FS20X-211-24-6: Dual IR/UV Flame Detector (Stainless Steel)
Based on the foundation of the highly successful and reliable SS4 detector, the FS20X detector represents a quantum leap
in integrating Infrared and Ultraviolet sensing technologies. The FS20X detector is a Multi-Spectrum and UV/Dual IR/VIS
and flame detector with a proven UV solar-blind sensor. FS20X delivers a faster response and fewer false alarms, performs in
a wider ambient temperature range, with a much longer detection range compared to conventional UV/IR detectors. -
C-TEC MARINE ISOLATOR BASE [SIL2] 45681-211MAR
The Marine Isolator Base is unique and designed to only accept the marine isolator.
-
C-TEC MFP 16 Zone Conventional Fire Alarm Panel (expandable to 28 zones) Part No. FF516
-
-
- DESCRIPTION
- Microprocessor based design.
- Robust metal enclosure c/w lift off lid & heavy-duty base connections.
- 28 conventional Zone circuits.
- 4 conventional Sounder circuits.
- Separate indicators for open circuit, short circuit, head-out, sounder & battery/power supply faults.
- Non-latching class change sounder input, latching fire & non-latching fault outputs (via expansion loom).
- Zone selectable short circuit=fire facility (pre-1980 BS, no resistors in call points).
- Up to 8 two-wire Repeaters per Main panel.
- Multi-lingual variants (subject to quantities).
- Space for 2 x 12V 7Ah VRLA batteries.
- Compatible with virtually all known conventional fire detectors including C-TEC’s ActiV range.
- Designed to comply with BS 5839-4 (this panel in not compliant with EN54-2/4 and should NOT be used in new UK or European installations).
-
₦270,000.00 -
-
C-TEC MFP 28 Zone Conventional Fire Alarm Panel Part No. FF528
-
-
- Microprocessor based design.
- Robust metal enclosure c/w lift off lid & heavy-duty base connections.
- 28 conventional Zone circuits.
- 4 conventional Sounder circuits.
- Separate indicators for open circuit, short circuit, head-out, sounder & battery/power supply faults.
- Non-latching class change sounder input, latching fire & non-latching fault outputs (via expansion loom).
- Zone selectable short circuit=fire facility (pre-1980 BS, no resistors in call points).
- Up to 8 two-wire Repeaters per Main panel.
- Multi-lingual variants (subject to quantities).
- Space for 2 x 12V 7Ah VRLA batteries.
- Compatible with virtually all known conventional fire detectors including C-TEC’s ActiV range.
- Designed to comply with BS 5839-4 (this panel in not compliant with EN54-2/4 and should NOT be used in new UK or European installations).
-
₦379,000.00 -
-
C-TEC MFP 24 Zone Conventional Fire Alarm Panel (expandable to 28 zones) Part No. FF524
-
- Microprocessor based design.
- Robust metal enclosure c/w lift off lid & heavy-duty base connections.
- 24 conventional Zone circuits (expandable to 28).
- 4 conventional Sounder circuits.
- Separate indicators for open circuit, short circuit, head-out, sounder & battery/power supply faults.
- Non-latching class change sounder input, latching fire & non-latching fault outputs (via expansion loom).
- Zone selectable short circuit=fire facility (pre-1980 BS, no resistors in call points).
- Up to 8 two-wire Repeaters per Main panel.
- Multi-lingual variants (subject to quantities).
- Space for 2 x 12V 7Ah VRLA batteries.
- Compatible with virtually all known conventional fire detectors including C-TEC’s ActiV range.
- Designed to comply with BS 5839-4 (this panel in not compliant with EN54-2/4 and should NOT be used in new UK or European installations).
₦339,000.00 -
-
C-TEC FP 8 Zone Conventional Fire Alarm Panel (expandable to 14 zones) Part No. FF388-2
-
-
-
- DESCRIPTION
- Installer-friendly design
- Robust metal enclosure c/w lift off lid & heavy-duty base connections.
- 12 conventional Zone circuits (expandable to 14).
- Two conventional Sounder circuits.
- Separate indicators for open & short circuit fault, sounder fault and battery/power supply fault.
- Non-latching class change sounder output, latching fire & non-latching fault outputs (via expansion loom).
- Short circuit=fire facility (pre-1980 BS, no resistors in call points, selectable on a zone by zone basis).
- Ancillary connections for repeaters & other system add-ons including fault relay modules, fire relay modules, sounder delay relay modules, sounder extender kits, etc).
- Multi-lingual variants (subject to quantities).
- Space for 2 x 12V 7Ah VRLA batteries.
- Compatible with virtually all known conventional fire detectors including C-TEC’s ActiV range.
- Designed to comply with BS 5839-4 (this panel in not compliant with EN54-2/4 and should NOT be used in new UK or European installations).
-
-
₦160,000.00 -
-
C-TEC FP 14 Zone Conventional Fire Alarm Panel Part No. FF394-2
-
-
-
-
- DESCRIPTION
- Installer-friendly design.
