APOLLO AlarmSense Open Area Sounder IP65
- A powerful wall-mounting open-area Sounder/Visual Indicator suitable for use with C-TEC’s CFP AlarmSense range of 2-8 Zone Two-Wire Fire Panels.
- IP65 rated.
- Up to 99dB(A) sound output at 1m.
- Ultra-bright red LED.
- Device locking facility.
- Max. five Open-Area Alarm Devices per AlarmSense zone.
AlarmSense Open Area Sounder IP65
 55000-018APO
- A powerful wall-mounting open-area Sounder suitable for use with C-TEC’s CFP AlarmSense range of 2-8 Zone Two-Wire Fire Panels.
- IP65 rated.
- Up to 99dB(A) sound output at 1m.
- Device locking facility.
- Max. five Open-Area Alarm Devices per AlarmSense zone.
Supply wiring | 2-wire monitored, polarity insensitive. |
Supply/operating voltage | 18-33VDC (sounders active); Less than 15VDC (sounders off). |
Quiescent current | 100µA @ 12VDC. (Max. surge current 200µA). |
Nominal SPL (Sound Pressure Level) | Up to 99dB(A) @ 1m. Note the tone frequency incorporated into this device is the Apollo Evacuate tone (840Hz for 0.5s and 546Hz for 0.5s). |
Alarm current | 17.5mA @ 24VDC (nominal). |
Product dimensions (mm) | 97.5mm diameter x 104mm deep. |
Construction & finish | TBC. |
IP Rating | IP65 |
Weight | 225g. |
Operating conditions/temperature | TBC. |
Dimensions | 4.0 × 11.5 × 4.0 cm |
---|
Related products
-
C-TEC ActiV Conventional Hi-Output W-2.75-9 Wall VAD c/w 100dB(A) Sounder (shallow base) Part No. BF433C/CC/SR
Read more- Third-party certified to EN54-3 (Sounders) and EN54-23 (VADs).
- Provides ‘W-2.75-9’ rated light distribution when wall mounted (min. 0.4 lux over a 2.75Â x 9m cuboid area). Also rated as a W-4-4 VAD.
- Impressive 100dB(A) sound output @ 1m.
- Includes 31 selectable primary tones and an optional secondary tone.
- Two volume levels (high and low)
- Three selectable VAD flash rates (0.5Hz, 1Hz, OFF)
- Alarm Current at 30Vdc =Â 12.2mA (0.5Hz) or 19.5mA (1Hz)
- Alarm Current at 18Vdc =Â 14.5mA (0.5Hz) or 25mA (1Hz)
- IP21C rated.
- Manufactured in the UK by C-TEC.
-
Zeta Fyreye MKII Diode Base
₦1,500.00Add to cartDESCRIPTION
Fyreye MKII Diode Base
Low profile or deep diode mounting base for the Fyreye MKII range of conventional detectors.
-
APOLLO AlarmSense Base Sounder/Visual Indicator Part No. 45681-509APO
Read more- Will accept any AlarmSense fire detector to provide fire detection and an audible AND visual alarm warning signal at the same point.
- 70d-87dB(A) sound output (visual indicator activates with sounder).
- Certified to EN54-3Â by UL International (UK) Limited.
- Suitable for use with C-TEC’s CFP AlarmSense range of 2-8 Zone Two-Wire Fire Panels.
- AlarmSense priority/non priority signal recognition
- Detects the removal of a detector head and reports a fault
- Continues to work during unauthorised removal of detector.
- High and low volume ranges.
- Red and white caps available for stand-alone use.
- Can also be purchased as part of a detector/sounder visual indicator base combination (see Combination AlarmSense Devices section below).
-
Zeta ID2/4/M Infinity ID2 Intelligent 2 Wire 4 Zone Fire Panel in Metal Enclosure
Read moreDescription
Zeta Alarm Systems is proud to introduce the most
advanced
2 wire system on the market. We can now
provide
a system that gives all of the benefits associated
with
a ‘2 Wire’ installation (less cable, quicker installation,
cost savings on labour/product) and has the facility to
‘I.D.’ the devices.
The system is built on the proven communication protocol
developed by Zeta Alarm Systems and shares the same
platform as our largest, most powerful system.
The ID2 can be used for new installations, as
a retrofit for any conventional system or as a replacement for
existing
2 wire systems when the extra features are
deemed to be desirable/necessary. This is possible
because the ID2 devices sit on radial circuits, thus
making it easy to ‘upgrade’
a system with the facility to
I.D. devices without the need to re-wire.
Technical
Popular Tags
Best offers
Join Risk Free
30 days refund
100% Safe
Secure Shopping
24x7 Support
Online 24 hours
Best Offers
Grab Now
Free Shiping
On all order over
Know Us
Safetech.hub is the newest online platform envisioned to provide 24/7 online platform for integrators, installers, and end users of Extra Low Voltage (ELV) systems in Nigeria
Read More
Reviews
There are no reviews yet.