Category
- Uncategorized
- Access Control and Time Attendance System
- Accessories
- Addressable base
- Audio
- Cable
- Call Point
- Cameras
- Closed Circuit Television System (CCTV)
- Computer & Laptop
- Door controller
- Fire Alarm System
- Home Appliances
- Manual Callpoints
- Metal Detector
- Naso mask
- New Arrival
- Night Vision
- On Sale
- Security Alarm System
Popular
-
C-Tec FP 8 Zone Conventional Fire Alarm Panel-Ff388-2
₦125,000.00₦120,000.00 -
SOCA SL-130 Dead Bolt Lock ( All purpose type )
₦15,000.00₦13,000.00 -
SOCA SL-100D Dead Bolt Lock ( for automatic door)
₦18,000.00₦15,000.00 - SOCA SL 100A Dead Bolt ₦15,000.00
- Soca SD-30 Armored Door Loop
Tag Clouds
Zeta Triple IR Flame Detector ZT-30P
-
- Triple IR Spectrum – for longer distance detection and high false alarm immunity
- Compact and lightweight design
- User Selectable (Senitivity/Functions)
- Multiple output options
- Relays for Alarm and Fault
- 0-20mA (stepped)
- RS-485/RS-232 spectrum monitoring
- Lower power requirement (35mA – standby / 75mA – alarm)
- Ex cable gland /2 metre cable assembled & provided for users’ easy installation
- Certifications
- ATEX approved by DNV for explosion-proof
- CE marking
- Certifications
UV/IR & Triple IR (IR3) Flame Detectors
The new range of UV/IR and Triple IR Flame Detectors detect fuel and gas fires at long distances with the highest immunity to false alarms. The ZT-30P and the ZT-20EX can detect a 0.1m2 gasoline pan fire at 30m in less than 5 seconds. The ZT-500EX can detect the same fire at 65m in less than 5 seconds.
New features include RS484/RS232 compatabilities for digital communications; lower power requirements; and a compact, lighter design. ZT-20EX and ZT-500EX series are approved to ATEX by DNV for explosion-proof.
Technical Specification
- Response Time:Â Typically 5 seconds
- Adjustable Time Delay:Â Up to 20 seconds
- Sensitvity Range:Â 4 sensitivity ranges for 0.1m2 n-Heptane pan fire from 15m to 65m
- Field of View: Horizontal / Vertically Typical 120º & 120º Max
- Built-in-Test:Â Automatic self-check to verify the lens cleanliness/ electronic circuits & etc
- Temperature Range: Operating/Storage:-40ºC to 75ºC
- Humidity:Â Up to 95% non-condensing
- Operating Voltage:Â 24VDC nominal (18-32VDC)
- Power Consumption:Â Standby: max. 50mA, Alarm: max. 70mA
- Cable Entry: 1 x Ø6mm
- Wiring:Â According to the requirements
- Electromagnetic Compatibility:Â Complies with EN 61000-6-4 and EN 50130-4
- Electrical Interface:Â 4-Wiring relay contact outputs
- Relays:Â Alarm(N.O.), Fault(N.C) SPST volt-free contacts rated 5A at 30VDC or 250VAC
- RS-485 (option):Â RS-485 Modbus compatible communication link that can be used in computer controlled installations
- Materials:Â Heavy duty copper free aluminium with white powder coating
- Mounting (Tilt Mount):Â Heavy duty copper free aluminium with white powder coating
- Dimensions:Â Detector 63(D) x 110 (L) mm
- Weight:Â Detector & Mouting Bracket (Aluminium): 0.3kg
- Water and Dust:Â IP65
- EMI/RFI:Â EN61000
- Performance:Â Designed to meet FM3260 (EN54-10)
ZT-30P | Zeta Triple IR Flame Detector | Datasheet Manual |
Dimensions | 6.3 × 11.0 cm |
---|
Related products
-
APOLLO INTELLIGENT MANUAL CALL POINT – ORANGE (SA5900-907APO)
Read moreThe Manual Call Point is commonly used to manually control smoke vent systems.
- Resettable operating element
- 170° viewable LED
- Suitable for semi flush or surface mounting
- ‘Plug and Play’ terminal connections for faster wiring
- Continuity link for wiring test before commissioning
- XP95, Discovery and CoreProtocol compatible
-
APOLLO ISOLATOR – NEGATIVE 55000-720APO
Read moreThe Isolator is placed at intervals on the loop and ensures that, in the case of a short circuit, only the section between the isolators will be affected. When the short-circuit is removed, the isolators automatically restore power and data to the isolated section
- Detects wiring short-circuits
- Minimises disruption from short-circuits
- Automatic de-isolation on the short-circuit removal
-
APOLLO XP95 HEAT DETECTOR (A2S) 55000-400APO
₦28,000.00₦24,500.00Add to cartThe XP95 Heat Detector (A2S) monitors temperature by using a single thermistor which provides a count output proportional to the external air temperature, reporting an alarm at 55°C.
- Reliable fire detection in areas with a wide temperature range from -20°C to +70°C
- Ideal for environments that are dirty or smoky under normal circumstances
- Unaffected by wind and atmospheric pressure
-
APOLLO INTELLIGENT MANUAL CALL POINT – RED (SA5900-908APO)
Read moreThe Manual Call Point is used to manually initiate an alarm signal on the fire detection system.
- EN 54-11 & EN 54-17 Certified
- Resettable operating element
- 170° viewable LED
- Suitable for semi flush or surface mounting
- ‘Plug and Play’ terminal connections for faster wiring
- Continuity link for wiring test before commissioning
- XP95, Discovery and CoreProtocol compatible
Popular Tags
Best offers
Join Risk Free
30 days refund
100% Safe
Secure Shopping
24x7 Support
Online 24 hours
Best Offers
Grab Now
Free Shiping
On all order over
Know Us
Safetech.hub is the newest online platform envisioned to provide 24/7 online platform for integrators, installers, and end users of Extra Low Voltage (ELV) systems in Nigeria
Read More
Reviews
There are no reviews yet.