Category
- Burglary Alarm System
- Cable
- Closed Circuit Television System (CCTV)
- Fire Equipment
- Pepper Spray Vault/ATM Protection System
- Personal Security
- Physical Access Control
Popular
- Gent Fire Alarm System Set of Keys for Key Switch Interface and MCP
- Gent Fire Alarm Vigilon Manual Call Point with Glass Element and Protective Cover (Excludes Back Box)
- Cutting-Edge Velocity Zeta Aspiration Smoke Detection Fire Alarm Panel
-
GENT ADDRESSABLE FIRE ALARM 1 TO 6 LOOP CONTROL PANEL
₦6,250,000.00Original price was: ₦6,250,000.00.₦6,170,000.00Current price is: ₦6,170,000.00. -
TEXECOM VERITAS IMPAQ E BURGLAR ALARM VIBRATION DETECTOR- WHITE
₦22,000.00Original price was: ₦22,000.00.₦18,500.00Current price is: ₦18,500.00. -
PAXTON ACCESS CONTROL NET2 PLUS 1 DOOR CONTROLLER – POE+, PLASTIC CABINET
₦462,000.00Original price was: ₦462,000.00.₦458,000.00Current price is: ₦458,000.00. -
Concept Handheld Metal Detector with Vibration Function
₦20,000.00Original price was: ₦20,000.00.₦19,000.00Current price is: ₦19,000.00. -
Fisher Research Labs M-scope Walk-Through Metal Detector
₦4,600,000.00Original price was: ₦4,600,000.00.₦4,500,000.00Current price is: ₦4,500,000.00. -
CONCEPT (Burglar Alarm) WIRELESS SIGNAL REPEATER
₦23,500.00Original price was: ₦23,500.00.₦21,500.00Current price is: ₦21,500.00. -
CONCEPT (Fire Alarm) TUYA WIFI SMOKE DETECTOR
₦13,000.00Original price was: ₦13,000.00.₦11,000.00Current price is: ₦11,000.00.
Apollo (Fire Alarm) AlarmSense Optical Smoke Detector
₦17,000.00 Original price was: ₦17,000.00.₦14,000.00Current price is: ₦14,000.00.
AlarmSense Optical Smoke Detector
55000-390APO
- A high quality optical detector.
- Suitable for use with C-TEC’s CFP AlarmSense range of 2-8 Zone Two-Wire Fire Panels.
- Housed in a pure white polycarbonate moulding.
- Fitted with two alarm LEDs to allow 360º visibility.
- Third-party certified to EN54-7 by UL International (UK) Limited.
- 9-33V DC operating voltage.
- Requires a 45681-244APO AlarmSense base.
- Can also be purchased as part of a detector/sounder or detector/sounder visual indicator base combination (see Combination AlarmSense Devices section below)
Approvals/certifications | Certified to EN54-7 by UL International (UK) Limited. |
Application/operation | Generates an alarm condition when it detects a pre-set threshold of smoke penetration into the smoke chamber. |
Supply wiring | 2-wire monitored, polarity insensitive. |
Supply/operating voltage | 9 to 33V DC. |
Quiescent current | 50µA @ 15 VDC. |
Alarm voltage | 9-33V DC. |
Alarm current | 1.5mA @ 2-8.5V; 25 +/- 2mA @ 10.5-15V; 1.5AmA @ 18-24V; 2mA @ 33V. |
Alarm reset voltage | 2V max (1 second alarm reset time). |
Product dimensions (mm) | 100mm diameter x 42m deep (detector only); 100mm diameter x 50mm deep (detector in base). |
Construction & finish | White polycarbonate. |
IP Rating | TBC. |
Weight | 100g. |
Related products
-
Out of Stock
Apollo Addressable Fire Alarm Series 65A Base – High-Performance Detector Mounting Solution
Read moreTwo-wire base
• Detector locking mechanism
• One-way fit
• Easy to wire
• Contains a ground wire terminal
• Contains no electric parts -
Out of Stock
Gent Fire Alarm G017-01 Weatherproof Manual Call Point W1A-R470SF
Read moreManual call points from Honeywell Gent are easy and safe to operate, with no hammer required. Fully compliant with EN 54-11, each point is manufactured from ABS and both have a break glass and resettable element. For areas susceptible to inadvertent operation – such as sports halls – a stronger, clear polycarbonate cover version is available.
-
Out of Stock
APOLLO Addressable Fire ALarm ISOLATOR
Read moreThe Isolator is placed at intervals on the loop and ensures that, in the case of a short circuit, only the section between the isolators will be affected. When the short circuit is removed, the isolators automatically restore power and data to the isolated section.
- Detects wiring short-circuits using patented technology
- Minimizes disruption from short-circuits
- Automatic de-isolation on short-circuit removal
- Up to 20 devices may be installed between isolators
-
Out of Stock
Gent Fire Alarm G017-01 Flush MCP 470 Ohms M1A-R470FG
Read moreManual call points from Honeywell Gent are easy and safe to operate, with no hammer required. Fully compliant with EN 54-11, each point is manufactured from ABS and both have a break glass and resettable element. For areas susceptible to inadvertent operation – such as sports halls – a stronger, clear polycarbonate cover version is available.
Best offers
Join Risk Free
30 days refund
100% Safe
Secure Shopping
24x7 Support
Online 24 hours
Best Offers
Grab Now
Safe and Secured Payment
On all order over
Know Us
Safetech.hub is the newest online platform envisioned to provide 24/7 online platform for integrators, installers, and end users of Extra Low Voltage (ELV) systems in Nigeria
Read More
Reviews
There are no reviews yet.