- Robust metal enclosure c/w lift off lid & heavy-duty base connections.
- 14 conventional Zone circuits.
- Two conventional Sounder circuits.
- Separate indicators for open & short circuit fault, sounder fault and battery/power supply fault.
- Non-latching class change sounder output, latching fire & non-latching fault outputs (via expansion loom).
- Short circuit=fire facility (pre-1980 BS, no resistors in call points, selectable on a zone by zone basis).
- Ancillary connections for repeaters & other system add-ons including fault relay modules, fire relay modules, sounder delay relay modules, sounder extender kits, etc).
- Multi-lingual variants (subject to quantities).
- Space for 2 x 12V 7Ah VRLA batteries.
- Compatible with virtually all known conventional fire detectors including C-TEC’s ActiV range.
- Designed to comply with BS 5839-4 (this panel in not compliant with EN54-2/4 and should NOT be used in new UK or European installations).
-
-
-
₦210,000.00 -
-
C-TEC FP 4 Zone Conventional Fire Alarm Panel (expandable to 6 zones) Part No. FF384-2
-
-
-
- Installer-friendly design.
- Robust metal enclosure c/w lift off lid & heavy-duty base connections.
- Four conventional Zone circuits (expandable to 6).
- Two conventional Sounder circuits.
- Separate indicators for open & short circuit fault, sounder fault and battery/power supply fault.
- Non-latching class change sounder output, latching fire & non-latching fault outputs (via expansion loom).
- Short circuit=fire facility (pre-1980 BS, no resistors in call points, selectable on a zone by zone basis).
- Ancillary connections for repeaters & other system add-ons including fault relay modules, fire relay modules, sounder delay relay modules, sounder extender kits, etc).
- Multi-lingual variants (subject to quantities).
- Space for 2 x 12V 3.2Ah VRLA batteries.
- Compatible with virtually all known conventional fire detectors including C-TEC’s ActiV range.
- Designed to comply with BS 5839-4 (this panel in not compliant with EN54-2/4 and should NOT be used in new UK or European installations).
-
-
₦79,000.00 -
-
C-TEC FP 6 Zone Conventional Fire Alarm Panel Part No. FF386-2
-
-
- Installer-friendly design.
- Robust metal enclosure c/w lift off lid & heavy-duty base connections.
- Six conventional Zone circuits.
- Two conventional Sounder circuits.
- Separate indicators for open & short circuit fault, sounder fault and battery/power supply fault.
- Non-latching class change sounder output, latching fire & non-latching fault outputs (via expansion loom).
- Short circuit=fire facility (pre-1980 BS, no resistors in call points, selectable on a zone by zone basis).
- Ancillary connections for repeaters & other system add-ons including fault relay modules, fire relay modules, sounder delay relay modules, sounder extender kits, etc).
- Multi-lingual variants (subject to quantities).
- Space for 2 x 12V 3.2Ah VRLA batteries.
- Compatible with virtually all known conventional fire detectors including C-TEC’s ActiV range.
- Designed to comply with BS 5839-4
- Download datasheet
-
-
-
C-TEC FP 8 Zone Economy Conventional Fire Alarm Panel Part No. FF388-3
-
-
- Installer-friendly design.
- Robust metal enclosure c/w lift off lid & heavy-duty base connections.
- Eight conventional Zone circuits.
- Two conventional Sounder circuits.
- Separate indicators for open & short circuit fault, sounder fault and battery/power supply fault.
- Non-latching class change sounder output, latching fire & non-latching fault outputs (via expansion loom).
- Short circuit=fire facility (pre-1980 BS, no resistors in call points, selectable on a zone by zone basis).
- Ancillary connections for repeaters & other system add-ons including fault relay modules, fire relay modules, sounder delay relay modules, sounder extender kits, etc).
- Multi-lingual variants (subject to quantities).
- Space for 2 x 12V 3.2Ah VRLA batteries.
- Compatible with virtually all known conventional fire detectors including C-TEC’s ActiV range.
- Designed to comply with BS 5839-4 (this panel in not compliant with EN54-2/4 and should NOT be used in new UK or European installations).
-
₦120,000.00 -
-
C-TEC EFP1 Single Zone Conventional Fire Alarm Panel Part No. FF380-2
-
- Installer-friendly design.
- Robust metal enclosure with heavy-duty base connections.
- One conventional Zone circuit
- Two conventional Sounder circuits.
- Separate indicators for open & short circuit fault, sounder fault and battery/power supply fault.
- Non-latching class change sounder output, latching fire & non-latching fault outputs (via optional expansion loom).
- Short circuit=fire facility (pre-1980 BS, no resistors in call points, selectable on a zone by zone basis).
- Multi-lingual variants (subject to quantities).
- Space for 2 x 12V 2.3Ah VRLA batteries.
- Compatible with virtually all known conventional fire detectors including C-TEC’s ActiV range.
- Designed to comply with BS 5839-4 (this panel in not compliant with EN54-2/4 and should NOT be used in new UK or European installations).
