Category
- Uncategorized
- Access Control and Time Attendance System
- Accessories
- Addressable base
- Audio
- Cable
- Call Point
- Cameras
- Closed Circuit Television System (CCTV)
- Computer & Laptop
- Door controller
- Fire Alarm System
- Home Appliances
- Manual Callpoints
- Metal Detector
- Naso mask
- New Arrival
- Night Vision
- On Sale
- Security Alarm System
Popular
-
C-Tec FP 8 Zone Conventional Fire Alarm Panel-Ff388-2
₦125,000.00₦120,000.00 -
SOCA SL-130 Dead Bolt Lock ( All purpose type )
₦15,000.00₦13,000.00 -
SOCA SL-100D Dead Bolt Lock ( for automatic door)
₦18,000.00₦15,000.00 - SOCA SL 100A Dead Bolt ₦15,000.00
- Soca SD-30 Armored Door Loop
Tag Clouds
HORING LIH AH Q01 EN Photoelectric Smoke Detector
₦13,000.00 ₦10,000.00
- EN54-7 Approval.
- The standard detector is 2-wire or 3-wire with base.
- For 4-wire type just add one relay output module on 3-wire base. Simple and easy module placement enables wider application.
- Dual LEDs for 360-degree visibility. Bi-color LED, Stand-by Status: Green; Alarm Status: Red.
- Detector is made of high endurance, solid and colorfast Fire-proof plastic.
- Non-loosening screws on base terminal for easy installation.
- Detector has passed strict EMC test, which greatly eliminates false alarms caused by interference from nearby sources.
Characteristics
-
- EN54-7 Approval.
- The standard detector is 2-wire or 3-wire with base.
- For 4-wire type just add one relay output module on 3-wire base. Simple and easy module placement enables wider application.
- Dual LEDs for 360-degree visibility. Bi-color LED, Stand-by Status: Green; Alarm Status: Red.
- Detector is made of high endurance, solid and colorfast Fire-proof plastic.
- Non-loosening screws on base terminal for easy installation.
- Detector has passed strict EMC test, which greatly eliminates false alarms caused by interference from nearby sources.
Specification
Q01 Conventional Photoelectric Smoke Detector
Model | Q01-2 | Q01-3 | Q01-4 |
Alarm Contact | N/A | N/A | 0.8A @30V DC, 0.4A @125V AC |
Voltage Range | 12 ~ 30V DC | ||
Alarm Current@24V DC 470Ω | 40mA | 40mA | 45mA |
Standby Current@24V DC 470Ω | under 75μA | ||
Sensitivity Setting | Comply to EN54 | ||
Ambient Temperature | -10℃ ~ +55℃ | ||
Material | Fire-proof plastic | ||
Dimensions | 102mm(Dia.) x 48mm(H) | ||
Weight | Â 130g | Â 130g | Â 145g |
Color | White |
Effective Alert Area
Building Height | Area Covered |
Under 4M | 150 M2 |
4 ~ 20M | 75 M2 |
Order Information
Q01-2 | 2-wire |
Q01-3 | 3-wire with remote indicator output |
Q01-4 | 4-wire with relay output |
Related products
-
C-TEC ActiV Relay Base with Diode Part No. C4408DR
Read more-
- Compatible with C-TEC’s entire range of ActiV fire detectors.
- Includes a 1A @ 24 VDC relay controlled by detector’s remote LED output.
- Ideal for switching CCTV, security and door retaining systems.
- Third-party certified to the relevant parts of EN54 in conjunction with our ActiV detectors.
- Easy to fit with lots of working space.
- Can be ceiling mounted in any orientation due to the true 360° degree viewing angle of the LED indicator strips on all ActiV detectors.
- Integrated detector/base locking mechanism, head removal tool and ID tag.
- Simple ‘click and twist’ design.
- Remote LED terminals for the optional connection to a BF318 Remote indicator.
- C4408R non-diode relay base also available for use on systems that do not require head out monitoring.
-
-
Texecom EXD Buzzer TCA-0005
Read moreEXD Buzzer
The Exd Buzzer is an explosion proof buzzer designed
for use in hazardous areas where a distinctive signal is
required. Certified to ATEX II 2G Exd e IIC T6, it is suitable for
use in Zone 1 and Zone 2 areas.
Producing a tone with low frequency, it cuts through
background noise more effectively than many other
devices of a similar output.
Mounted in a rugged reinforced polyester case and
weatherproof to IP66, it is suitable for use in the most
arduous conditions. -
Gent 4 ZONE CONVENTIONAL PANEL, EN54 LESS BATTERIES (13270-04LB)
₦259,000.00₦235,500.00Add to cartDESCRIPTION
Gent 13270-04LB 4 Zone Conventional Xenex Fire Panel
BSI approved to EN54: Parts 2 & 4, the Xenex control panel can be used on installations meeting BS 5839:Part1. Control panel options for 2-8 zones can be specified.
Designed to simplify system installation, each Xenex panel contains an integral power supply and battery support to drive up to 8 alarm sounder circuits, 2 auxiliary relay contacts, a zone disablement facility and also one-man test and commissioning features.
-
Zeta Fyreye MkII Conventional Heat Detectors MKII-HF/CS90
₦9,500.00Add to cartDESCRIPTION
The Fyreye Rate of Rise heat detectors (MKII-HFCS90) use a thermistor arrangement to sense a quick rise in
temperature and also a final threshold temperature of 90°C. The Fyreye fixed heat detector (MKII-HF/CS90) has a single thermistor arrangement that gives an alarm at a temperature of 90°C.
There are 4 types of mounting base available; standard or deep and with or without diode.
Popular Tags
Best offers
Join Risk Free
30 days refund
100% Safe
Secure Shopping
24x7 Support
Online 24 hours
Best Offers
Grab Now
Free Shiping
On all order over
Know Us
Safetech.hub is the newest online platform envisioned to provide 24/7 online platform for integrators, installers, and end users of Extra Low Voltage (ELV) systems in Nigeria
Read More
Reviews
There are no reviews yet.