C-Tec FP 8 Zone Conventional Fire Alarm Panel-Ff388-2
₦125,000.00₦120,000.00 -
SOCA SL-130 Dead Bolt Lock ( All purpose type )
₦15,000.00₦13,000.00 -
SOCA SL-100D Dead Bolt Lock ( for automatic door)
₦18,000.00₦15,000.00 - SOCA SL 100A Dead Bolt ₦15,000.00
- Soca SD-30 Armored Door Loop
Tag Clouds
Gent 17801-01 Surface Mount Base with Dual Diodes
- Key Features
- Common to all Gent series detectors
- Automatic locking option
- Head out continuity monitoring
- Easy to install
The Gent 17801-01 is a Polar White conventional fire detector base with diode. It allows any Gent 17801-01 conventional detector to be removed or replaced without disconnecting wiring from detector terminals. Detectors plug into the base units with a simple twist and lock action, allowing quick and easy removal for cleaning and servicing, or reselection of detector type should the usage of the protected area change.
Designed for systems complying with the recommendations of Gent 17801-01 where the removal of a detector from its base must not affect the operation of devices wired further down the line, the Gent 17801-01 base includes a diode arrangement providing line continuity. When using the Gent 17801-01 with any conventional control panel for head out monitoring, the line must be terminated with a active end-of-line device.
Robust wiring terminals
Forming an integral part of the overall detector assembly, the base is provided with slots for screw fixing to either surface wiring plates, or conduit boxes with screw fixing centres between 50 and 90 mm.
The Gent 17801-01 features robust wiring terminals with captive clamping washers to ensure secure wiring termination. The bases are of shallow design with ample space to accommodate cables of all types. Terminals are provided inside the moulding for the connection of a remote LED when required.
Automatic locking
In order to prevent the unauthorised removal of a detector from its base, an automatic locking breakout is incorporated into all detector mouldings. When this breakout is removed, detectors can then only be released from their bases by the use of a special tool. The locking facility is an easily applied option often taken on-site at the system commissioning stage.
For systems where head out continuity is not a requirement, the Gent 17801-01 base should be installed.
Related products
-
C-TEC ActiV Conventional Hi-Output W-2.75-9 Wall VAD c/w 100dB(A) Sounder (shallow base) Part No. BF433C/CC/SR
Read more- Third-party certified to EN54-3 (Sounders) and EN54-23 (VADs).
- Provides ‘W-2.75-9’ rated light distribution when wall mounted (min. 0.4 lux over a 2.75Â x 9m cuboid area). Also rated as a W-4-4 VAD.
- Impressive 100dB(A) sound output @ 1m.
- Includes 31 selectable primary tones and an optional secondary tone.
- Two volume levels (high and low)
- Three selectable VAD flash rates (0.5Hz, 1Hz, OFF)
- Alarm Current at 30Vdc =Â 12.2mA (0.5Hz) or 19.5mA (1Hz)
- Alarm Current at 18Vdc =Â 14.5mA (0.5Hz) or 25mA (1Hz)
- IP21C rated.
- Manufactured in the UK by C-TEC.
-
Zeta Fyreye MKII Diode Base
₦1,500.00Add to cartDESCRIPTION
Fyreye MKII Diode Base
Low profile or deep diode mounting base for the Fyreye MKII range of conventional detectors.
-
Gent 4 ZONE CONVENTIONAL PANEL, EN54 LESS BATTERIES (13270-04LB)
₦259,000.00₦235,500.00Add to cartDESCRIPTION
Gent 13270-04LB 4 Zone Conventional Xenex Fire Panel
BSI approved to EN54: Parts 2 & 4, the Xenex control panel can be used on installations meeting BS 5839:Part1. Control panel options for 2-8 zones can be specified.
Designed to simplify system installation, each Xenex panel contains an integral power supply and battery support to drive up to 8 alarm sounder circuits, 2 auxiliary relay contacts, a zone disablement facility and also one-man test and commissioning features.
-
C-TEC ActiV Conventional Base Voice Sounder Part No. BF454C/CC/W
Read more-
-
- Superb sound intelligibility.
- Choose from two evacuation voice messages and four evacuation alarm tones (your selected evacuation message will be preceded by the selected tone).
- Alarm Current at 30Vdc = 10mA.
- Alarm Current at 18Vdc = 8mA.
- Optional BF330CTLIDW white or BF330CTLIDR red cap available for stand-alone use.
- Supplied with a BF431QCP quick connect plate and detector spur wires.
- IP21C rated.
-
-
Popular Tags
Best offers
Join Risk Free
30 days refund
100% Safe
Secure Shopping
24x7 Support
Online 24 hours
Best Offers
Grab Now
Free Shiping
On all order over
Know Us
Safetech.hub is the newest online platform envisioned to provide 24/7 online platform for integrators, installers, and end users of Extra Low Voltage (ELV) systems in Nigeria
Read More
Reviews
There are no reviews yet.