The controlling component of a fire alarm system is the addressable control panel. The panel receives data from devices that detect and report fires, monitors their operation. It allows for automatic equipment management and transfer of information needed to prepare the facility for a fire.
Any related initiating device, notification appliance, control, transmitter, or relay may receive electrical energy from the panel.
One or more Signaling Line Circuits (SLC loops) ranging from one to thirty are used in an addressable fire alarm control panel. A Signaling Line Circuit can monitor and control hundreds of devices depending on the protocol used.
Some protocols allow for the use of any combination of detectors and input/output modules. Other protocols, on the other hand, allocate 50% of channel capacity to detectors/sensors and 50% to input/output modules.
Depending on the manufacturer, each SLC polls the linked devices, which can range from a few to several hundred. Multiple Signaling Line Circuits may be present in large systems.
-
Gent S4-720 Heat Detector
-
Heat Detection:
-
Accurately detects changes in ambient temperature to identify potential fire hazards.
-
-
Fixed Temperature Sensing:
-
Triggers alarm when a specific temperature threshold is exceeded.
-
-
Rate-of-Rise Detection:
-
Detects rapid increases in temperature, indicating a fast-developing fire.
-
-
Advanced Sensor Technology:
-
Utilizes state-of-the-art thermal sensors for reliable performance.
-
-
Addressable Functionality:
-
Can be individually identified and monitored within an addressable fire system.
-
-
Easy Integration:
-
Designed for seamless compatibility with Gent Vigilon and other Gent fire alarm panels.
-
-
Status Indication LED:
-
Provides visible status feedback for testing and maintenance.
-
₦ 51,000.00₦ 52,000.00Buy nowGent S4-720 Heat Detector
₦ 51,000.00₦ 52,000.00 -
-
Gent S4-700 Detector Base
Gent S4-700 Detector Base
The S4-700 Gent Vigilon Detector Base is the common detector base for the Gent S-Quad range of analogue addressable smoke and heat detectors. This base has an attractive low profile design.
₦ 3,000.00Buy nowGent S4-700 Detector Base
₦ 3,000.00 -
Gent 34701Series T Breaker(34701)
Gent 34701 34000 Series T Breaker
The 34701 T-Breaker Unit allows a spur to be created from a Gent analogue addressable loop circuit.
₦ 70,000.00Buy nowGent 34701Series T Breaker(34701)
₦ 70,000.00 -
GENT Spares Pack for Nano(NS-SPARE)
Gent NS-SPAREÂ Spares Pack for Nano
The NS-SPARE is a Spares Pack for the Nano Panel.
-
Gent VIG-NC-V3+ Network Card V3+
Gent VIG-NC-V3+ Network Card V3+
This network card is used to allow messages of status and control data to pass between control panels and network (or terminal) nodes in a networked fire system. The card must be plugged into the backplane of each panel and node in a dedicated slot. When it is plugged into the slot P8 on the backplane the external cables must be connected to terminal block P10, which is also located on the backplane. The dual-in-line switches on the card are set to program the address number and baud rate.
₦ 206,000.00Buy nowGent VIG-NC-V3+ Network Card V3+
₦ 206,000.00 -
Gent VIG-MCC-UPGR Vigilon Main Control Card Vigilon EN
✅ Advantages of the Gent MCC Card:
-
Enhanced System Communication: Provides robust data transfer between multiple Gent fire panels for synchronized performance.
-
Effortless Integration: Connects easily into Gent’s Vigilon control panels and expands your system’s capability.
-
High Reliability: Built with advanced diagnostics and error detection to ensure uninterrupted operation.
-
Scalable Networking: Supports large, complex installations with ease – ideal for schools, hospitals, commercial buildings, and industrial sites.
-
Future-Proof: Compatible with the latest Gent fire alarm technologies for long-term use and upgrades.
₦ 1,155,000.00₦ 1,200,000.00Buy nowGent VIG-MCC-UPGR Vigilon Main Control Card Vigilon EN
₦ 1,155,000.00₦ 1,200,000.00 -
-
Gent VIG-IOC-V3+ Input/Output Card for Vigilon V3+
Gent VIG-IOC-V3+ Input/Output Card for Vigilon V3+
The VIG-IOC-V3+ is an Input/Output Card for Vigilon V3+.
₦ 1,375,000.00₦ 1,500,000.00Buy nowGent VIG-IOC-V3+ Input/Output Card for Vigilon V3+
₦ 1,375,000.00₦ 1,500,000.00 -
Gent VIG-BSKIT Conversion Kit for VIG1-24 EN 54 to BS / V3+ Functionality
Gent VIG-BSKIT Conversion Kit for VIG1-24 EN 54 to BS / V3+ Functionality
The VIG-BSKIT is a Conversion Kit for VIG1-24 EN 54 to BS / V3+ functionality
₦ 610,000.00Buy now -
Gent Replacement PSU for VIG1-72 – VS-PSU-72
Gent Replacement PSU for VIG1-72 – VS-PSU-72
The VS-PSU-72 is a replacement PSU power supply for the VIG1-72 Vigilon fire panel.
₦ 1,200,000.00Buy nowGent Replacement PSU for VIG1-72 – VS-PSU-72
₦ 1,200,000.00 -
Gent Replacement PSU for VIG1-24 – VS-PSU-24
Gent Replacement PSU for VIG1-24 – VS-PSU-24
The VS-PSU-24 is a replacement PSU for the VIG1-24 Vigilon fire panel.
-
Gent Replacement Vigilon Printer – VS-PRIN
Gent Replacement Vigilon Printer – VS-PRIN
The VS-PRIN is a replacement printer assembly for the Vigilon range of control panels. This thermal printer uses Thermal Paper Rolls.
-
Replacement Backplane PCB for Vigilon Panels (VS-BPLANE)
Gent VS-BPLANE Replacement Backplane PCB for Vigilon PanelsÂ
The VS-BPLANE is a replacement Backplane PCB designed for Vigilon Panels
₦ 1,115,000.00Buy nowReplacement Backplane PCB for Vigilon Panels (VS-BPLANE)
₦ 1,115,000.00