Category
- Uncategorized
- Access Control and Time Attendance System
- Accessories
- Addressable base
- Audio
- Cable
- Call Point
- Cameras
- Closed Circuit Television System (CCTV)
- Computer & Laptop
- Door controller
- Fire Alarm System
- Home Appliances
- Manual Callpoints
- Metal Detector
- Naso mask
- New Arrival
- Night Vision
- On Sale
- Security Alarm System
Popular
-
C-Tec FP 8 Zone Conventional Fire Alarm Panel-Ff388-2
₦125,000.00₦120,000.00 -
SOCA SL-130 Dead Bolt Lock ( All purpose type )
₦15,000.00₦13,000.00 -
SOCA SL-100D Dead Bolt Lock ( for automatic door)
₦18,000.00₦15,000.00 - SOCA SL 100A Dead Bolt ₦15,000.00
- Soca SD-30 Armored Door Loop
Tag Clouds
C-TEC Sounder Isolator Module (max. 30 per BF365SC) Part No. BF365IM
- A fault isolating module with sounder drive capability designed to meet requirement 17.9.2c of Dutch standard NEN2575.
- BSI certified to EN54 parts 17 & 18.
- Measures just 55mm x 55mm x 16mm (will fit in the base of most conventional sounders).
- Up to 30 BF365IM modules per BF365SC controller.
- Allows low-cost, non-fire resistant sounder circuit cabling to be used when used in conjunction with our BF365SC Sounder Isolator Controller (subject to fire officer approval).
- Wiring must be made in a loop arrangement, beginning and ending at the controller.
- If a wiring fault should occur, the Module(s) nearest to the faulty section of cabling will, if needed, isolate this section. As the Modules are driven from each direction, any loss of cable integrity will have no effect on the functionality of the actual sounders.
Approvals/certifications | BSI certified to EN54-17: 2005 (Short-circuit isolators) and EN54-18 (Input-output devices). |
Compatibility | Will work with fire panels that totally reverse sounder circuit polarity (requires a BS365SC Isolator Controller) |
Quiescent current | 250uA. |
Product dimensions (mm) | 55 W x 55 H x D 16mm. |
Construction & finish | Supplied on a white PVC plate. |
Weight | TBC. |
Operating conditions/temperature | -10ºC to +60ºC. |
Notes | Max. Controllers per sounder circuit is 10; Max Loop Modules per Controller is 30; CIE Sounder Trigger Range is 15-30VDC |
Related products
-
Zeta Fyreye MkII Conventional Heat Detectors MKII-HF/CS90
₦9,500.00Add to cartDESCRIPTION
The Fyreye Rate of Rise heat detectors (MKII-HFCS90) use a thermistor arrangement to sense a quick rise in
temperature and also a final threshold temperature of 90°C. The Fyreye fixed heat detector (MKII-HF/CS90) has a single thermistor arrangement that gives an alarm at a temperature of 90°C.
There are 4 types of mounting base available; standard or deep and with or without diode. -
C-TEC ActiV Conventional Base Voice Sounder Part No. BF454C/CC/W
Read more-
-
- Superb sound intelligibility.
- Choose from two evacuation voice messages and four evacuation alarm tones (your selected evacuation message will be preceded by the selected tone).
- Alarm Current at 30Vdc = 10mA.
- Alarm Current at 18Vdc = 8mA.
- Optional BF330CTLIDW white or BF330CTLIDR red cap available for stand-alone use.
- Supplied with a BF431QCP quick connect plate and detector spur wires.
- IP21C rated.
-
-
-
Zeta ID2/4/M Infinity ID2 Intelligent 2 Wire 4 Zone Fire Panel in Metal Enclosure
Read moreDescription
Zeta Alarm Systems is proud to introduce the most
advanced
2 wire system on the market. We can now
provide
a system that gives all of the benefits associated
with
a ‘2 Wire’ installation (less cable, quicker installation,
cost savings on labour/product) and has the facility to
‘I.D.’ the devices.
The system is built on the proven communication protocol
developed by Zeta Alarm Systems and shares the same
platform as our largest, most powerful system.
The ID2 can be used for new installations, as
a retrofit for any conventional system or as a replacement for
existing
2 wire systems when the extra features are
deemed to be desirable/necessary. This is possible
because the ID2 devices sit on radial circuits, thus
making it easy to ‘upgrade’
a system with the facility to
I.D. devices without the need to re-wire.
Technical -
C-TEC ActiV Conventional ‘O Class’ Base VAD c/w Voice Sounder Part No. BF455C/CC/W
Read more-
-
-
- Superb sound intelligibility.
- Choose from two evacuation voice messages and four evacuation alarm tones (your selected evacuation message will be preceded by the selected tone).
- Provides ‘O-R-3-2.5-17’ light distribution using the same lenses and electronics as our EN54-3 & 23 certified base sounder VAD.
- Three selectable VAD flash rates (0.5Hz, 1Hz, OFF)
- Alarm Current at 30Vdc =Â 17mA (0.5Hz) or 24mA (1Hz)
- Alarm Current at 18Vdc =Â 18.5mA (0.5Hz) or 30mA (1Hz)
- Optional BF330CTLIDW white or BF330CTLIDR red cap available for stand-alone use.
- Supplied with a BF431QCP quick connect plate and detector spur wires.
- IP21C rated.
-
-
-
Popular Tags
Best offers
Join Risk Free
30 days refund
100% Safe
Secure Shopping
24x7 Support
Online 24 hours
Best Offers
Grab Now
Free Shiping
On all order over
Know Us
Safetech.hub is the newest online platform envisioned to provide 24/7 online platform for integrators, installers, and end users of Extra Low Voltage (ELV) systems in Nigeria
Read More
Reviews
There are no reviews yet.