Category
- Uncategorized
- Access Control and Time Attendance System
- Accessories
- Addressable base
- Audio
- Cable
- Call Point
- Cameras
- Closed Circuit Television System (CCTV)
- Computer & Laptop
- Door controller
- Fire Alarm System
- Home Appliances
- Manual Callpoints
- Metal Detector
- Naso mask
- New Arrival
- Night Vision
- On Sale
- Security Alarm System
Popular
-
C-Tec FP 8 Zone Conventional Fire Alarm Panel-Ff388-2
₦125,000.00₦120,000.00 -
SOCA SL-130 Dead Bolt Lock ( All purpose type )
₦15,000.00₦13,000.00 -
SOCA SL-100D Dead Bolt Lock ( for automatic door)
₦18,000.00₦15,000.00 - SOCA SL 100A Dead Bolt ₦15,000.00
- Soca SD-30 Armored Door Loop
Tag Clouds
C-TEC EP203 Automatic Extinguisher Panel Part No. EP203
₦169,000.00
Technical Specifications
Approvals/certifications Certified to EN12094-1 and EN54-2 & 4 by the LPCB.
Mains supply 230V 50/60Hz.
Mains rated current 810mA max.
Internal power supply 19V-28.5V (27V nominal). Ripple 7V maximum (battery fault).
Total output current limited to 1.5A @ 230Vac continuous, 3A peak (ImaxA eq 800mA).
Quiescent current 40mA (on mains fail). Zone quiescent 2mA max.
Max battery size and type 2 x 12V 7Ah VRLA connected in series.
No. of detector zone circuits 3 @ 19-28Vdc (Max. length per circuit is 250m).
Max. devices per detector zone 20 detectors (or 32 detectors/manual call points combined).
No. of conventional sounder circuits 3 (two x 1st stage; one x 2nd stage). Max. length per circuit is 50m).
EOL resistor value 6800 5% Tol. 0/25W (blue, grey, red, gold).
Max. sounder output current 3 x 200mA.
Auxiliary relays Six: (1) Fire; (2) Local Fire; (3) Extract Fan; (4) 1st Stage; (5) 2nd Stage; (6) Fault. Volt free single pole
changeover. Max. switch current 1A; Max. switch voltage 30Vdc. Five additional relays available via
EP212 relay card.
Other outputs Extinguishant release (21-28Vdc, rated at 1A for 5 mins). Programmable to delay by 0-60 seconds; to
be active for 1-300 seconds and to flood for 60-1800 seconds.
Auxiliary inputs Six: (1) Manual Release; (2) Flow Switch; (3) Low Pressure; (4) Mode; (5) Hold; (6) Abort. 8K-2K normal;
1.8K-200 active; 150-0 short circuit. EOL value: 6K8 +/-5%, 0.25W.
Indicators Multiple indicators are provided – refer to the EP203 instructions for details.
Controls Extinguishant release (housed in yellow casing); Accessed keyswitch; Operation keyswitch (Manual
only or Manual & Auto); Buttons for Menu; Silence internal sounder; reset panel; silence/resound
sounders and scrolling.
Expansion connections Yes – for up to 8 x Remote status units (2 wire RS485 + 2 wire power) and/or up to 8 x Ecomomy
status units (2 wire power + 2 wire mode select).
Product dimensions (mm) 439 W x 276 H x 70 D mm (back box); 467 W x 293 H x 29 D mm (lid).
Construction & finish Metal back box; metal chassis’ plastic lid.
IP Rating IP30.
Weight 4.2kg (without batteries).
Operating conditions/temperature -5°C to +40°C. Max relative humidity: 95%
LPCB certified to EN 12094-1 (the European standard for Fixed Firefighting Systems – Components for Gas Extinguishing Systems) and EN54-2/4, the EP203 three zone automatic extinguisher panel epitomises quality, durability and reliability.
Specifically designed for use in areas housing expensive, dangerous or irreplaceable items of equipment, it features an intuitive 128 x 64 pixel display that gives clear and concise feedback to the user, installer and commissioning engineer. It has six monitored inputs (including hold & abort), a time stamped log, adjustable flood times and volt-free changeover relays for fire, local fire, 1st stage active, 2nd stage active, extractor fan and fault.
All of the panel’s electronics – apart from its powerful 3A EN54-4 switch mode PSU – are mounted on a detachable metal bridge plate for ease of installation. A wide range of ancillaries are also available including remote status units, hold-off & abort buttons, line terminators and relay boards.
Weight | 4.2 kg |
---|---|
Dimensions | 276 × 439 × 70 cm |
Related products
-
Gent Interface Programmer for S4 Interfaces on Old Systems (S4-INTERFACE-PROG)
Read moreThe S4-INTERFACE-PROG kit can be used to program the S4-Interface units to simulate legacy 344XX range of interface units. This allows the S4 interface units to be used in place of old interfaces without the need to upgrade or re-commission the system.
-
Texecom EXD Buzzer TCA-0005
Read moreEXD Buzzer
The Exd Buzzer is an explosion proof buzzer designed
for use in hazardous areas where a distinctive signal is
required. Certified to ATEX II 2G Exd e IIC T6, it is suitable for
use in Zone 1 and Zone 2 areas.
Producing a tone with low frequency, it cuts through
background noise more effectively than many other
devices of a similar output.
Mounted in a rugged reinforced polyester case and
weatherproof to IP66, it is suitable for use in the most
arduous conditions. -
Gent Vigilon VIG-IOC-DOM Input/Output Domain Card
₦1,315,000.00Add to cartGent Vigilon Input / Output Domain Card – VIG-IOC-DOM
The VIG-IOC-DOM is a Vigilon EN54 Input Output Domain Card for Vigilon Control Panels.
Key Features
- EN54
-
Solo 823 Smoke & Cordless Heat Detector Test Set 9.3 Metres
₦2,500,000.00₦2,261,000.00Add to cartSolo 823 Smoke & Cordless Heat Detector Test Set 9.3 metres Solo equipment is available in a number of conveniently arranged kits. Whether your need is for a simple starter kit, a universal smoke testing kit, or an all encompassing kit including a heat detector tester, there is one available. Larger kits are supplied with …
Solo 823 Smoke & Cordless Heat Detector Test Set 9.3 MetresRead More
Popular Tags
Best offers
Join Risk Free
30 days refund
100% Safe
Secure Shopping
24x7 Support
Online 24 hours
Best Offers
Grab Now
Free Shiping
On all order over
Know Us
Safetech.hub is the newest online platform envisioned to provide 24/7 online platform for integrators, installers, and end users of Extra Low Voltage (ELV) systems in Nigeria
Read More
Reviews
There are no reviews yet.