Conventional Fire Alarm System employs one or more initiating circuits linked to sensors wired in parallel. The number of such circuits used limits the information density. Best utilized for smaller applications, a conventional fire alarm remains a viable fire protection solution.
Conventional fire alarm system use zones. Multiple devices, both initiating and notification devices, make up a zone that connects to the main control panel. Conventional systems are analog in that they use electrical currents to communicate with the control panel.
Conventional system relies on individual circuits to communicate with the control panel. The panel’s ability to receive information limited by the number of devices it can support.
-
ZETA Base for Intrinsically Safe Flame Detector (ZIS-33)
Technical Specification
- Diameter of installation cable wires: 2mm max; n/a
- Spacing between installation holes: 140mm
- Dimensions: Ø118 x 47mm
-
Zeta Intrinsically Safe Flame Detector (ZIS-FLD)
Technical Specification
- Voltage: 12 ÷ 28 V
- Max. quiescent current: 100 μA
- Alarm current at 20 V DC: 20 mA
- Detection distance: 17m max. (2nd class of sensitivity)
- View angle: 120o
- Wave detected: UV
- Operation temperature range: from -25 oC up to +55 oC
- Relative humidity: up to 95 % at 40 oC
- Colour: Black
- Dimensions: 107 dia. x 60 mm
- Weight: 0.45kg
-
Zeta Intrinsically Safe Optical Smoke Detector (ZIS-OSD)
Technical Specification
- Voltage: 12 ÷ 28 V
- Max. monitoring mode current: ≤ 60 μA
- Alarm current: 20 mA
- Detectable test fires: TF1 to TF5 and TF8
- Operating temperature range: from -25 o C up to +55 o C
- Relative humidity: up to 95 % at 40 o C
- Colour: Black
- Dimensions with base: 115 dia. x 54 mm
- Weight: 0.15kg
-
ZETA EX-PRO | Premier EX Pro Extinguishing Panel
Why Choose the ZETA EX-PRO?
✅ Advanced Detection & Suppression – Supports up to 3 detection zones with automatic or manual extinguishing activation.
✅ User-Friendly Interface – Intuitive LCD display and straightforward controls for ease of operation and monitoring.
✅ Flexible Configuration – Compatible with a wide range of extinguishing agents, from FM200 to CO₂ and more.
✅ Built-In Event Log – Keep track of system events with an internal memory log for better diagnostics and compliance.
✅ Reliable Performance – Built to meet the latest international fire safety standards (EN12094-1).
✅ Fail-Safe Security – Multiple levels of fault monitoring and system status indicators for full control and peace of mind.
✅ Customizable Delays & Alerts – Pre-discharge warnings and programmable timers to suit your environment’s unique needs.Whether you’re securing data centers, industrial spaces, or high-risk facilities, the ZETA EX-PRO delivers unmatched safety, smart technology, and unwavering reliability.
🛡️ Premier Protection Starts Here.
₦ 450,000.00₦ 470,000.00Buy nowZETA EX-PRO | Premier EX Pro Extinguishing Panel
₦ 450,000.00₦ 470,000.00 -
ZETA ZT-CP3/WP/Y | Weatherproof Manual Release Unit (Surface Mount)
Manual call points for gas release (available in indoor or outdoor versions) and gas abort.
₦ 35,000.00Buy now -
ZETA Call Reset Key | CP3-KEY
Manual call points for gas release (available in indoor or outdoor versions) and gas abort.
-
ZETA CP3-FMB/B | Abort Call Point Flush Mount Bezel
Manual call points for gas release (available in indoor or outdoor versions) and gas abort.
-
ZETA Call Point Protective Cover | CP3-CV
- Gas release manual call point in blue housing
- Single pole changeover
-
ZETA ZT-CP3/B| Abort Call Point
- Gas release manual call point in blue housing
- Single pole changeover
-
ZETA ZT-CP3/Y Gas Extinguishing Call Point
- Gas release manual call point in yellow housing
- Single pole changeover