A detection device detects smoke as an indicator of a fire. As part of a fire alarm system, commercial detection devices send a signal to a fire alarm control panel. Household smoke detectors emit audible or visual alarm from the detector itself or multiple detectors. Detection devices usually housed in a plastic enclosure shaped like a disk. About 150 millimetres (6 in) in diameter and 25 millimetres (1 in) thick, but shape and size vary.
In large commercial and industrial buildings, smoke detectors typically linked to a central fire alarm system. Domestic smoke detectors range from single battery-powered units to multiple interconnected units with backup batteries.
- You cannot add that amount of "Gent White Sounder" to the cart because there is not enough stock (0 remaining).
-
Gent Interface Programmer for S4 Interfaces on Old Systems (S4-INTERFACE-PROG)
The S4-INTERFACE-PROG kit can be used to program the S4-Interface units to simulate legacy 344XX range of interface units. This allows the S4 interface units to be used in place of old interfaces without the need to upgrade or re-commission the system.
-
ZETA PurCheck – Non-Flammable Smoke Detector Test Spray HO-30S
- The only totally non-flammable testing product available, and an alternative to SmokeCheck®
- Meets all NFPA 72 and International Fire Codes
- 100% EPA compliant with no HFCs or CFCs
- Effective: 300+ tests per can
- UL and ULC Listed
- Safe on sensors
-
ZT-20EX Zeta ATEX Approved UV/IR Flame Detector
-
- Triple IR Spectrum – for longer distance detection and high false alarm immunity
- Compact and lightweight design
- User Selectable (Senitivity/Functions)
- Multiple output options
- Relays for Alarm and Fault
- 0-20mA (stepped)
- RS-485/RS-232 spectrum monitoring
- Lower power requirement (35mA – standby / 75mA – alarm)
- Ex cable gland /2 metre cable assembled & provided for users’ easy installation
- Certifications
- ATEX approved by DNV for explosion-proof
- CE marking
- Certifications
-
-
FS20X-211-24-6: Dual IR/UV Flame Detector (Stainless Steel)
Based on the foundation of the highly successful and reliable SS4 detector, the FS20X detector represents a quantum leap
in integrating Infrared and Ultraviolet sensing technologies. The FS20X detector is a Multi-Spectrum and UV/Dual IR/VIS
and flame detector with a proven UV solar-blind sensor. FS20X delivers a faster response and fewer false alarms, performs in
a wider ambient temperature range, with a much longer detection range compared to conventional UV/IR detectors. -
Gent by Honeywell FS24X-911-24-6: QuadBand™ IR3+ Detector (Stainless Steel)
FS24X provides wideband Multi-Spectrum Triple IR (IR/IR/IR/Visible) flame detection. It is part of our FSX family of
advanced technology Electro-Optical fire detectors. Using our patented* WideBand IR™, WideBand 4.3 micron IR™, and
Visible detection technology, the FS24X sets the standard for flame detection. Sophisticated software algorithms and dual
microprocessors ensure that the FS24X has the highest fire detection performance combined with optimal false alarm
rejection.
The WideBand IR™ Infrared technology using high-speed solid-state Quantum sensors allows detection of all types of fires,
hydrocarbon and non-hydrocarbon, in all weather conditions. -
Notifier Honeywell DOM 4-24 Digital Output Module (583362.22.IPMSG)
The DOM (Digital Output Module) is the central control element of VARIODYN D1. It has interfaces to all input/output assemblies, administers, and monitors the loudspeaker circuits for voice alarm systems and electro-acoustic emergency warning system per EN 60849 and EN 50849. Large or complex system configurations can be implemented through the networking of multiple DOMs via Ethernet. The DOM offers a high level of automatic and constant monitoring as standard. All connected power amplifiers are permanently monitored by the DOM and if a power amplifier becomes faulty, it can be replaced dynamically by a backup amplifier or a backup amplifier channel. The switchover is done automatically by the DOM. The loudspeaker lines are permanently monitored for short circuit, ground fault, and failure as well as impedance deviation. Faulty loudspeaker zones are separated in a non-reacting manner. A DOM contains storage capacity for preset announcements, which can be used for alarm texts and signals (escape alarm, caution signal) and warning signals (gongs). The volume of each source and each amplifier channel can be controlled. Additional filters like parametric equalizer, high-and low pass filter are available.
-
Gent S-Cubed Voice Sounder/HP White VAD/Red Body/EP S3EP-V-VAD-HPW-R
S-Cubed offers a comprehensive range of loop powered alarm
sounders with integrated voice and EN54-23 certified visual
alarms. Combined with flexible configuration from the fire
control panels, this loop powered device can give a differentiated
combination of audible and visual alarms for alert and general
evacuation. -
Gent 805589 S-Quad Sensor Dust Cover
Gent 805589 S-Quad Sensor Dust Cover (Pack of 50)
The Gent 805589 is a detector dust cover pack which is used with the S-Quad range of analogue addressable sensors.
These covers help prevent the detectors from being contaminated with dust during building works or prior to commissioning.
-
Gent S4-FLUSH S-Quad Semi-Flush Mounting Kit
The S4-FLUSH is an S-Quad Semi-Flush Mounting Kit. This product is ideal for aesthetically sensitive areas.
-
Gent 4″ trim ring and snap-in mounting clips for IQ8Quad detector base (805574)
Snap-in mounting clips and trim ring for base installation, e.g. for installation on 4” electrical boxes.
Take note, the label plate -
Gent S-Quad Protective cage(781550)
Protective cage for detectors
Steel basket for protection from damage and also unauthorized disconnection of the detector