a manual
alarm interface to conventional fire alarm control panels. All call points
are supplied in the standard red color and are available in semi-flush
mounting or surface mounting options. The manual call points are all with
a 470 Ohm resistor and Normally Open contact, complete with glass.
Both break glass, and resettable operating elements can be used in the
standard unit by a yellow strip on the element which becomes visible when
activated.
Best offers
Join Risk Free
30 days refund
100% Safe
Secure Shopping
24x7 Support
Online 24 hours
Best Offers
Grab Now
Free Shiping
On all order over
Know Us

Safetech.hub is the newest online platform envisioned to provide 24/7 online platform for integrators, installers, and end users of Extra Low Voltage (ELV) systems in Nigeria
Read More
Reviews
There are no reviews yet.