Addressable Interface/Module Device implements communication between fire control panels and a personal computer. Also between fire control panels in a network. In Fire Control Panels, the module is fitted.
Compatible with all intelligent control panels currently in use. Installed on a normal 35mm DIN rail or in a stand-alone enclosure. Short-circuit isolation maintains loop continuity in the event of device failure, and a tri-color LED displays local status.
Generally interface units come in 3 forms for use with addressable fire alarm systems:
- Input unit
- The output unit (either monitored or unmonitored for faults)
- Input/output unit.
Replacing and upgrading existing conventional systems with a new addressable system in stages. In physically well-defined places such as distinct machinery rooms and boiler buildings, the module allows the use of lower-cost traditional detectors.
-
Addressable input interface unit
-
Complies with EN54 Part18
-
Low profile
-
DIN rail mounted
-
Accepts normally open input circuits
-
Monitors input circuit wiring for open or short circuit faults
-
Gent Loop Powered Interfaces- Single Input(S4-34410)
Vigilon’s range of loop powered interfaces offer
a comprehensive range of connectivity options
with critical plant and other safety systems.
Vigilon can accommodate a high quantity of loop powered interface units
offering fexible range of inputs and outputs from the FD&A system from
plant control and signalling other systems in a fi re, to linking with other
emergency management systems such as sprinklers or security systems. -
GENT INTERFACE ENCLOSURE SMALL PLASTIC SURFACE MOUNT BOX (M200E-SMB)
Description
GENT INTERFACE ENCLOSURE SMALL PLASTIC SURFACE MOUNT BOX (M200E-SMB) is a housing for Vigion’s loop powered interfaces. Vigilon’s range of loop powered interfaces offer a comprehensive range of connectivity options with critical plant and other safety systems. Vigilon can accommodate a high quantity of loop powered interface units offering fexible range of inputs and outputs from the FD&A system from plant control and signalling other systems in a fi re, to linking with other emergency management systems such as sprinklers or security systems. Loop powered interfaces offer a cost effective solution with each device individually addressed increasing the overal management capability of the FD&A system.
Interfaces are either powered from the loop or require a separate mains supply. The mains power version has its own battery backup. -
Zeta ZIOU/230Â Interface Module Loop Powered (5.0A Rating)
The Mains IO Modules are fully monitored loop powered devices which permit the interfacing of third-party equipment with the Fire Alarm Control panel using normally open dry contact connections.
-
Gent Interface Programmer for S4 Interfaces on Old Systems (S4-INTERFACE-PROG)
The S4-INTERFACE-PROG kit can be used to program the S4-Interface units to simulate legacy 344XX range of interface units. This allows the S4 interface units to be used in place of old interfaces without the need to upgrade or re-commission the system.