General Description
The EDB01 Reflective Beam Smoke Detector is a single unit comprising a transmitter and a receiver. The transmitter projects a cone shaped beam of modulated infra-red light to prisms. An alarm condition will be determined when the signal is analyzed to reach up to the settings of retention of smoke (4 sensitivity levels).
In addition, the unit is designed to be wall-mounted so that the beam will project approximately 0.3m to 0.6m below and parallel to the ceiling and the maximum lateral range is 7.5m either side of the beam. The coverage ranges of distance are from 10m to 100m.
Characteristics
- EN54-12 Approval.
- Easy installation.
- Laser-aid alignment.
- Operating range: 10m to 100m.
- Four sensitivity levels 18%, 25%, 35%, and 50%.
- Latching / Non-Latching threshold setting.
- Lower potential voltage & current consumption.
- Self-alignment & Automatic contamination compensation.
- Bluetooth App operation on smartphone & tablet, display smoke value, temperature and 3 mode status (Supervising, Alarm, Fault ).
Model | EDB01 |
Operating Voltage | 12-30V DC |
Standby Current | 3~20mA |
Alarm Current | 20~40mA |
Alarm Output | 1A @30V DC (COM/NO) |
Fault Output | 1A @30V DC (COM/NC) |
Sensitivity Level | 18% (0.75-0.96dB) 10 ~ 20M |
Sensitivity Level | 25% (1dB) 20 ~ 50M |
Sensitivity Level | 35% (1.07dB) 50 ~ 70M |
Sensitivity Level | 50% (1.24-1.59dB) 70 ~ 100M |
Operating Range | 10m to 50m use 1 prism, 50m to 100m use 4 prisms |
Angular Tolerance | Detector: ±0.5˚ / Prism: ±5.0˚ |
Ambient Temperature | -10℃ ~ +55℃ |
Material | ABS Plastic |
Color | White |
Weight | 350g (Detector) |
Related products
-
Zeta ID2/8/M Infinity ID2 Intelligent 2 Wire 8 Zone Fire Panel in Metal Enclosure
Read moreDESCRIPTION
Zeta Alarm Systems is proud to introduce the most advanced 2 wire system on the market. We can now provide a system that gives all of the benefits associated with a ‘2 Wire’ installation (less cable, quicker installation, cost savings on labour/product) and has the facility to ‘I.D.’ the devices.
The system is built on the proven communication protocol developed by Zeta Alarm Systems and shares the same platform as our largest, most powerful system.
The ID2 can be used for new installations, as a retrofit for any conventional system or as a replacement for existing 2 wire systems when the extra features are deemed to be desirable/necessary. This is possible because the ID2 devices sit on radial circuits, thus making it easy to ‘upgrade’ a system with the facility to I.D. devices without the need to re-wire.
-
EXD SOUNDER TCB-0017
Read moreThe EXD Sounder has been approved for use in potentially explosive atmospheres and very harsh environmental conditions.
The unit incorporates a three stage alarm option with sixty three tones to choose from which includes four tones that can be recorded or customised by the installer. All tones can be pre-set during installation.
The units also have the ability to be fitted with a telephone initiation function and can be used as the second ring output indicator for telephones when installed in very noisy environments.
The design allows for termination inside the enclosure. The sounder is supplied with a mounting bracket as standard. -
Texecom EXD Buzzer TCA-0005
Read moreEXD Buzzer
The Exd Buzzer is an explosion proof buzzer designed
for use in hazardous areas where a distinctive signal is
required. Certified to ATEX II 2G Exd e IIC T6, it is suitable for
use in Zone 1 and Zone 2 areas.
Producing a tone with low frequency, it cuts through
background noise more effectively than many other
devices of a similar output.
Mounted in a rugged reinforced polyester case and
weatherproof to IP66, it is suitable for use in the most
arduous conditions. -
Gent Flush Manual Call Point (XENS-850) 470 Ohms Glass
Read moreGent XENS-850 Flush Manual Call Point 470 Ohms Glass
Gent Flush Manual Call Point are designed to provide a manual alarm interface to conventional fire alarm control panels. All call points are supplied in the standard red colour and are available in semi-flush mounting or surface mounting options. The manual call points are all with a 470 Ohm resistor and Normally Open contact, complete with glass.
Both break glass, and resettable operating elements can be used in the standard unit by a yellow strip on the element which becomes visible when activated.
With the addition of a hinged transparent cover the element may be protected against accidental operation.
A specialist test key may be inserted into the bottom of the unit to lower the glass and release the micro-switch and thus a full functional test is achieved.
Popular Tags
Best offers
Join Risk Free
30 days refund
100% Safe
Secure Shopping
24x7 Support
Online 24 hours
Best Offers
Grab Now
Free Shiping
On all order over
Know Us
Safetech.hub is the newest online platform envisioned to provide 24/7 online platform for integrators, installers, and end users of Extra Low Voltage (ELV) systems in Nigeria
Read More
Reviews
There are no reviews yet.