UL Listed.
The standard detector is 2-wire or 3-wire with base.
For 4-wire type just add one relay output module on 3-wire base. Simple and easy module placement enables wider application.
Twin-color LED display enables viewer to easily identify the current status of detector.
Contacts material is highly acid-resistant and rust-resistant.
Detector is made of high endurance, solid and colorfast Fire-proof plastic.
Non-loosening screws on base terminal for easy installation.
Detector has passed strict EMC test, which greatly eliminates false alarms caused by interference from nearby sources.
₦ 25,200.00₦ 26,400.00
Quick view Add to wishlist
EN54-7 Approval.
The standard detector is 2-wire or 3-wire with base.
For 4-wire type just add one relay output module on 3-wire base. Simple and easy module placement enables wider application.
Dual LEDs for 360-degree visibility. Bi-color LED, Stand-by Status: Green; Alarm Status: Red.
Detector is made of high endurance, solid and colorfast Fire-proof plastic.
Non-loosening screws on base terminal for easy installation.
Detector has passed strict EMC test, which greatly eliminates false alarms caused by interference from nearby sources.
₦ 21,525.00₦ 22,550.00
Quick view Add to wishlist
₦ 223,650.00₦ 234,300.00
Quick view Add to wishlist
₦ 53,550.00₦ 56,100.00
Quick view Add to wishlist
Quick view Add to wishlist
Can be used to repeat the functions of a master CFP standard or AlarmSense 2-8 zone fire panel at remote parts of site (e.g. all potential fire service entrances).
Up to 8 repeaters per CFP master.
Includes its own Mains power supply that requires its own standby battery supply.
Provides the user with access to all AL1 and AL2 functions.
Master/Repeater communication achieved using CFP761 network driver cards (one CFP761 is supplied with the Repeater, an additional CF761 card is required at the master CFP).
Communicates over screened two-wire fire resistant cable.
Total repeater network cable length should not exceed 1KM.
Attractive flush or surface mountable plastic lid and enclosure – no bezel required.
₦ 295,000.00₦ 300,000.00
Quick view Add to wishlist
Technical Specifications
Approvals/certifications Certified to EN12094-1 and EN54-2 & 4 by the LPCB.
Mains supply 230V 50/60Hz.
Mains rated current 810mA max.
Internal power supply 19V-28.5V (27V nominal). Ripple 7V maximum (battery fault).
Total output current limited to 1.5A @ 230Vac continuous, 3A peak (ImaxA eq 800mA).
Quiescent current 40mA (on mains fail). Zone quiescent 2mA max.
Max battery size and type 2 x 12V 7Ah VRLA connected in series.
No. of detector zone circuits 3 @ 19-28Vdc (Max. length per circuit is 250m).
Max. devices per detector zone 20 detectors (or 32 detectors/manual call points combined).
No. of conventional sounder circuits 3 (two x 1st stage; one x 2nd stage). Max. length per circuit is 50m).
EOL resistor value 6800 5% Tol. 0/25W (blue, grey, red, gold).
Max. sounder output current 3 x 200mA.
Auxiliary relays Six: (1) Fire; (2) Local Fire; (3) Extract Fan; (4) 1st Stage; (5) 2nd Stage; (6) Fault. Volt free single pole
changeover. Max. switch current 1A; Max. switch voltage 30Vdc. Five additional relays available via
EP212 relay card.
Other outputs Extinguishant release (21-28Vdc, rated at 1A for 5 mins). Programmable to delay by 0-60 seconds; to
be active for 1-300 seconds and to flood for 60-1800 seconds.
Auxiliary inputs Six: (1) Manual Release; (2) Flow Switch; (3) Low Pressure; (4) Mode; (5) Hold; (6) Abort. 8K-2K normal;
1.8K-200 active; 150-0 short circuit. EOL value: 6K8 +/-5%, 0.25W.
Indicators Multiple indicators are provided – refer to the EP203 instructions for details.
Controls Extinguishant release (housed in yellow casing); Accessed keyswitch; Operation keyswitch (Manual
only or Manual & Auto); Buttons for Menu; Silence internal sounder; reset panel; silence/resound
sounders and scrolling.
Expansion connections Yes – for up to 8 x Remote status units (2 wire RS485 + 2 wire power) and/or up to 8 x Ecomomy
status units (2 wire power + 2 wire mode select).
Product dimensions (mm) 439 W x 276 H x 70 D mm (back box); 467 W x 293 H x 29 D mm (lid).
Construction & finish Metal back box; metal chassis’ plastic lid.
IP Rating IP30.
Weight 4.2kg (without batteries).
Operating conditions/temperature -5°C to +40°C. Max relative humidity: 95%
₦ 570,000.00₦ 600,000.00
Quick view Add to wishlist
Designed to connect to the RS485 terminals on an EP203 Automatic Extinguisher Panel to provide remote system status indication via a 128 x 64 pixel LCD status display.
Also includes a pull-down manual release button, a mode (auto/manual) keyswitch and a wide range of system status indicators.
Three monitored input connections (Hold, Abort and Mode).
Max. 8 remote status units per EP203 panel.
Surface remote status units (EP210S) and weather proof enclosures (BF359/1) also available.