Zeta CP4 Conventional Manual Call Point, Red ZT-CP4
₦8,000.00
DESCRIPTION
Zeta Conventional Manual Call Point
The ZT-CP4 is a resettable manual call point
with unique and innovative features. It has
been designed to obtain maximum visibility, high
reliability in operation and pleasant aesthetical
appearance.
When the resettable element is pressed the
spring mechanism mimics the feel of a break
glass and the resettable element goes back.
A completely new action system gives high
performance and guarantees the alarm detection
in every condition.
A reflective polyester flag appears in the bottom of
the operating face, providing the highest levels of
visibility for the user. At the heart of the call point a
spring free mechanism is used to operate the flag
and the switch via a patented design. This allows
long life and trouble free operation.
Zeta Conventional Manual Call Point
The ZT-CP4 is a resettable manual call point
with unique and innovative features. It has
been designed to obtain maximum visibility, high
reliability in operation and pleasant aesthetical
appearance.
When the resettable element is pressed the
spring mechanism mimics the feel of a break
glass and the resettable element goes back.
A completely new action system gives high
performance and guarantees the alarm detection
in every condition.
A reflective polyester flag appears in the bottom of
the operating face, providing the highest levels of
visibility for the user. At the heart of the call point a
spring free mechanism is used to operate the flag
and the switch via a patented design. This allows
long life and trouble free operation.
Features
- EN54-11 approved.
- Very high visibility of the alarm condition.
- New efficient and reliable mechanism.
- High impact resistant ABS glass fiber material Fully patented.
- Quick and Easy Installation.
Technical Specification
- Maximum Voltage : 30V
- Minimum Voltage :
- Indoor (ZT-CP4 & ZT-CP4/F) :
- 4.5V if LED with R1 is chosen
- 6.0V if LED with R2 is chosen
- Outdoor (ZT-CP4/WP) :
- 5.0V if LED with R1 is chosen
- 6.0V if LED with R2 is chosen
- Indoor (ZT-CP4 & ZT-CP4/F) :
- Current Rating (non-operated)Â : 0mA
- Current Rating (operated)Â :
- Indoor (ZT-CP4 & ZT-CP4/F) :
- 18 mA @ 12V – R1
- 13 mA @ 12V – R2
- 45 mA @ 24V – R1
- 31 mA @ 24V – R2
- Outdoor (ZT-CP4/WP) :
- 19 mA @ 12V – R1
- 13 mA @ 12V – R2
- 45 mA @ 24V – R1
- 31 mA @ 24V – R2
- Indoor (ZT-CP4 & ZT-CP4/F) :
- Cable Termination : 0.5 – 2.5 mm2
- Operating Temperature : -30 / +70°C
- Humidity : 0 – 95%
- IP Rating :
- Indoor (ZT-CP4 & ZT-CP4/F) : IP42
- Outdoor (ZT-CP4/WP) :Â IP67
- Material : ABS/Polycarbonate/PA6 + Glass Fiber
Model Number | Description | Datasheets & Manuals |
---|---|---|
ZT-CP4 | Zeta CP4 Conventional Weatherproof Manual Call Point, Red | Datasheets |
Dimensions | 8.7 × 8.8 × 2.5 cm |
---|
Related products
-
Zeta Fyreye MkII Conventional Heat Detectors MKII-HF C/W Base
₦17,000.00₦15,000.00Add to cartDESCRIPTION
The Fyreye fixed heat detector (MKII-HF) has a
single thermistor arrangement that gives an alarm at a
temperature of 57°C.
There are 4 types of mounting base available; standard
or deep and with or without diode. -
Gent Interface Programmer for S4 Interfaces on Old Systems (S4-INTERFACE-PROG)
Read moreThe S4-INTERFACE-PROG kit can be used to program the S4-Interface units to simulate legacy 344XX range of interface units. This allows the S4 interface units to be used in place of old interfaces without the need to upgrade or re-commission the system.
-
Gent Flush Manual Call Point (XENS-850) 470 Ohms Glass
Read moreGent XENS-850 Flush Manual Call Point 470 Ohms Glass
Gent Flush Manual Call Point are designed to provide a manual alarm interface to conventional fire alarm control panels. All call points are supplied in the standard red colour and are available in semi-flush mounting or surface mounting options. The manual call points are all with a 470 Ohm resistor and Normally Open contact, complete with glass.
Both break glass, and resettable operating elements can be used in the standard unit by a yellow strip on the element which becomes visible when activated.
With the addition of a hinged transparent cover the element may be protected against accidental operation.
A specialist test key may be inserted into the bottom of the unit to lower the glass and release the micro-switch and thus a full functional test is achieved.
-
Zeta Remote LED Indicators (MKII-RL/C & MKII-RL/W
₦9,500.00Add to cartDESCRIPTION are two models for the Conventional
Remote LED Indicator, a wall type MKII-RL/W
and ceiling mounted type (requires a base)
MKII-RL/C.
Each unit has 2 LEDs that light up to indicate an alarm. It
has the 8 LED appearance to keep it’s family identity.
The MKII-RL/W is supplied with a backbox for surface
mounting. It is also available without backbox for flush
fitting.
Popular Tags
Best offers
Join Risk Free
30 days refund
100% Safe
Secure Shopping
24x7 Support
Online 24 hours
Best Offers
Grab Now
Free Shiping
On all order over
Know Us
Safetech.hub is the newest online platform envisioned to provide 24/7 online platform for integrators, installers, and end users of Extra Low Voltage (ELV) systems in Nigeria
Read More
Reviews
There are no reviews yet.