₦47,000.00 -
-
C-TEC FP 2 Zone Conventional Fire Alarm Panel Part No. FF382-2
- Installer-friendly design.
- Robust metal enclosure c/w lift off lid & heavy-duty base connections.
- Two conventional Zone circuits.
- Two conventional Sounder circuits.
- Separate indicators for open & short circuit fault, sounder fault and battery/power supply fault.
- Non-latching class change sounder output, latching fire & non-latching fault outputs (via optional expansion loom).
- Short circuit=fire facility (pre-1980 BS, no resistors in call points, selectable on a zone by zone basis).
- Ancillary connections for repeaters and other system add-ons including fault relay modules, fire relay modules, sounder delay relay modules, sounder extender kits, etc).
- Multi-lingual variants (subject to quantities).
- Space for 2 x 12V 2.3Ah VRLA batteries.
- Compatible with virtually all known conventional fire detectors including C-TEC’s ActiV range.
- Designed to comply with BS 5839-4
- Download datasheet
₦78,000.00 -
C-TEC Single Gang Locking Jack Socket for BF320 Part No. BF320JP
- Can be used in conjunction with a BF320 vibrating pillow pad to warn the hearing impaired of a potential fire alarm or evacuation alert condition.
- Compatible with all C-TEC fire alarm and evacuation alert systems.
- Locking mini-XLR connector and plug arrangement helps prevent accidental pillow pad removal.
- Line monitored for disconnection via an internal 6k8Ω end of line resistor (selectable at the BF320JP).
- Selectable 6K8 (pillow pad) or 27K (jack socket) end of line monitoring options for fire alarm or evacuation alert system use.
- Can be used on systems with a 10-30V DC voltage range
- Fits on a standard UK 25mm back box.
-
C-TEC Remote LED Indicator Part No. BF318
- A high-quality remote LED indicator specifically designed for use in fire alarm systems.
- Incorporates a high intensity, wide-angle red LED which is clearly visible from the front of the plate when active.
- Ideal for indicating the activation of hidden or out of-sight fire detectors, etc.
- Includes a white ‘write on’ area allowing installers to add equipment locations.
- Fits on standard UK 16mm flush or surface mount back boxes.
- Download datasheet
-
C-TEC 24V 5A Relay On A Plate Part No. BF376
- A general purpose, double-pole, polarised 24V 5A relay designed for use in 24V fire alarm systems.
- Incorporates a high intensity LED which illuminates red when the relay is active.
- Can be connected to a suitable control panel relay output or a standard polarised fire alarm sounder circuit to operate door retaining magnets, rollershutter doors, etc.
- Can be mounted on 25mm flush or surface mount back boxes.
-
C-TEC 4 Zone Sounder Circuit Extender Kit Part No. FF502P
- Provides four extra conventional sounder circuits with open and short circuit fault monitoring.
- Compatible with most manufacturers’ fire alarm control panels.
- Supplied on a double gang plate.
- Basic connection requires four wires: 24 VDC, 0V, Sounder –Ve & Sounder +Ve.
- Sounder -Ve & Sounder +Ve can be connected at the host panel or any convenient point on a sounder circuit (DO NOT SPUR). 24 VDC and 0V can be derived from the host panel or, alternatively, from an external PSU.
- If connecting the FF502P to a C-TEC fire panel only three input control wires are required (Sounder -Ve is not required as our conventional panels have a common 0V rail).
- Fits on standard UK 25mm flush or surface mount back boxes.
-
C-TEC Conventional Sounder Isolator Controller Part No. BF365SC
- Designed to meet requirement 17.9.2c of Dutch standard NEN2575.
- BSI certified to EN54 parts 17 & 18.
- Easily interfaced to a conventional fire alarm sounder circuit.
- Allows low-cost, non-fire resistant sounder circuit cabling to be used when used in conjunction with our BF365IM Isolator Modules (subject to fire officer approval).
- Wiring must be made in a loop arrangement, beginning and ending at the controller.
- If a wiring fault should occur, the Module(s) nearest to the faulty section of cabling will, if needed, isolate this section. As the Modules are driven from each direction, any loss of cable integrity will have no effect on the functionality of the actual sounders.
- Fits on standard UK 25mm flush or surface mount back boxes
-
C-TEC Sounder Isolator Module (max. 30 per BF365SC) Part No. BF365IM
- A fault isolating module with sounder drive capability designed to meet requirement 17.9.2c of Dutch standard NEN2575.
- BSI certified to EN54 parts 17 & 18.
- Measures just 55mm x 55mm x 16mm (will fit in the base of most conventional sounders).
- Up to 30 BF365IM modules per BF365SC controller.
- Allows low-cost, non-fire resistant sounder circuit cabling to be used when used in conjunction with our BF365SC Sounder Isolator Controller (subject to fire officer approval).
- Wiring must be made in a loop arrangement, beginning and ending at the controller.
- If a wiring fault should occur, the Module(s) nearest to the faulty section of cabling will, if needed, isolate this section. As the Modules are driven from each direction, any loss of cable integrity will have no effect on the functionality of the actual sounders.