Robust metal enclosure c/w lift off lid & heavy-duty base connections.
Eight conventional Zone circuits.
Two conventional Sounder circuits.
Separate indicators for open & short circuit fault, sounder fault and battery/power supply fault.
Non-latching class change sounder output, latching fire & non-latching fault outputs (via expansion loom).
Short circuit=fire facility (pre-1980 BS, no resistors in call points, selectable on a zone by zone basis).
Ancillary connections for repeaters & other system add-ons including fault relay modules, fire relay modules, sounder delay relay modules, sounder extender kits, etc).
Multi-lingual variants (subject to quantities).
Space for 2 x 12V 3.2Ah VRLA batteries.
Compatible with virtually all known conventional fire detectors including C-TEC’s ActiV range.
Designed to comply with BS 5839-4 (this panel in not compliant with EN54-2/4 and should NOT be used in new UK or European installations).
A fault isolating module with sounder drive capability designed to meet requirement 17.9.2c of Dutch standard NEN2575.
BSI certified to EN54 parts 17 & 18.
Measures just 55mm x 55mm x 16mm (will fit in the base of most conventional sounders).
Up to 30 BF365IM modules per BF365SC controller.
Allows low-cost, non-fire resistant sounder circuit cabling to be used when used in conjunction with our BF365SC Sounder Isolator Controller (subject to fire officer approval).
Wiring must be made in a loop arrangement, beginning and ending at the controller.
If a wiring fault should occur, the Module(s) nearest to the faulty section of cabling will, if needed, isolate this section. As the Modules are driven from each direction, any loss of cable integrity will have no effect on the functionality of the actual sounders.
Can be used to repeat the functions of a master CFP standard or AlarmSense 2-8 zone fire panel at remote parts of site (e.g. all potential fire service entrances).
Up to 8 repeaters per CFP master.
Includes its own Mains power supply that requires its own standby battery supply.
Provides the user with access to all AL1 and AL2 functions.
Master/Repeater communication achieved using CFP761 network driver cards (one CFP761 is supplied with the Repeater, an additional CF761 card is required at the master CFP).
Communicates over screened two-wire fire resistant cable.
Total repeater network cable length should not exceed 1KM.
Attractive flush or surface mountable plastic lid and enclosure – no bezel required.
A high-quality lockable double pole Fire Alarm Control Panel Mains Keyswitch.
Allows the Mains supply to a fire alarm panel to be switched on or off in accordance with BS 5839-1.
Ideal for use during routine test and maintenance (e.g. battery test, main board replacement etc). Note, if working on the Mains in the panel you must also follow correct practice and isolate the Mains supply at the distribution board.
Fits on a standard UK 47mm flush or surface mount back box.
Supplied with 2 x M3.5 25mm fixing screws.
BS EN60669-1 compliant.
Always read the full installation and operating instructions supplied with the unit before use.
Designed to connect to the RS485 terminals on an EP203 Automatic Extinguisher Panel to provide remote system status indication via a 128 x 64 pixel LCD status display.
Also includes a pull-down manual release button, a mode (auto/manual) keyswitch and a wide range of system status indicators.
Three monitored input connections (Hold, Abort and Mode).
Max. 8 remote status units per EP203 panel.
Surface remote status units (EP210S) and weather proof enclosures (BF359/1) also available.
Designed to connect to the RS485 terminals on an EP203 Automatic Extinguisher Panel to provide remote system status indication via a 128 x 64 pixel LCD status display.
Also includes a pull-down manual release button, a mode (auto/manual) keyswitch and a wide range of system status indicators.
Three monitored input connections (Hold, Abort and Mode).
Max. 8 remote status units per EP203 panel.
Surface remote status units (EP210S) and weather proof enclosures (BF359/1) also available.