2 × ₦ 92,610.00
-
2 × ₦ 140,175.00
-
2 × ₦ 21,000.00
-
2 × ₦ 6,300.00
-
2 × ₦ 5,460.00
-
2 × ₦ 665,175.00
-
2 × ₦ 651,000.00
-
2 × ₦ 40,000.00
-
4 × ₦ 362,250.00
-
2 × ₦ 53,550.00
-
2 × ₦ 234,150.00
-
7 × ₦ 11,025.00
-
2 × ₦ 18,900.00
-
2 × ₦ 248,850.00
-
4 × ₦ 147,000.00
-
6 × ₦ 510,825.00
-
2 × ₦ 158,550.00
-
2 × ₦ 65,000.00
-
5 × ₦ 178,500.00
-
4 × ₦ 2,211,300.00
-
6 × ₦ 2,102,100.00
-
2 × ₦ 8,925.00
-
2 × ₦ 1,506,750.00
-
2 × ₦ 61,950.00
-
1 × ₦ 122,850.00
-
4 × ₦ 47,000.00
-
2 × ₦ 332,850.00
-
2 × ₦ 78,750.00
-
2 × ₦ 23,000.00
-
2 × ₦ 471,450.00
-
2 × ₦ 1,185,450.00
-
2 × ₦ 67,500.00
-
2 × ₦ 208,950.00
-
2 × ₦ 210,000.00
-
2 × ₦ 1,917,000.00
-
2 × ₦ 1,890,000.00
-
2 × ₦ 10,000.00
-
2 × ₦ 69,500.00
-
1 × ₦ 45,000.00
-
2 × ₦ 2,853,375.00
-
2 × ₦ 199,500.00
-
2 × ₦ 255,000.00
-
2 × ₦ 17,325.00
-
2 × ₦ 20,475.00
-
2 × ₦ 147,525.00
-
2 × ₦ 1,285,000.00
Zeta Infinity 8 Conventional 2 Zone Fire Alarm Panel IN2
₦ 362,775.00₦ 370,000.00 (-2%)
Features
Access via password – removes problem of lost keys
One man test facility
Disablement facility for zones & sounders
Space for up to 3Ah batteries
Sounder delay option
4 sounder circuits (IN4, IN6 & IN8)
Sounder circuits 3 and/or 4 can be configured as Aux
24V supplies
Meets all requirements of latest EN54 part 2 and
part4
The Infinity 8 control panel is housed in the
most attractive, modern designed, flame
retardent ABS enclosure, utilising a switch
mode power supply. It has a fully removable
front cover which improves ease of access for
cable installations.
The Infinity 8 panel can also be ordered with a metal back
box facilitating upto 7ah batteries to fit within the panel
housing.
Features
Access via password – removes problem of lost keys
One man test facility
Disablement facility for zones & sounders
Space for up to 3Ah batteries
Sounder delay option
4 sounder circuits (IN4, IN6 & IN8)
Sounder circuits 3 and/or 4 can be configured as Aux
24V supplies
Meets all requirements of latest EN54 part 2 and
part4
Technical Specification
Model IN1 IN2 IN4 IN6 IN8
Part No 37-650 37-651 37-652 37-653 37-654
Mains Voltage 230V AC +10% / -15% @ 50/60 Hz
System Voltage 24V DC (Nominal)
Zone Voltage 21V DC (Nominal)
Sounder Alarm Output 2 x 150mA @ 24V DC 4 x 150mA @ 24V DC
Fault Relay 1 x Volt Free Relay, SELV @ 1A Max
Fault Relay 1 x Volt Free Relay, SELV @ 1A Max
Zone Capacity 32 devices per zone
Remote sounder operation Via N/O contact connected to Class Change
Sounder Activation Delay 0 to 10 minutes in 1 minute increments
Zone End of line 1N4002 Diode (Cathode Stripe to Zone +ve)
Sounder End of Line 10K resistor
Charger Voltage 27.6V
Battery cut off Battery voltage less than 20V
Battery Internal Resistance limit 0.9 ohm
Enclosure size 371 x 302 x 93 (mm)
Weight 3 kg (Excluding Batteries)
Maximum battery space 2 x 3.4 Ah, 12 Vdc sealed lead acid
Additional information
| Weight | 3 kg |
|---|---|
| Dimensions | 37.1 × 30.2 × 9.3 cm |