Category
- Uncategorized
- Access Control and Time Attendance System
- Accessories
- Addressable base
- Audio
- Cable
- Call Point
- Cameras
- Closed Circuit Television System (CCTV)
- Computer & Laptop
- Door controller
- Fire Alarm System
- Home Appliances
- Manual Callpoints
- Metal Detector
- Naso mask
- New Arrival
- Night Vision
- On Sale
- Security Alarm System
Popular
-
C-Tec FP 8 Zone Conventional Fire Alarm Panel-Ff388-2
₦125,000.00₦120,000.00 -
SOCA SL-130 Dead Bolt Lock ( All purpose type )
₦15,000.00₦13,000.00 -
SOCA SL-100D Dead Bolt Lock ( for automatic door)
₦18,000.00₦15,000.00 - SOCA SL 100A Dead Bolt ₦15,000.00
- Soca SD-30 Armored Door Loop
Tag Clouds
General Description
The detector has wide-angle sensitivity that can reliably and quickly detect weak ultraviolet radiations emitted by flame. It will not react to room illuminations, infrared or other light sources unrelated to real fire.
Applications
- Premises with higher ceilings: theater, gym, storage, gallery or warehouse, etc.
- Places where fires happen easily: places storing with combustible goods, gas stations, factory working places, machine rooms, etc.
- Ventilate places: open markets, station platforms, hotel lobbies, department stores, etc. (places that smoke and heat can not gather during early period of fire)
- Others: tunnels, computer rooms, etc.
Installation Instructions
- Install at obstruction-free places.
- Avoid installing near mercury lamps, halogen lamps and sterilization lamps.
- Avoid installing within sensitive range of welding sparks and radiation.
Model | AH-0014 | ||
Type | 2 wire | 3 wire | 4 wire |
Alarm Contact | N/A | N/A | 0.8A @30V DC, 0.4A @125V AC |
Voltage Range | 12 ~ 30V DC | ||
Alarm Current @24V DC 470Ω | 40mA | 40mA | 35mA |
Standby Current @24V DC 470Ω | under 100μA | ||
Sensor Type | Ultraviolet | ||
Sensitivity Angle | 120° | ||
Sensitivity Range | It can detect flame of 15mm at distance of 3m | ||
Ambient Temperature | -10℃ ~ +55℃ | ||
Material | Fire-proof plastic | ||
Dimensions | 111mm(Dia.) x 47mm(H) | ||
Weight | About 170g | ||
Color | White |
Catalogue
Manual
Related products
-
Gent Flush Manual Call Point (XENS-850) 470 Ohms Glass
Read moreGent XENS-850 Flush Manual Call Point 470 Ohms Glass
Gent Flush Manual Call Point are designed to provide a manual alarm interface to conventional fire alarm control panels. All call points are supplied in the standard red colour and are available in semi-flush mounting or surface mounting options. The manual call points are all with a 470 Ohm resistor and Normally Open contact, complete with glass.
Both break glass, and resettable operating elements can be used in the standard unit by a yellow strip on the element which becomes visible when activated.
With the addition of a hinged transparent cover the element may be protected against accidental operation.
A specialist test key may be inserted into the bottom of the unit to lower the glass and release the micro-switch and thus a full functional test is achieved.
-
APOLLO AlarmSense Base Sounder/Visual Indicator Part No. 45681-509APO
Read more- Will accept any AlarmSense fire detector to provide fire detection and an audible AND visual alarm warning signal at the same point.
- 70d-87dB(A) sound output (visual indicator activates with sounder).
- Certified to EN54-3 by UL International (UK) Limited.
- Suitable for use with C-TEC’s CFP AlarmSense range of 2-8 Zone Two-Wire Fire Panels.
- AlarmSense priority/non priority signal recognition
- Detects the removal of a detector head and reports a fault
- Continues to work during unauthorised removal of detector.
- High and low volume ranges.
- Red and white caps available for stand-alone use.
- Can also be purchased as part of a detector/sounder visual indicator base combination (see Combination AlarmSense Devices section below).
-
Zeta Infinity 8 Conventional 1 Zone Fire Alarm Panel IN1
₦139,000.00₦127,000.00Add to cartDESCRIPTION
The Infinity 8 control panel is housed in the
most attractive, modern designed, flame
retardent ABS enclosure, utilising a switch
mode power supply. It has a fully removable
front cover which improves ease of access for
cable installations.
The Infinity 8 panel can also be ordered with a metal back
box facilitating upto 7ah batteries to fit within the panel
housing. To order this version add “/M” to the end of the
model number (i.e. IN1/M, IN2/M, etc.) -
C-TEC ActiV 96dB(A) Conventional Base Sounder Part No. BF431C/CC/W
Read more-
- Third-party certified to EN54-3 (Sounders).
- Impressive 96dB(A) sound output @ 1m.
- Includes 31 selectable primary tones and an optional secondary tone.
- Two volume levels (high and low)
- Alarm Current at 30Vdc = 5.5mA
- Alarm Current at 18Vdc = 3.8mA
- Optional BF330CTLIDW white or BF330CTLIDR red cap available for stand-alone use.
- Supplied with a BF431QCP quick connect plate and detector spur wires.
- IP21C rated.
-
Popular Tags
Best offers
Join Risk Free
30 days refund
100% Safe
Secure Shopping
24x7 Support
Online 24 hours
Best Offers
Grab Now
Free Shiping
On all order over
Know Us
Safetech.hub is the newest online platform envisioned to provide 24/7 online platform for integrators, installers, and end users of Extra Low Voltage (ELV) systems in Nigeria
Read More
Reviews
There are no reviews yet.